Accuracy of an autonomous dental implant robotic system in dental implant surgery

被引:1
|
作者
Wu, Yu [1 ]
Zou, Shiqi [1 ]
Lv, Pin [1 ]
Wang, Xiao [1 ]
机构
[1] Peking Univ, Dept Stomatol, Hosp 3, 49 North Garden Rd, Beijing 100191, Peoples R China
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2025年 / 133卷 / 03期
关键词
PLACEMENT; FAILURES;
D O I
10.1016/j.prosdent.2024.07.020
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Autonomous dental implant robot systems (ADIRSs) have been marketed for dental implant surgery; however, research on their accuracy is limited. Purpose. The purpose of this clinical study was to examine the accuracy of an ADIRS. Material and methods. Seventy-four participants with partial edentulism underwent implant surgery by using the ADIRS. Before surgery, a cone beam computed tomography (CBCT) scan was conducted, and its image data were fed into the ADIRS navigation and positioning system for iterative reconstruction and surgical path planning. After local anesthesia administration, area disinfection, and patient registration, the robot prepared the osteotomy and placed the implant under guidance of the navigation system. A postoperative CBCT scan was made to assess deviations between the planned and actual implant positions. The global coronal, apical, and angular deviations were measured and analyzed. A generalized linear mixed model (GLMM) was used to compare the differences in major outcome variables (alpha=.05). Results. All implant procedures were successfully carried out without any complications during surgery. A total of 86 implants were placed in 74 participants. The mean +/- standard deviation global coronal deviation, global apical deviation, and angular deviation was 0.61 +/- 0.20 mm (95% CI: 0.23 to 1.0 mm), 0.79 +/- 0.32 mm (95% CI: 0.17 to 1.41 mm), and 2.56 +/- 1.10 degrees (95% CI: 0.42 to 4.70 degrees), respectively. The findings from the GLMM revealed that the implant region (premolar, molar; maxilla, mandible; left, right), implant length, and surgeon did not significantly impact accuracy (P>.05). Conclusions. ADIRS showed high accuracy for implant placement because of the control of angular deviation and axial errors. The implant region, implant length, and surgeon had no significant influence on the accuracy of implant placement. Nevertheless, more clinical studies are required to support evidence-based clinical outcomes. (J Prosthet Dent 2025;133:764-770)
引用
收藏
页码:764 / 770
页数:7
相关论文
共 50 条
  • [31] A method to evaluate the accuracy of dental implant placement without postoperative radiography after computer-guided implant surgery: A dental technique
    Son, KeunBaDa
    Huang, Mei-Yang
    Lee, Kyu-Bok
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (05): : 661 - 666
  • [32] Dynamic Navigation for Dental Implant Surgery
    Panchal, Neeraj
    Mahmood, Laith
    Retana, Armando
    Emery, Robert, III
    ORAL AND MAXILLOFACIAL SURGERY CLINICS OF NORTH AMERICA, 2019, 31 (04) : 539 - +
  • [33] Assessment of Complications in Dental Implant Surgery
    Guruprasad, Yadavalli
    Ibrahim, Mohammed
    Singh, Kamlesh
    Shetty, Smitha
    Garg, Dev Kumar
    Srilakshmi, Donka
    Karre, Shivani
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2437 - S2439
  • [34] FULL LASER DENTAL IMPLANT SURGERY
    Ingenegeren, Ingmar
    LASERS IN SURGERY AND MEDICINE, 2009, : 56 - 57
  • [35] Importance of anatomy in dental implant surgery
    Kageyama, Ikuo
    Maeda, Shingo
    Takezawa, Kojiro
    JOURNAL OF ORAL BIOSCIENCES, 2021, 63 (02) : 142 - 152
  • [36] The influence of dental experience on a dental implant navigation system
    Ting-Mao Sun
    Huey-Er Lee
    Ting-Hsun Lan
    BMC Oral Health, 19
  • [37] The accuracy of a novel image-guided hybrid robotic system for dental implant placement: An in vitro study
    Tao, Baoxin
    Feng, Yuan
    Fan, Xingqi
    Lan, Kengliang
    Zhuang, Minjie
    Wang, Shigang
    Wang, Feng
    Chen, Xiaojun
    Wu, Yiqun
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2023, 19 (01):
  • [38] The influence of dental experience on a dental implant navigation system
    Sun, Ting-Mao
    Lee, Huey-Er
    Lan, Ting-Hsun
    BMC ORAL HEALTH, 2019, 19 (01)
  • [39] DENTAL IMPLANT
    SODER, PO
    SWEDISH DENTAL JOURNAL, 1986, 10 (06) : 266 - 266
  • [40] Flapless dental implant surgery enabled by haptic robotic guidance: A case report
    Ali, Mohamed
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 251 - 257