Prospective Evaluation of Accelerated Brain MRI Using Deep Learning-Based Reconstruction: Simultaneous Application to 2D Spin-Echo and 3D Gradient-Echo Sequences

被引:0
|
作者
Choi, Kyu Sung [1 ,2 ]
Park, Chanrim [1 ,4 ]
Lee, Ji Ye [1 ,2 ]
Lee, Kyung Hoon [1 ,5 ]
Jeon, Young Hun [1 ]
Hwang, Inpyeong [1 ,2 ]
Yoo, Roh Eul [1 ,2 ]
Yun, Tae Jin [1 ,2 ]
Lee, Mi Ji [3 ]
Jung, Keun-Hwa [3 ]
Kang, Koung Mi [1 ,2 ,6 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Dept Neurol, Seoul, South Korea
[4] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul, South Korea
[5] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Sch Med, Dept Radiol, Seoul, South Korea
[6] Seoul Natl Univ, Seoul Natl Univ Hosp, Coll Med, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
基金
新加坡国家研究基金会;
关键词
Deep learning; Artifacts; Signal-to-noise ratio; Image reconstruction; Volumetric analysis; ITERATIVE RECONSTRUCTION;
D O I
10.3348/kjr.2024.0653
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To prospectively evaluate the effect of accelerated deep learning-based reconstruction (Accel-DL) on improving brain magnetic resonance imaging (MRI) quality and reducing scan time compared to that in conventional MRI. Materials and Methods: This study included 150 participants (51 male; mean age 57.3 +/- 16.2 years). Each group of 50 participants was scanned using one of three 3T scanners from three different vendors. Conventional and Accel-DL MRI images were obtained from each participant and compared using 2D T1- and T2-weighted and 3D gradient-echo sequences. Accel-DL acquisition was achieved using optimized scan parameters to reduce the scan time, with the acquired images reconstructed using U-Net-based software to transform low-quality, undersampled k-space data into high-quality images. The scan times of Accel-DL and conventional MRI methods were compared. Four neuroradiologists assessed the overall image quality, structural delineation, and artifacts using Likert scale (5- and 3-point scales). Inter-reader agreement was assessed using Fleiss' kappa coefficient. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and volumetric quantification of regional structures and white matter hyperintensities (WMHs) was performed. Results: Accel-DL showed a mean scan time reduction of 39.4% (range, 24.2%-51.3%). Accel-DL improved overall image quality (3.78 +/- 0.71 vs. 3.36 +/- 0.61, P < 0.001), structure delineation (2.47 +/- 0.61 vs. 2.35 +/- 0.62, P < 0.001), and artifacts (3.73 +/- 0.72 vs. 3.71 +/- 0.69, P = 0.016). Inter-reader agreement was fair to substantial (kappa = 0.34-0.50). SNR and CNR increased in Accel-DL (82.0 +/- 23.1 vs. 31.4 +/- 10.8, P = 0.02; 12.4 +/- 4.1 vs. 4.4 +/- 11.2, P = 0.02). Bland-Altman plots revealed no significant differences in the volumetric measurements of 98.2% of the relevant regions, except in the deep gray matter, including the thalamus. Five of the six lesion categories showed no significant differences in WMH segmentation, except for leukocortical lesions (r = 0.64 +/- 0.29). Conclusion: Accel-DL substantially reduced the scan time and improved the quality of brain MRI in both spin-echo and gradient- echo sequences without compromising volumetry, including lesion quantification.
引用
收藏
页码:54 / 64
页数:11
相关论文
共 50 条
  • [41] High-resolution MR cisternography of the cerebellopontine angle: 2D versus 3D fast spin-echo sequences
    Iwayama, E
    Naganawa, S
    Ito, T
    Fukatsu, H
    Ikeda, M
    Ishigaki, T
    Ichinose, N
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (05) : 889 - 895
  • [42] 3D zero-echo time and 3D T1-weighted gradient-echo MRI sequences as an alternative to CT for the evaluation of the lumbar facet joints and lumbosacral transitional vertebrae
    Kaniewska, Malwina
    Kuhn, Daniel
    Deininger-Czermak, Eva
    Wolharn, Lucas
    Finkenstaedt, Tim
    Guggenberger, Roman
    ACTA RADIOLOGICA, 2023, 64 (06) : 2137 - 2144
  • [43] A three-point Dixon method for water and fat separation using 2D and 3D gradient-echo techniques
    Wang, Y
    Li, DB
    Haacke, EM
    Brown, JJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03): : 703 - 710
  • [44] Comparison of 3D versus 2D Fast Spin-Echo Imaging for Evaluation of Articular Cartilage in the Knee on a 3 Tesla System
    Haims, A.
    Milewski, M.
    Essig, D.
    Medvecky, M.
    Katz, L.
    Moukaddam, H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [45] Diagnostic value of 3D T1-weighted gradient-echo and 2D T1-weighted in-phase and out-of-phase gradient-echo sequences for appendicitis diagnosis in pregnant women
    Hung, Nguyen Duy
    Dung, Le Thanh
    Dung, Nguyen-Thi Kim
    Ha Khuong, Nguyen
    Anh, Nguyen Hai
    Duc, Nguyen Minh
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2023, 13 : 1 - 6
  • [46] Fast-spin-echo versus rapid gradient-echo for 3D magnetization-prepared acquisitions: Application to inhomogeneous magnetization transfer
    Taso, Manuel
    Munsch, Fanny
    Girard, Olivier M.
    Duhamel, Guillaume
    Alsop, David C.
    Varma, Gopal
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (02) : 550 - 564
  • [47] Comparison of 3D Isotropic Resolution Fast Spin-Echo MRI with Conventional 2D MRI of Knee Ligaments and Menisci at 3.0T
    Subhas, N.
    Kao, A.
    Freire, M.
    Polster, J.
    Obuchowski, N.
    Winalski, C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [48] Stomach diseases: MR evaluation using combined T2-weighted single-shot echo train spin-echo and gadolinium-enhanced spoiled gradient-echo sequences
    Marcos, HB
    Semelka, RC
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (06): : 950 - 960
  • [49] 2D AND 3D HIGH-RESOLUTION GRADIENT-ECHO FUNCTIONAL IMAGING OF THE BRAIN - VENOUS CONTRIBUTIONS TO SIGNAL IN MOTOR CORTEX STUDIES
    HAACKE, EM
    HOPKINS, A
    LAI, S
    BUCKLEY, P
    FRIEDMAN, L
    MELTZER, H
    HEDERA, P
    FRIEDLAND, R
    KLEIN, S
    THOMPSON, L
    DETTERMAN, D
    TKACH, J
    LEWIN, JS
    NMR IN BIOMEDICINE, 1994, 7 (1-2) : 54 - 62
  • [50] Qualitative and quantitative assessment of wrist MRI at 3.0T: comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo
    Jung, Jee Young
    Yoon, Young Cheol
    Jung, Jin Young
    Choe, Bong-Keun
    ACTA RADIOLOGICA, 2013, 54 (03) : 284 - 291