Agreement in Biometric Parameters Between Swept-Source-Optical Coherence Tomography and Optical Low-Coherence Interferometry: Insights into Clinical Precision

被引:0
|
作者
Munteanu, Mihnea [1 ,2 ]
Al Barri, Leila [1 ]
Stanca, Simona [3 ]
Mocanu, Valeria [1 ,2 ]
Rosca, Cosmin [1 ]
Balica, Nicolae-Constantin [4 ]
Stanca, Horia T. [5 ]
机构
[1] Victor Babes Univ Med & Pharm, Ophthalmol Dept, Timisoara 300041, Romania
[2] Victor Babes Univ Med & Pharm, Oftalmo Sensory Tumor Res Ctr ORL EYE ENT, Timisoara 300041, Romania
[3] Carol Davila Univ Med & Pharm, Pediat Dept, Bucharest 020022, Romania
[4] Victor Babes Univ Med & Pharm, ENT Dept, Timisoara 300041, Romania
[5] Carol Davila Univ Med & Pharm, Ophthalmol Dept, Bucharest 050474, Romania
关键词
swept-optical coherence tomography; optical low-coherence interferometry; biometric measurements; axial length; keratometry; astigmatism; anterior chamber depth; clinical application; SOURCE OCT; REPEATABILITY; EFFICIENCY;
D O I
10.3390/jcm14051407
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Accurate biometric measurements are critical for achieving optimal refractive outcomes in cataract surgery. This study evaluated the agreement of biometric measurements between a swept-source optical coherence tomography (SS-OCT) biometer (Argos (R), Movu Inc.) and an optical low-coherence interferometry (OLCI) biometer (Aladdin (R), Topcon Corp.). Parameters analyzed included axial length (AL), anterior chamber depth (ACD), lens thickness (LT), keratometry (K1, K2), and white-to-white corneal diameter (WTW). Methods: A total of 170 eyes were examined, and agreement was assessed using Bland-Altman analysis, intraclass correlation coefficients (ICCs), and Pearson correlation coefficients. Results: Excellent agreement was observed for AL (ICC = 0.975), ACD (ICC = 0.960), LT (ICC = 0.951), K1 (ICC = 0.921), and K2 (ICC = 0.927). Moderate agreement was found for astigmatism axis (ICC = 0.655) and cylinder power (ICC = 0.891). Poor agreement was noted for astigmatism-related Jackson cross-cylinder vectors J0 (ICC = 0.334) and J45 (ICC = -0.311), as well as for WTW (ICC = 0.338). Bland-Altman plots demonstrated narrow limits of agreement for most parameters, with mean differences of 0.009 mm for AL and 0.06 mm for ACD. Conclusions: Both devices demonstrated high degrees of agreement for core biometric parameters, supporting their clinical interchangeability. However, the variability in WTW and astigmatism-related measurements highlights the need for caution when precise corrections are required.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Master/slave interferometry - ideal tool for coherence revival swept source optical coherence tomography
    Bradu, Adrian
    Rivet, Sylvain
    Podoleanu, Adrian
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (07): : 2453 - 2468
  • [22] Low-coherence optical fibre speckle interferometry
    Balboa, I.
    D Ford, H.
    Tatam, R. P.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (04) : 605 - 616
  • [23] Correlation of Choroidal Thickness and Volume Measurements with Axial Length and Age Using Swept Source Optical Coherence Tomography and Optical Low-Coherence Reflectometry
    Michalewski, Janusz
    Michalewska, Zofia
    Nawrocka, Zofia
    Bednarski, Maciej
    Nawrocki, Jerzy
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [24] Comparison of Ocular Biometric Measurements Using New Swept-source Optical-coherence Tomography, Low-coherence Reflectometry, A-Scan Biometry, and Autokeratometry
    Cho, Jae Jin
    Bae, Gi Hyun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (04): : 287 - 295
  • [25] Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
    Shu, Bao
    Bao, Fangjun
    Savini, Giacomo
    Lu, Weicong
    Tu, Ruixue
    Chen, Haisi
    Song, Benhao
    Wang, Qinmei
    Huang, Jinhai
    EYE AND VISION, 2020, 7 (01)
  • [26] Swept Source Optical Coherence Tomography: a Review
    Yasin Alibhai A.
    Or C.
    Witkin A.J.
    Current Ophthalmology Reports, 2018, 6 (1) : 7 - 16
  • [27] Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
    Bao Shu
    Fangjun Bao
    Giacomo Savini
    Weicong Lu
    Ruixue Tu
    Haisi Chen
    Benhao Song
    Qinmei Wang
    Jinhai Huang
    Eye and Vision, 7
  • [28] Blood flow pattern in a choroidal hemangioma imaged on swept-source-optical coherence tomography angiography
    Takkar, Brijesh
    Azad, Shorya
    Shakrawal, Jyoti
    Gaur, Nripen
    Venkatesh, Pradeep
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (11) : 1240 - 1242
  • [29] Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer
    Dominguez-Vicent, Alberto
    Venkataraman, Abinaya Priya
    Dalin, Amanda
    Brautaset, Rune
    Montes-Mico, Robert
    EYE AND VISION, 2023, 10 (01)
  • [30] Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer
    Alberto Domínguez-Vicent
    Abinaya Priya Venkataraman
    Amanda Dalin
    Rune Brautaset
    Robert Montés-Micó
    Eye and Vision, 10