Adaptation of GEANT4 to Monte Carlo dose calculations based on CT data

被引:99
|
作者
Jiang, H [1 ]
Paganetti, H
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
关键词
GEANT4; Monte Carlo; CT;
D O I
10.1118/1.1796952
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The GEANT4 Monte Carlo code provides many powerful functions for conducting particle transport simulations with great reliability and flexibility. However, as a general purpose Monte Carlo code, not all the functions were specifically designed and fully optimized for applications in radiation therapy. One of the primary issues is the computational efficiency, which is especially critical when patient CT data have to be imported into the simulation model. In this paper we summarize the relevant aspects of the GEANT4 tracking and geometry algorithms and introduce our work on using the code to conduct dose calculations based on CT data. The emphasis is focused on modifications of the GEANT4 source code to meet the requirements for fast dose calculations. The major features include a quick voxel search algorithm, fast volume optimization, and the dynamic assignment of material density. These features are ready to be used for tracking the primary types of particles employed in radiation therapy such as photons, electrons, and heavy charged particles. Recalculation of a proton therapy treatment plan generated by a commercial treatment planning program for a paranasal sinus case is presented as an example. (C) 2004 American Association of Physicists in Medicine.
引用
下载
收藏
页码:2811 / 2818
页数:8
相关论文
共 50 条
  • [1] Dynamic Monte Carlo Dose Calculations for IMRT in Geant4
    Hancox, C.
    Seco, J.
    Sharp, G.
    Peroni, M.
    Paganetti, H.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [2] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895
  • [3] Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields
    Gholami, Somayeh
    Longo, Francesco
    Nedaie, Hassan Ali
    Berti, Alessio
    Mousavi, Mehdi
    Meigooni, Ali S.
    MEDICAL DOSIMETRY, 2018, 43 (03) : 214 - 223
  • [4] Geant4 Based Monte Carlo Dose Calculation Engine for Radiation Therapy
    Xiao, Shanjie
    Yang, Xue
    Sztejnberg, Manuel
    Jevremovic, Tatjana
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (02) : 775 - 781
  • [5] GMC: a GPU implementation of a Monte Carlo dose calculation based on Geant4
    Jahnke, Lennart
    Fleckenstein, Jens
    Wenz, Frederik
    Hesser, Juergen
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05): : 1217 - 1229
  • [6] The Geant4 Virtual Monte Carlo
    Hrivnacova, I.
    INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS 2012 (CHEP2012), PTS 1-6, 2012, 396
  • [7] Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4
    Ahmad, Syed Bilal
    Sarfehnia, Arman
    Paudel, Moti Raj
    Kim, Anthony
    Hissoiny, Sami
    Sahgal, Arjun
    Keller, Brian
    MEDICAL PHYSICS, 2016, 43 (02) : 894 - 907
  • [8] Geant4 Benchmarking for IMRT Dose Calculations
    Hancox, C.
    Seco, J.
    Paganetti, H.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [9] Geant4 portlet: Monte-Carlo simulation with Geant4 on bwGRiD over a browser-based interface
    Zyl, A.
    Hesser, J.
    Mosch, C.
    Alnewaini, Z.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 168 - 169
  • [10] Analytical and Monte-Carlo (GEANT4) calculations of collimator scatter of proton beams
    Ulmer, W.
    Schaffner, B.