The refractive accuracy between topographic keratometry and biometric keratometry for extended depth-of-focus intraocular lens implantation

被引:0
|
作者
Lee, Chia-Yi [1 ,2 ,3 ]
Yang, Shun-Fa [1 ,4 ]
Chen, Hung-Chi [5 ,6 ,7 ]
Lian, Ie-Bin [8 ]
Huang, Jing-Yang [4 ]
Chang, Chao-Kai [2 ,9 ]
机构
[1] Chung Shan Med Univ, Inst Med, Taichung, Taiwan
[2] Nobel Eye Inst, 13-5 Gongyuan Rd, Taipei 100008, Taiwan
[3] Jen Ai Hosp, Dept Ophthalmol, Dali Branch, Taichung, Taiwan
[4] Chung Shan Med Univ Hosp, Dept Med Res, Taichung, Taiwan
[5] Chang Gung Mem Hosp, Dept Ophthalmol, Linkou, Taiwan
[6] Chang Gung Mem Hosp, Ctr Tissue Engn, Linkou, Taiwan
[7] Chang Gung Univ, Dept Med, Coll Med, Taoyuan, Taiwan
[8] Natl Changhua Univ Educ, Inst Stat & Informat Sci, Changhua, Taiwan
[9] Yuanpei Univ Med Technol, Dept Optometry, Hsinchu, Taiwan
来源
关键词
extended depth-of-focus; topographic; biometric; astigmatism; angle kappa; ASTIGMATISM; POWER;
D O I
10.7150/ijms.99907
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To investigate the influence of different keratometry (K) measurements on the postoperative outcomes of cataract surgery with extended depth-of-focus (EDOF) intraocular lens (IOL) implantation. Methods: A retrospective cohort study was conducted, and patients who received cataract surgery and one type of EDOF IOL implantation were included. The patients were then categorized according to K measurements, and 70 and 30 eyes were included in the biometric-K and topographic-K groups, respectively. The primary outcomes were postoperative uncorrected distance visual acuity (UDVA), spherical equivalent (SE) and cylinder power. A generalized linear model was applied to compare the adjusted odds ratios (aORs) and 95% confidence intervals (CIs) of the outcomes between groups. Results: One month after surgery, the UDVA was 0.15 and 0.07 in the biometric-K group and topographic-K group, respectively. Furthermore, the final SEs were -0.42 D and -0.13 D in the biometric-K group and topographic-K group, respectively, and the final cylinder powers were -0.35 D and -0.13 D in the biometric-K group and topographic-K group, respectively. According to the multivariate analysis, the topographic-K group presented a significantly better UDVA (P = 0.044) and significantly lower cylinder power (P = 0.031) than the biometric-K group. Angle kappa was significantly correlated with high postoperative astigmatism in the topographic-K group (P = 0.033), whereas angle kappa, steep K, and corneal cylinder powers were significantly correlated with high postoperative astigmatism in the biometric-K group (all P < 0.05). Conclusion: Topography-based K measurements yielded better refractive outcomes than biometric-based K measurements did.
引用
收藏
页码:2912 / 2918
页数:7
相关论文
共 50 条
  • [1] Comparing prediction accuracy between total keratometry and conventional keratometry in cataract surgery with refractive multifocal intraocular lens implantation
    Chung, Ho Seok
    Chung, Jae Lim
    Kim, Young Jun
    Lee, Hun
    Kim, Jae Yong
    Tchah, Hungwon
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Comparing prediction accuracy between total keratometry and conventional keratometry in cataract surgery with refractive multifocal intraocular lens implantation
    Ho Seok Chung
    Jae Lim Chung
    Young Jun Kim
    Hun Lee
    Jae Yong Kim
    Hungwon Tchah
    Scientific Reports, 11
  • [3] Errors in keratometry for intraocular lens implantation in children
    Meittelviefhaus, H
    Gentner, C
    OPHTHALMOLOGE, 2000, 97 (03): : 186 - 188
  • [4] Effect of Posterior Keratometry on the Accuracy of 10 Intraocular Lens Calculation Formulas: Standard Keratometry versus Total Keratometry
    Jin, Aixia
    Zhang, Jiaqing
    Tan, Xuhua
    Jin, Kangxin
    Zhang, Yifan
    Han, Xiaotong
    Chen, Xiaoyun
    Jin, Guangming
    Luo, Lixia
    Liu, Yizhi
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (06) : 1829 - 1838
  • [5] Visual, Refractive, Functional, and Patient Satisfaction Outcomes After Implantation of a New Extended Depth-of-Focus Intraocular Lens
    Gil, Javier Ferrando
    Irazola, Adela Churruca
    Reparaz, Iraia
    Lauzirika, Gorka
    Martinez-Soroa, Itziar
    Mendicute, Javier
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 3801 - 3813
  • [6] Effect of Posterior Keratometry on the Accuracy of 10 Intraocular Lens Calculation Formulas: Standard Keratometry versus Total Keratometry
    Aixia Jin
    Jiaqing Zhang
    Xuhua Tan
    Kangxin Jin
    Yifan Zhang
    Xiaotong Han
    Xiaoyun Chen
    Guangming Jin
    Lixia Luo
    Yizhi Liu
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 1829 - 1838
  • [7] Prediction accuracy of no-history intraocular lens formulas for a diffractive extended depth-of-focus intraocular lens after myopic corneal refractive surgery
    Tan, Qian
    Wang, Yong
    Zhao, Libei
    Peng, Manqiang
    Zheng, Hansong
    Lin, Ding
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (04): : 462 - 468
  • [8] Visual Performances of a New Extended Depth-of-Focus Intraocular Lens with a Refractive Design: A Prospective Study After Bilateral Implantation
    Spadea, Leopoldo
    Giannico, Maria Ilaria
    Formisano, Martina
    Alisi, Ludovico
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2021, 17 : 727 - 738
  • [9] Functional assessment of a new extended depth-of-focus intraocular lens
    Savini, Giacomo
    Balducci, Nicole
    Carbonara, Claudio
    Rossi, Scipione
    Altieri, Manuel
    Frugis, Nicola
    Zappulla, Emilia
    Bellucci, Roberto
    Alessio, Giovanni
    EYE, 2019, 33 (03) : 404 - 410
  • [10] Functional assessment of a new extended depth-of-focus intraocular lens
    Giacomo Savini
    Nicole Balducci
    Claudio Carbonara
    Scipione Rossi
    Manuel Altieri
    Nicola Frugis
    Emilia Zappulla
    Roberto Bellucci
    Giovanni Alessio
    Eye, 2019, 33 : 404 - 410