Risk for Flexor Pollicis Longus Rupture after Volar Lock Plating for Distal Radius Fracture Lasts Over a Decade

被引:0
|
作者
H.Nordback, Panu [1 ,2 ,3 ]
Lee, Ellen Y. [1 ]
Lim, Jin Xi [1 ]
Lim, Aymeric Y. T. [1 ]
Das De, Soumen [1 ]
机构
[1] Natl Univ Singapore Hosp, Dept Hand & Reconstruct Microsurg, Singapore, Singapore
[2] Helsinki Univ Cent Hosp, Bridge Hosp, Dept Hand Surg, Helsinki, Finland
[3] Univ Helsinki, Helsinki, Finland
来源
关键词
Distal radius fracture; Flexor pollicis longus; AFlexor tendon rupture; Tendon reconstruction; Volar locking plate fixation; FIXATION; REMOVAL;
D O I
10.22038/ABJS.2024.77674.3587
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Volar locking plate (VLP) fixation is a very common procedure due to the high incidence of distal radius fractures (DRFs). Attritional flexor tendon rupture is a rare, but recognized complication after VLP fixation. There is no current consensus to prevent the condition. Our objective was to highlight the long-term risk for flexor tendon rupture after VLP fixation. Methods: We conducted a retrospective single-center review of patients with attritional flexor tendon rupture after VLP fixation for DRFs between 2016 and 2021. Patient demographics, DRF details including AO fracture classification, Soong grading and tendon reconstruction were collected. Thumb interphalangeal joint (IPJ) motion and Kapandji score were used as outcome measures forAthe tendon reconstruction. Results: We identified five patients with attritional flexor pollicis longus (FPL) ruptures. The median age of the patients at the time of DRF was 48 (34-56) years. All VLP fixations were Soong grade 2. Median time from VLP fixation to tendon rupture was 7 (3-14) years. Longest surgery-to-rupture interval was 14 years. One rupture was treated conservatively. Four were reconstructed using palmaris longus (PL) tendon graft. Thumb IPJ active range of motion median was 48 (20-55) degrees and Kapandji score 9/10 (7-9/10). Conclusion: Older generation VLP fixations with Soong grade 2 pose a long-term risk for attritional FPL rupture, which can be reconstructed with PL tendon graft with fair to good outcomes.
引用
收藏
页码:835 / 839
页数:5
相关论文
共 50 条
  • [21] Late rupture of Flexor Pollicis Longus tendon 10 years after volar buttress plate fixation of a distal radius fracture : A case report
    Monda, Maureen K.
    Ellis, Allun
    Karmani, Shuaib
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (04): : 549 - 551
  • [22] Flexor pollicis longus tendon rupture after volar wrist plating : reconstruction with palmaris longus interposition graft
    Berger, Pieter
    Duerinckx, Joris
    ACTA ORTHOPAEDICA BELGICA, 2017, 83 (03): : 467 - 472
  • [23] Reducing the risk of flexor pollicis longus tendon rupture after volar plate fixation for distal radius fractures: validation of the tendon irritation test
    Suganuma S.
    Tada K.
    Tsuchiya H.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (8) : 1425 - 1429
  • [24] Trigger thumb preceding flexor pollicis longus tendon rupture after distal radius volar plate fixation: A case report
    Dbeis, Ammer
    Ngo, John
    Chiang, Emerald
    Ishak, Andre
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2022, 94
  • [25] Distal Radius Volar Locking Plate Design and Associated Vulnerability of the Flexor Pollicis Longus
    Limthongthang, Roongsak
    Bachoura, Abdo
    Jacoby, Sidney M.
    Osterman, A. Lee
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (05): : 852 - 860
  • [26] Ultrasonographic evaluation of contact configuration between flexor pollicis longus tendon and the volar prominence of volar plate in patients with distal radius fracture
    Kim, Jae Kwang
    Shin, Young Ho
    Kim, Minsoo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (02) : 1103 - 1108
  • [27] Ultrasonographic evaluation of contact configuration between flexor pollicis longus tendon and the volar prominence of volar plate in patients with distal radius fracture
    Jae Kwang Kim
    Young Ho Shin
    Minsoo Kim
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 1103 - 1108
  • [28] The Effect of Plate Design on the Flexor Pollicis Longus Tendon After Volar Locked Plating of Distal Radial Fractures
    Stepan, Jeffrey G.
    Marshall, Danielle C.
    Wessel, Lauren E.
    Endo, Yoshimi
    Miller, Theodore T.
    Sacks, Hayley A.
    Weiland, Andrew J.
    Fufa, Duretti T.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (17): : 1586 - 1592
  • [29] Delayed Extensor Pollicis Longus Rupture after Distal Radius Fracture in a Pediatric Patient
    Munaretto, Nicholas
    Clark, Nicholas J.
    Kakar, Sanjeev
    JOURNAL OF HAND AND MICROSURGERY, 2023, 15 (03) : 240 - 241
  • [30] Evaluation of flexor pollicis longus tendon attrition using color Doppler imaging after volar plate fixation for distal radius fracture
    Tanaka, Yoshitaka
    Gotani, Hiroyuki
    Yano, Koichi
    Sasaki, Kosuke
    Hamada, Yoshitaka
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2017, 22 (03) : 447 - 452