Development and Validation of Targeted Metabolomics Methods Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) for the Quantification of 235 Plasma Metabolites

被引:0
|
作者
Xu, Kangkang [1 ,2 ,3 ]
Berthiller, Franz [1 ,2 ]
Metzler-Zebeli, Barbara U. [2 ,4 ]
Schwartz-Zimmermann, Heidi E. [1 ,2 ]
机构
[1] BOKU Univ, Inst Bioanalyt & Agrometabol, Dept Agr Sci, A-3430 Tulln, Austria
[2] Christian Doppler Lab Innovat Gut Hlth Concepts Li, A-1210 Vienna, Austria
[3] Austrian Competence Ctr Feed & Food Qual Safety &, A-3430 Tulln, Austria
[4] Univ Vet Med, Dept Biomed Sci, Unit Nutr Physiol, Vet Pl 1, A-1210 Vienna, Austria
来源
MOLECULES | 2025年 / 30卷 / 03期
关键词
metabolomics; plasma metabolites; targeted HPLC-MS/MS methods; HILIC; reversed-phase high-performance liquid chromatography; animal metabolomics; HIGH-THROUGHPUT; STRATEGIES; BIOMARKER;
D O I
10.3390/molecules30030706
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Plasma contains metabolites with diverse physicochemical properties, ranging from highly polar to highly apolar, and concentrations spanning at least nine orders of magnitude. Plasma metabolome analysis is valuable for monitoring health and evaluating medical interventions but is challenging due to the metabolome's diversity and complexity. This study aims to develop and validate targeted LC-MS/MS methods for quantifying 235 mammalian metabolites from 17 compound classes in porcine plasma without prior derivatization. Utilizing reversed-phase and hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry, each analyte is identified and quantified using two selected reaction monitoring (SRM) transitions. Fast polarity switching and scheduled SRM enhance the metabolome coverage and throughput, enabling the analysis of one sample in about 40 min. A simple "dilute and shoot" sample preparation protocol was employed, with samples injected at two dilution levels to align metabolite concentrations within calibration curve ranges. Validation in porcine plasma included assessments of carryover, linearity, detection and quantification limits, repeatability and recovery. The method was further applied to plasma samples from various animal species, demonstrating its applicability to human and animal studies. This study establishes two robust LC-MS/MS methods for comprehensive porcine plasma metabolome quantification, advancing large-scale targeted metabolomics in biomedical research.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the quantification of oximes in KIKO mouse plasma
    Walker, Katie A.
    Vignola, Justin N.
    Rudd, Trinity K.
    Cadieux, C. Linn
    Ditargiani, Robert C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2025, 1251
  • [2] Quantification of cyclizine and norcyclizine in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Jensen, Berit Packert
    Vella-Brincat, Jane Winifred Ann
    Begg, Evan James
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (9-10): : 605 - 609
  • [3] Development and validation of bexarote by bioanalytical methods using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)
    K. Nagaraju
    Y. A. Chowdary
    M. V. Basaveswara Rao
    Future Journal of Pharmaceutical Sciences, 7
  • [4] Development and validation of bexarote by bioanalytical methods using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)
    Nagaraju, K.
    Chowdary, Y. A.
    Rao, M. V. Basaveswara
    FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 7 (01)
  • [5] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of voriconazole in human cerebrospinal fluid
    Dong, Liuhan
    Bai, Nan
    Wang, Tianlin
    Cai, Yun
    ANALYTICAL METHODS, 2021, 13 (39) : 4585 - 4593
  • [6] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of tigecycline in rat brain tissues
    Munyeza, Chiedza F.
    Shobo, Adeola
    Baijnath, Sooraj
    Bratkowska, Dominika
    Naiker, Suhashni
    Bester, Linda A.
    Singh, Sanil D.
    Maguire, Glenn E. M.
    Kruger, Hendrik G.
    Naicker, Tricia
    Govender, Thavendran
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (06) : 837 - 845
  • [7] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay to quantify serum voriconazole
    Mak, Justin
    Sujishi, Kirk K.
    French, Deborah
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 986 : 94 - 99
  • [8] Quantification of psilocin in human whole blood using liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Gomonit, Munchelou M.
    Skillman, Britni
    Swortwood, Madeleine J.
    JOURNAL OF FORENSIC SCIENCES, 2024, 69 (02) : 678 - 687
  • [9] ESTIMATION OF MELOXICAM IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY (LC-MS/MS)
    Ganesh, Mani
    Hemalatha, Pushparaj
    Peng, Mei Mei
    Sakthimanigandan, Kalaimani
    Jang, Hyun Tae
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (07) : 867 - 880
  • [10] Quantification of Amino Acids in Plasma by High-Performance Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
    Panaskar, Shrimant N.
    Singh, Susheel K.
    CHROMATOGRAPHIA, 2023, 86 (07) : 567 - 572