Advancements in heavy metal detection using microneedle array technology

被引:1
|
作者
Taylor, Robert M. [1 ]
Ali, Abdul-Mehdi S. [2 ]
Zhu, Yiliang [3 ]
Bolt, Alicia M. [4 ]
Baca, Justin T. [1 ]
机构
[1] Univ New Mexico, Dept Emergency Med, Albuquerque, NM 87106 USA
[2] Univ New Mexico, Dept Earth & Planetary Sci, Albuquerque, NM USA
[3] Univ New Mexico, Dept Internal Med, Albuquerque, NM USA
[4] Univ New Mexico, Coll Pharm, Dept Pharmaceut Sci, Albuquerque, NM 87106 USA
基金
美国国家卫生研究院;
关键词
Microneedle; interstitial fluid; ISF; heavy metals; inductively coupled plasma-mass spectrometry; ICP-MS; INTERSTITIAL FLUID; EXTRACTION;
D O I
10.1080/15376516.2025.2461647
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Heavy metal and metalloid (HM) exposure poses significant health risks, including cardiovascular disease, cancer, and renal damage. This contamination, prevalent in the Western US, involves arsenic (As), cadmium (Cd), uranium (U), and vanadium (V). Interstitial fluid (ISF) is a source of biomarkers, which can be minimally invasively collected using microneedle array (MA) technology. Our study hypothesized that MA-extracted ISF would facilitate noninvasive HM quantification. We established analytical parameters for HM detection in ISF using inductively coupled plasma-mass spectrometry (ICP-MS), defined baseline ISF HM concentrations in unexposed animal populations, and monitored HM levels in ISF under mixed exposure in animal models. Additionally, we assessed HM levels in ISF and biological fluids from three human subjects. Thirty-six Sprague-Dawley rats were divided into cohorts: low-level mixed HMs exposure (5X maximum contaminant level (MCL)); high-level single HM with low-level others (50X MCL for one HM with 5X for others); and unexposed controls. ISF and plasma were collected weekly for 8 weeks and analyzed via ICP-MS. Our findings reveal a correlation between ISF and plasma HM levels, underscoring ISF's potential for real-time monitoring of HM exposure. This study also establishes baseline ISF HM levels, illustrating the feasibility of HM quantification using small ISF volumes.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Phytoexclusion of heavy metals using low heavy metal accumulating cultivars: A green technology
    Wang, Liang
    Zhang, Qingying
    Liao, Xiaoyong
    Li, Xiaohua
    Zheng, Shunan
    Zhao, Fenghua
    JOURNAL OF HAZARDOUS MATERIALS, 2021, 413
  • [42] Latest advancements towards delamination detection in a FCOB assembly using Thermal Pixel (Thixel) array
    Kumar, Akhil
    Schulz, Marcus
    Bader, Volker
    Wahrmann, Markus
    Bauer, Joerg
    May, Daniel
    Puri, Aakash
    Ras, Mohamad Abo
    Wunderle, Bernhard
    2019 25TH INTERNATIONAL WORKSHOP ON THERMAL INVESTIGATIONS OF ICS AND SYSTEMS (THERMINIC 2019), 2019,
  • [43] THE PHOTOELECTRIC AEROSOL SENSOR ARRAY AS INSTRUMENT FOR THE ONLINE DETECTION OF HEAVY-METAL AEROSOLS
    NIESSNER, R
    HEMMERICH, B
    PANNE, U
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 333 (07): : 704 - 705
  • [44] Fabrication of microneedle array using LIGA and hot embossing process
    Sang Jun Moon
    Seung S. Lee
    H. S. Lee
    T. H. Kwon
    Microsystem Technologies, 2005, 11 : 311 - 318
  • [45] Fabrication of microneedle array using LIGA and hot embossing process
    Moon, SJ
    Lee, SS
    Lee, HS
    Kwon, TH
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2005, 11 (4-5): : 311 - 318
  • [46] Dissolvable microneedle fabrication using piezoelectric dispensing technology
    Allen, Evin A.
    O'Mahony, Conor
    Cronin, Michael
    O'Mahony, Thomas
    Moore, Anne C.
    Crean, Abina M.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2016, 500 (1-2) : 1 - 10
  • [47] A study on the fabrication of metal microneedle array electrodes for ECG detection based on low melting point Bi-In-Sn alloys
    Gwak, Hyunjong
    Cho, Sungbo
    Song, Yoon-Jae
    Park, Jung-Hwan
    Seo, Soonmin
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [48] Machine learning enabled onsite electrochemical detection of lidocaine using a microneedle array integrated screen printed electrode
    Kadian, Sachin
    Sahoo, Siba Sundar
    Kumari, Pratima
    Narayan, Roger J.
    ELECTROCHIMICA ACTA, 2024, 475
  • [49] Minimally invasive detection of buprenorphine using a carbon-coated 3D-printed microneedle array
    Kadian, Sachin
    Sahoo, Siba Sundar
    Kumari, Pratima
    Shukla, Shubhangi
    Narayan, Roger J.
    MICROCHIMICA ACTA, 2024, 191 (11)
  • [50] Heavy metal contamination detection using x-rays
    Aljundi, T
    Jensen, T
    Gray, JN
    Robinson, D
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 15A AND 15B, 1996, 15 : 465 - 472