A Bicortical Pedicle Screw in the Cephalad Trajectory Is the Best Option for the Fixation of an Osteoporotic Vertebra: A Finite Element Study

被引:0
|
作者
Murata, Akimasa [1 ]
Tsutsui, Shunji [1 ]
Yamamoto, Ei [2 ]
Kozaki, Takuhei [1 ]
Nakanishi, Ryuichiro [1 ]
Yamada, Hiroshi [1 ]
机构
[1] Wakayama Med Univ, Dept Orthopaed Surg, Wakayama, Japan
[2] Kindai Univ, Fac Biol Oriented Sci & Technol, Dept Biomed Engn, Kinokawa, Japan
来源
SPINE SURGERY AND RELATED RESEARCH | 2024年 / 8卷 / 05期
关键词
osteoporosis; pedicle screw; depth; trajectory; finite element analysis; LUMBAR SPINE FUSION; STRENGTH; COMPLICATIONS; INSERTION; DEVICE; LOADS;
D O I
10.22603/ssrr.2023-0249
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Pedicle screws are commonly used in fixation to treat various spinal disorders. However, screw loosening is a prevalent complication, particularly in patients with osteoporosis. Various biomechanical studies have sought to address this issue, but the optimal depth and trajectory to increase the fixation strength of pedicle screws remain controversial. Therefore, a biomechanical study was conducted using finite element models. Methods: Three-dimensional finite element models of the L3 vertebrae were developed from the preoperative computed tomography images of nine patients with osteoporosis and nine patients without who underwent spine surgery. Unicortical and bicortical pedicle screws were inserted into the center and into the anterior wall of the vertebrae, respectively, in different trajectories in the sagittal plane: straightforward, cephalad, and caudal. Subsequently, three different external loads were applied to each pedicle screw at the entry point: axial pullout, craniocaudal, and lateromedial loads. Nonlinear analysis was conducted to examine the fixation strength of the pedicle screws. Results: Irrespective of osteoporosis, the bicortical pedicle screws had greater fixation strength than the unicortical pedicle screws in all trajectories and external loads. The fixation strength of the bicortical pedicle screws was not substantially different among the trajectories against any external loads in the nonosteoporotic vertebrae. However, the fixation strength of the bicortical pedicle screws against craniocaudal load in the cephalad trajectory was considerably greater than those in the caudal (P=0.016) and straightforward (P=0.023) trajectories in the osteoporotic vertebrae. However, this trend was not Conclusions: Our results indicate that bicortical pedicle screws should be used, regardless of whether the patient has osteoporosis or not. Furthermore, pedicle screws should be inserted in the cephalad trajectory in patients with osteoporosis.
引用
收藏
页码:510 / 517
页数:8
相关论文
共 50 条
  • [11] Shape Memory Alloy Expandable Pedicle Screw to Enhance Fixation in Osteoporotic Bone: Primary Design and Finite Element Simulation
    Tabesh, Majid
    Goel, Vijay
    Elahinia, Mohammad H.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2012, 6 (03):
  • [12] Individualized prediction of pedicle screw fixation strength with a finite element model
    Widmer, Jonas
    Fasser, Marie-Rosa
    Croci, Eleonora
    Spirig, Jose
    Snedeker, Jess G.
    Farshad, Mazda
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (04) : 155 - 167
  • [13] The Biomechanical Properties of Pedicle Screw Fixation Combined With Trajectory Bone Cement Augmentation in Osteoporotic Vertebrae
    Fan, Haitao T.
    Zhang, Renjie J.
    Shen, Cailiang L.
    Dong, Fulong L.
    Li, Yong
    Song, Peiwen W.
    Gong, Chen
    Wang, Yijin J.
    CLINICAL SPINE SURGERY, 2016, 29 (02): : 78 - 85
  • [14] Comparison of Pedicle Screw Fixation Strength Among Different Transpedicular Trajectories A Finite Element Study
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Hynes, Richard A.
    Imabayashi, Hideaki
    Hosogane, Naobumi
    Yoshihara, Yasuo
    Asazuma, Takashi
    Nemoto, Koichi
    CLINICAL SPINE SURGERY, 2017, 30 (07): : 301 - 307
  • [15] S2-alar-iliac screw and S1 pedicle screw fixation for the treatment of non-osteoporotic sacral fractures: a finite element study
    Jianxiong Zheng
    Xiaoreng Feng
    Jie Xiang
    Fei Liu
    Frankie K. L. Leung
    Bin Chen
    Journal of Orthopaedic Surgery and Research, 16
  • [16] S2-alar-iliac screw and S1 pedicle screw fixation for the treatment of non-osteoporotic sacral fractures: a finite element study
    Zheng, Jianxiong
    Feng, Xiaoreng
    Xiang, Jie
    Liu, Fei
    Leung, Frankie K. L.
    Chen, Bin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [17] Axis screw parallel to the sagittal plane versus traditional pedicle screw in the treatment of atlantoaxial fixation: a finite element study
    Zeng, Baifang
    Ding, Meng
    Li, Lang
    Wu, Chao
    Qin, Bingwei
    Shen, Danwei
    Deng, Jiayan
    Wang, Xiangyu
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [18] Investigation of optical reflectance from different animal vertebra along the fixation trajectory of pedicle screw in frequency domain
    Liu, Yangyang
    Zhang, Huan
    Tong, Ying
    Qian, Zhiyu
    Li, Weitao
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2020, 13 (01)
  • [19] A novel calcium phosphate cement used for enhanced pedicle screw fixation: A biomechanical study with finite element
    Chao-Dong Deng
    Zhi-Qiang Gong
    Shao-Li Wang
    Wei Song
    Yi-Lin Zhang
    Ting-Ting Yan
    Journal of Materials Research, 2022, 37 : 3535 - 3546
  • [20] A novel calcium phosphate cement used for enhanced pedicle screw fixation: A biomechanical study with finite element
    Deng, Chao-Dong
    Gong, Zhi-Qiang
    Wang, Shao-Li
    Song, Wei
    Zhang, Yi-Lin
    Yan, Ting-Ting
    JOURNAL OF MATERIALS RESEARCH, 2022, 37 (21) : 3535 - 3546