Agreement in Biometric Parameters Between Swept-Source-Optical Coherence Tomography and Optical Low-Coherence Interferometry: Insights into Clinical Precision

被引:0
|
作者
Munteanu, Mihnea [1 ,2 ]
Al Barri, Leila [1 ]
Stanca, Simona [3 ]
Mocanu, Valeria [1 ,2 ]
Rosca, Cosmin [1 ]
Balica, Nicolae-Constantin [4 ]
Stanca, Horia T. [5 ]
机构
[1] Victor Babes Univ Med & Pharm, Ophthalmol Dept, Timisoara 300041, Romania
[2] Victor Babes Univ Med & Pharm, Oftalmo Sensory Tumor Res Ctr ORL EYE ENT, Timisoara 300041, Romania
[3] Carol Davila Univ Med & Pharm, Pediat Dept, Bucharest 020022, Romania
[4] Victor Babes Univ Med & Pharm, ENT Dept, Timisoara 300041, Romania
[5] Carol Davila Univ Med & Pharm, Ophthalmol Dept, Bucharest 050474, Romania
关键词
swept-optical coherence tomography; optical low-coherence interferometry; biometric measurements; axial length; keratometry; astigmatism; anterior chamber depth; clinical application; SOURCE OCT; REPEATABILITY; EFFICIENCY;
D O I
10.3390/jcm14051407
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Accurate biometric measurements are critical for achieving optimal refractive outcomes in cataract surgery. This study evaluated the agreement of biometric measurements between a swept-source optical coherence tomography (SS-OCT) biometer (Argos (R), Movu Inc.) and an optical low-coherence interferometry (OLCI) biometer (Aladdin (R), Topcon Corp.). Parameters analyzed included axial length (AL), anterior chamber depth (ACD), lens thickness (LT), keratometry (K1, K2), and white-to-white corneal diameter (WTW). Methods: A total of 170 eyes were examined, and agreement was assessed using Bland-Altman analysis, intraclass correlation coefficients (ICCs), and Pearson correlation coefficients. Results: Excellent agreement was observed for AL (ICC = 0.975), ACD (ICC = 0.960), LT (ICC = 0.951), K1 (ICC = 0.921), and K2 (ICC = 0.927). Moderate agreement was found for astigmatism axis (ICC = 0.655) and cylinder power (ICC = 0.891). Poor agreement was noted for astigmatism-related Jackson cross-cylinder vectors J0 (ICC = 0.334) and J45 (ICC = -0.311), as well as for WTW (ICC = 0.338). Bland-Altman plots demonstrated narrow limits of agreement for most parameters, with mean differences of 0.009 mm for AL and 0.06 mm for ACD. Conclusions: Both devices demonstrated high degrees of agreement for core biometric parameters, supporting their clinical interchangeability. However, the variability in WTW and astigmatism-related measurements highlights the need for caution when precise corrections are required.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Swept source optical coherence tomography and optical coherence tomography angiography in central serous chorioretinopathy
    Hager, Ben Amor
    Namsia, Walid
    Yasmine, Walha
    Arije, Jouini
    Eya, Essassi
    Sana, Khochtali
    Moncef, Khairallah
    ACTA OPHTHALMOLOGICA, 2024, 102
  • [32] Clinical Observation of Choroidal Osteoma Using Swept-Source Optical Coherence Tomography and Optical Coherence Tomography Angiography
    Xuan, Yi
    Chang, Qing
    Zhang, Yongjin
    Ye, Xiaofeng
    Liu, Wei
    Li, Lei
    Wang, Keyan
    Zhou, Jian
    Wang, Min
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [33] DESIGN OF A PRECISION OPTICAL LOW-COHERENCE REFLECTOMETER
    BOOSTER, DH
    CHOU, H
    HART, MG
    MIFSUD, SJ
    RAWSON, RF
    HEWLETT-PACKARD JOURNAL, 1993, 44 (01): : 39 - &
  • [34] Ocular measurements of a swept-source biometer: Repeatability data and comparison with an optical low-coherence interferometry biometer
    Nemeth, Gabor
    Modis, Laszlo, Jr.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 789 - 797
  • [35] Comparison of ocular biometric parameters between two swept-source optical coherence tomography devices and Scheimpflug tomography in patients with cataract
    Ma, Shan
    Li, Cheng
    Sun, Jing
    Yang, Jun
    Wen, Kai
    Chen, Xi-Teng
    Zhao, Fang-Yu
    Gao, Rong-Yu
    Tian, Fang
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (08) : 1437 - 1446
  • [36] Measurement agreement between a new biometer based on partial coherence interferometry and a validated biometer based on optical low-coherence reflectometry
    Li, Junhua
    Chen, Hao
    Savini, Giacomo
    Lu, Weicong
    Yu, Xinxin
    Bao, Fangjun
    Wang, Qinmei
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 68 - 75
  • [37] Comparing Predictive Accuracy of a Swept Source Optical Coherence Tomography Biometer and an Optical Low Coherence Reflectometry Biometer
    Blehm, Clayton
    Hall, Brad
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 2125 - 2131
  • [38] Comparison of Clinical Outcomes between Swept-source Optical Coherence Tomography Biometer and Partial Coherence Interferometer
    Jang, Mirinae
    Lee, Hye Jin
    Lee, Sang-Yoon
    Kim, Jin Young
    Ma, Dae Joong
    Jeong, Jin Ho
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (08): : 905 - 910
  • [39] Optical low-coherence interferometry for selected technical applications
    Plucinski, J.
    Hypszer, R.
    Wierzba, P.
    Strakowski, M.
    Jedrzejewska-Szczerska, M.
    Maciejewski, M.
    Kosmowski, B. B.
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2008, 56 (02) : 155 - 172
  • [40] Clinical investigation of human eye by swept source optical coherence tomography
    Yasuno, Yoshiaki
    2007 PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1-4, 2007, : 171 - 172