Skin dose estimation of Multani Mitti (Fuller's earth) using Geant4 Monte Carlo simulations

被引:0
|
作者
Satti, Khizar Hayat [1 ,2 ]
Siddique, Muhammad Tariq [1 ]
Rehman, Shakeel Ur [1 ]
Dilband, Muhammad [2 ]
机构
[1] Pakistan Inst Engn & Appl Sci, Dept Phys & Appl Math, Islamabad, Pakistan
[2] Pakistan Inst Nucl Sci & Technol, Hlth Phys Div, Islamabad, Pakistan
关键词
Multani mitti; Gamma spectrometry; Geant4; Skin dose; BASAL LAYER; CLAY; CONTAMINATION; ACTIVATION; EPIDERMIS; ELEMENTS;
D O I
10.1016/j.radphyschem.2024.112353
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study is aimed to estimate the skin dose due to presence of natural radionuclides in the Multani Mitti (MM, fuller's earth). The activity concentration of natural radionuclides is measured by using Canberra's HPGe detector model GC3020. The average activity concentration levels of 238U, 232Th and 40K are found to be 47, 71 and 748 Bq kg- 1 respectively which are higher than corresponding world's median values 30, 35 and 400 Bq kg- 1 as reported in Unscear 2000. Geant4 MC simulation is used to estimate skin doses arising due to application of MM on the skin. The decay chains for 238U and 232Th are simulated using Radioactive Decay Module (RDM) available in the Geant4, which automatically accounts for the all members of the decay chain and all types of radioactive emissions. The skin dose conversion factors for natural radionuclides in MM for 238U,232Th and 40K are found to be 0.5, 0.5 and 330 mGy MBq- 1 hr- 1. The main contribution to skin dose comes from 40K. The radiological health risks to miners and workers are evaluated by measuring radium equivalent activity, radiation hazard indices, annual absorbed dose rate, annual gonadal effective dose equivalent and annual effective dose equivalent. The values of annual absorbed dose rate, gonadal dose and annual effective dose equivalent are found higher than world's median values in the soil. Therefore, miners and workers dealing with MM are vulnerable to potential negative health effects of radiation exposure.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Geant4 Based Monte Carlo Dose Calculation Engine for Radiation Therapy
    Xiao, Shanjie
    Yang, Xue
    Sztejnberg, Manuel
    Jevremovic, Tatjana
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (02) : 775 - 781
  • [22] Adaptation of GEANT4 to Monte Carlo dose calculations based on CT data
    Jiang, H
    Paganetti, H
    MEDICAL PHYSICS, 2004, 31 (10) : 2811 - 2818
  • [23] GMC: a GPU implementation of a Monte Carlo dose calculation based on Geant4
    Jahnke, Lennart
    Fleckenstein, Jens
    Wenz, Frederik
    Hesser, Juergen
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05): : 1217 - 1229
  • [24] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit REPLY
    Cai, Zhongli
    Pignol, Jean-Philippe
    Chan, Conrad
    Reilly, Raymond M.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) : 1489 - 1489
  • [25] The Effect of Beam Polarization in Microbeam Radiation Therapy (MRT): Monte Carlo Simulations Using Geant4
    Spiga, J.
    Prezado, Y.
    Braeuer-Krisch, E.
    Fanti, V.
    Randaccio, P.
    Bravin, A.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2170 - +
  • [26] Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields
    Gholami, Somayeh
    Longo, Francesco
    Nedaie, Hassan Ali
    Berti, Alessio
    Mousavi, Mehdi
    Meigooni, Ali S.
    MEDICAL DOSIMETRY, 2018, 43 (03) : 214 - 223
  • [27] IMRT treatment Monitor Unit verification using absolute calibrated BEAMnrc and Geant4 Monte Carlo simulations
    Oborn, B. M.
    Williams, M.
    Bailey, M.
    Carolan, M. G.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [28] Investigation of Perylene as a Converter Material for Fast Neutron Detection and Spectroscopy Using GEANT4 Monte Carlo Simulations
    Tripathi, Shivang
    Upadhyay, Chandrakant
    Nagaraj, C. P.
    Venkatesan, A.
    Devan, K.
    Madhusoodanan, K.
    ADVANCES IN SYSTEMS, CONTROL AND AUTOMATION, 2018, 442 : 189 - 197
  • [29] Applications of the Monte Carlo method in nuclear physics using the GEANT4 toolkit
    Moralles, Mauricio
    Guimaraes, Carla C.
    Bonifacio, Daniel A. B.
    Okuno, Emico
    Murata, Helio M.
    Bottaro, Marcio
    Menezes, Mario O.
    Guimaraes, Valdir
    NUCLEAR PHYSICS 2008: XXXI WORKSHOP ON NUCLEAR PHYSICS IN BRAZIL, 2009, 1139 : 51 - +
  • [30] Comparison of Monte Carlo simulations based on Geant4 and Fluka to the TileCal test beam data
    Cascella, M.
    Gallas, M.
    Pokorski, W.
    Ribon, A.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2009, 32 (3-4): : 425 - 428