摘要
Statement of problem. Autonomous dental implant robot systems (ADIRSs) have been marketed for dental implant surgery; however, research on their accuracy is limited. Purpose. The purpose of this clinical study was to examine the accuracy of an ADIRS. Material and methods. Seventy-four participants with partial edentulism underwent implant surgery by using the ADIRS. Before surgery, a cone beam computed tomography (CBCT) scan was conducted, and its image data were fed into the ADIRS navigation and positioning system for iterative reconstruction and surgical path planning. After local anesthesia administration, area disinfection, and patient registration, the robot prepared the osteotomy and placed the implant under guidance of the navigation system. A postoperative CBCT scan was made to assess deviations between the planned and actual implant positions. The global coronal, apical, and angular deviations were measured and analyzed. A generalized linear mixed model (GLMM) was used to compare the differences in major outcome variables (alpha=.05). Results. All implant procedures were successfully carried out without any complications during surgery. A total of 86 implants were placed in 74 participants. The mean +/- standard deviation global coronal deviation, global apical deviation, and angular deviation was 0.61 +/- 0.20 mm (95% CI: 0.23 to 1.0 mm), 0.79 +/- 0.32 mm (95% CI: 0.17 to 1.41 mm), and 2.56 +/- 1.10 degrees (95% CI: 0.42 to 4.70 degrees), respectively. The findings from the GLMM revealed that the implant region (premolar, molar; maxilla, mandible; left, right), implant length, and surgeon did not significantly impact accuracy (P>.05). Conclusions. ADIRS showed high accuracy for implant placement because of the control of angular deviation and axial errors. The implant region, implant length, and surgeon had no significant influence on the accuracy of implant placement. Nevertheless, more clinical studies are required to support evidence-based clinical outcomes. (J Prosthet Dent 2025;133:764-770)
引用
收藏
页码:764 / 770
页数:7
相关论文
共 50 条
  • [21] Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study
    Chen, Jianping
    Bai, Xiaolei
    Ding, Yude
    Shen, Liheng
    Sun, Xin
    Cao, Ruijue
    Yang, Fan
    Wang, Linhong
    BMC ORAL HEALTH, 2023, 23 (01)
  • [22] Accuracy of dental implant surgery with robotic position feedback and registration algorithm: An in-vitro study
    Cheng, Kang-jie
    Kan, Tian-shu
    Liu, Yun-feng
    Zhu, Wei-dong
    Zhu, Fu-dong
    Wang, Wei-bin
    Jiang, Xian-feng
    Dong, Xing-tao
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 129
  • [24] DENTAL AND CRANIOMAXILLOFACIAL IMPLANT SURGERY
    Smith, Richard A.
    Block, Michael S.
    Sclar, Anthony G.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (11) : E72 - E106
  • [25] DENTAL AND CRANIOMAXILLOFACIAL IMPLANT SURGERY
    Triplett, R. Gilbert
    Berger, Joel
    Jensen, Ole
    Louis, Patrick
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (08) : E74 - E93
  • [26] Implant placement with an autonomous dental implant robot: A clinical report
    Li, Zhiwen
    Xie, Rui
    Bai, Shizhu
    Zhao, Yimin
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (02): : 340 - 345
  • [27] Dental implant navigation system guide the surgery future
    Sun, Ting-Mao
    Lan, Ting-Hsun
    Pan, Chin-Yun
    Lee, Huey-Er
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2018, 34 (01): : 56 - 64
  • [28] Accuracy and efficiency of robotic dental implant surgery with different human-robot interactions: An in vitro study
    Xu, Zonghe
    Xiao, Yanjun
    Zhou, Lin
    Lin, Yanjun
    Su, Endian
    Chen, Jiang
    Wu, Dong
    JOURNAL OF DENTISTRY, 2023, 137
  • [29] Accuracy of a Dynamic Dental Implant Navigation System in a Private Practice
    Stefanelli, Luigi, V
    DeGroot, Bradley S.
    Lipton, David, I
    Mandelaris, George A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (01) : 205 - 213
  • [30] Accuracy of a newly developed integrated system for dental implant planning
    Dreiseidler, Timo
    Neugebauer, Joerg
    Ritter, Lutz
    Lingohr, Thea
    Rothamel, Daniel
    Mischkowski, Robert A.
    Zoeller, Joachim E.
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (11) : 1191 - 1199