Analytical model for characterizing mass transfer of volatile organic compounds in internally-cooled liquid desiccant dehumidifiers

被引:0
|
作者
Liu, Zhihang [1 ]
Fu, Huangxi [1 ]
Huang, Shunyi [1 ]
机构
[1] Jiangxi Univ Sci & Technol, Sch Civil & Surveying & Mapping Engn, Ganzhou 341000, Peoples R China
关键词
Analytical model; Mass transfer; Volatile organic compounds; Liquid desiccant; Internally-cooled dehumidifier; INDOOR AIR-QUALITY; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2025.126109
中图分类号
O414.1 [热力学];
学科分类号
摘要
Volatile organic compounds (VOCs) in indoor air pose a significant hazard to human health, owing to their potential associated chronic and acute health risks. Liquid dehumidification has emerged as a promising technology for eliminating indoor VOCs. However, the studies on the mass transfer behavior of VOCs in dehumidifiers are mainly confined to experimental and numerical methods, which are both time-consuming and labor-intensive. In contrast, analytical methods are more attractive and advantageous in solving these problems. Therefore, in the present study, we propose an analytical model to quantify the mass transfer behavior of VOCs in an internally-cooled dehumidifier. To confirm the broad applicability of the proposed model, both the hydrophilic and hydrophobic properties of VOCs were considered. Formaldehyde and benzene were selected as two typical representatives. The reliability of the proposed model was demonstrated by investigating the VOC transfer characteristics and removal performance as the key factors varied. It was found that the analytical results agree well with the published numerical results. With variation of the key parameters, the trends of the VOC removal performance obtained by the analytical and numerical methods are basically in agreement. The analytical model can not only effectively describe the mass transfer characteristics of VOCs, but also adequately determine the VOCs removal performance. Moreover, the analytical model shows a wide-range response to different VOCs, with the order of Henry's law constant ranging from 10-5 to 10-3. For both hydrophilic formaldehyde and hydrophobic benzene, the deviations do not exceed +/- 10 %. This study provides an intuitive and labor-saving method to evaluate VOC removal using internally-cooled dehumidifiers.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] A Theoretical Model on Internally Cooled Liquid Desiccant Dehumidification and Cooling Processes
    Alan, S. W. L.
    Islam, M. R.
    Chua, K. J.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 1009 - 1014
  • [42] A review of heat and mass transfer mechanisms of dehumidifiers and regenerators for liquid desiccant cooling systems
    Ren, Haoshan
    Sun, Yongjun
    Lin, Wenye
    Wang, Shugang
    Li, Weihua
    Ma, Zhenjun
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 26 (04) : 465 - 483
  • [43] Determination of cost-efficient cooling power range for improving the performance of internally cooled ultrasonic atomization liquid desiccant dehumidifiers
    Yang, Zili
    Chen, Lu-An
    Tao, Ruiyang
    Zhong, Ke
    INDOOR AND BUILT ENVIRONMENT, 2020, 29 (09) : 1260 - 1276
  • [44] High-performance multi-stage internally-cooled liquid desiccant dehumidifier for high gas-liquid flow ratios
    Fang, Song
    Xu, Zhuoren
    Zhang, Hanwei
    Rong, Yangyiming
    Zhou, Xia
    Zhi, Xiaoqin
    Wang, Kai
    Markides, Christos N.
    Qiu, Limin
    ENERGY CONVERSION AND MANAGEMENT, 2021, 250
  • [45] Investigation on Performance of Internally Cooled Liquid Desiccant Dehumidifier Based on ANN Model
    Luo, Yimo
    Chang, Yayin
    Li, Nianping
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2024, 51 (09): : 198 - 205
  • [46] Experimental and 4 NTU-Le heat and mass transfer model theoretical analysis based on a novel internally cooled liquid desiccant dehumidifier
    Zhang, Guangkai
    Tan, Jingjie
    Xie, Jingchao
    Du, Boyao
    Liu, Honggang
    Liu, Jiaping
    ENERGY, 2024, 313
  • [47] A review of heat and mass transfer improvement techniques for dehumidifiers and regenerators of liquid desiccant cooling systems
    Ren, Haoshan
    Ma, Zhenjun
    Liu, Jingjing
    Gong, Xuemei
    Li, Weihua
    APPLIED THERMAL ENGINEERING, 2019, 162
  • [48] Development of simplified prediction model for internally cooled/heated liquid desiccant dehumidification system
    Qi, Ronghui
    Lu, Lin
    Yang, Hongxing
    ENERGY AND BUILDINGS, 2013, 59 : 133 - 142
  • [49] Advances in heat and mass transfer in the membrane-based dehumidifiers and liquid desiccant air dehumidification systems
    Huang, Si-Min
    Yuan, Wu-Zhi
    Yang, Minlin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 139 : 881 - 906
  • [50] Optimal flow type in internally-cooled liquid-desiccant system driven by heat pump: Component level vs. System level
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    Liu, Jun
    APPLIED THERMAL ENGINEERING, 2021, 183 (183)