Comparison of Pedicle Screw Fixation Strength Among Different Transpedicular Trajectories A Finite Element Study

被引:39
|
作者
Matsukawa, Keitaro [1 ]
Yato, Yoshiyuki [2 ]
Hynes, Richard A. [3 ]
Imabayashi, Hideaki [1 ]
Hosogane, Naobumi [1 ]
Yoshihara, Yasuo [1 ]
Asazuma, Takashi [2 ]
Nemoto, Koichi [1 ]
机构
[1] Natl Def Med Coll, Dept Orthopaed Surg, 3-2 Namiki, Tokorozawa, Saitama 3598513, Japan
[2] Natl Hosp Org, Murayama Med Ctr, Dept Orthopaed Surg, Tokyo, Japan
[3] Florida Inst Technol, Dept Engn, Melbourne, FL 32901 USA
来源
CLINICAL SPINE SURGERY | 2017年 / 30卷 / 07期
关键词
cortical bone trajectory; finite element method; lumbar pedicle screw; insertional trajectory; bone mineral density; screw stability; transpedicular; BONE-MINERAL DENSITY; LUMBAR PEDICLE; IN-VITRO; INSERTION; BIOMECHANICS; FATIGUE;
D O I
10.1097/BSD.0000000000000258
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: Comparative biomechanical study by finite element (FE) method. Objective: To investigate the pullout strength of pedicle screws using different insertional trajectories. Summary of Background Data: Pedicle screw fixation has become the gold standard for spinal fusion, however, not much has been done to clarify how the fixation strength of pedicle screws are affected by insertional trajectories and bone properties. Materials and Methods: Three-dimensional FE models of 20 L4 vertebrae were constructed from the computed tomographic data. Five different transpedicular trajectories were compared: the traditional trajectory, the vertical trajectory, and the 3 lateral trajectories with different sagittal directions (caudal, parallel, cranial). For a valid comparison, screws of the same shape and size were inserted into the same pedicle in each subject, and the pullout strength were compared with nonlinear FE analyses. In addition, the pullout strength was correlated with bone mineral density (BMD). Results: The mean pullout strength showed a 3.9% increase for the vertical trajectory relative to the traditional trajectory, 6.1% for the lateral-caudal trajectory, 21.1% for the lateral-parallel trajectory, and 34.7% for the lateral-cranial trajectory. The lateral-cranial trajectory demonstrated the highest value among all trajectories (P< 0.001). In each trajectory, the correlation coefficient between the pullout strength and BMD of the femoral neck (r= 0.74-0.83, P< 0.01) was higher than the mean BMD of all the lumbar vertebrae (r= 0.49-0.75, P< 0.01), BMD of the L4 vertebra (r= 0.39-0.64, P< 0.01), and regional BMD of the L4 pedicle (r= 0.53-0.76, P< 0.01). Conclusions: Regional variation in the vertebral bone density and the amount of denser bone-screw interface contribute to the differences of stiffness among different screw trajectories. BMD of the femoral neck is considered to be a better objective predictor of pedicle screw stability than that of the lumbar vertebra.
引用
收藏
页码:301 / 307
页数:7
相关论文
共 50 条
  • [1] Individualized prediction of pedicle screw fixation strength - an experimentally validated finite element study
    Widmer, Jonas
    Fasser, Marie-Rosa
    Croci, Eleonora
    Spirig, Jose
    Snedeker, Jess
    Farshad, Mazda
    SWISS MEDICAL WEEKLY, 2019, 149 : 26S - 26S
  • [2] Individualized prediction of pedicle screw fixation strength with a finite element model
    Widmer, Jonas
    Fasser, Marie-Rosa
    Croci, Eleonora
    Spirig, Jose
    Snedeker, Jess G.
    Farshad, Mazda
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (04) : 155 - 167
  • [3] Impact of Screw Diameter and Length on Pedicle Screw Fixation Strength in Osteoporotic Vertebrae: A Finite Element Analysis
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Imabayashi, Hideaki
    ASIAN SPINE JOURNAL, 2021, 15 (05) : 566 - 574
  • [4] Biomechanical comparison of pedicle screw fixation strength among three different screw trajectories using single vertebrae and one-level functional spinal unit
    Tai, Ching-Lung
    Chen, Weng-Pin
    Liu, Mu-Yi
    Li, Yun-Da
    Tsai, Tsung-Ting
    Lai, Po-Liang
    Hsieh, Ming-Kai
    Frontiers in Bioengineering and Biotechnology, 2022, 10
  • [5] Biomechanical comparison of pedicle screw fixation strength among three different screw trajectories using single vertebrae and one-level functional spinal unit
    Tai, Ching-Lung
    Chen, Weng-Pin
    Liu, Mu-Yi
    Li, Yun-Da
    Tsai, Tsung-Ting
    Lai, Po-Liang
    Hsieh, Ming-Kai
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [6] DETERMINATION OF TRANSPEDICULAR SCREW PARAMETERS WITH THE HELP OF PEDICLE MORPHOMETRY OF THORACIC VERTEBRAE FOR SAFE TRANSPEDICULAR SCREW FIXATION - A CADAVERIC STUDY
    Gangadhara
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2013, 2 (36): : 6807 - 6815
  • [7] Pullout strength of thoracic pedicle screw instrumentation - Comparison of the transpedicular and extrapedicular techniques
    White, Klane K.
    Oka, Richard
    Mahar, Andrew T.
    Lowry, Alexandra
    Garfin, Steven R.
    SPINE, 2006, 31 (12) : E355 - E358
  • [8] Biomechanical analysis of interbody and posterolateral fusion with transpedicular screw fixation for spondylolisthesis: A finite element study
    Liu, Heng-Liang
    Sun, Ming-Tsung
    Lin, Chun-Li
    Cheng, Hsin-Yi
    Wei, Kou-Chen
    Su, Wen-Kai
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2008, 20 (03): : 145 - 151
  • [9] Biomechanical Evaluation of the Transcortical and Transpedicular Trajectories for Pedicle Screw Insertion in Thoracolumbar Fracture Fixation for Ankylosing Spondylitis
    Tong, Zhizhong
    Xiao, Bin
    Yan, Kai
    Xing, Yonggang
    Zhang, Yanbin
    FRONTIERS IN SURGERY, 2021, 8
  • [10] EVALUATION AND ANALYSIS OF STRAIN IN THE SCREW HEAD FOR LUMBAR PEDICLE SCREW FIXATION: AN EXPERIMENTAL AND FINITE ELEMENT STUDY
    Rana, Masud
    Majumdar, Sourav
    Jain, Pushpdant
    Malas, Anindya
    Pradhan, Rururaja
    Choudhury, Sandeep
    Biswas, Jayanta Kumar
    INTERNATIONAL JOURNAL FOR MULTISCALE COMPUTATIONAL ENGINEERING, 2021, 19 (02) : 21 - 28