Comparison of Pedicle Screw Fixation Strength Among Different Transpedicular Trajectories A Finite Element Study

被引:39
|
作者
Matsukawa, Keitaro [1 ]
Yato, Yoshiyuki [2 ]
Hynes, Richard A. [3 ]
Imabayashi, Hideaki [1 ]
Hosogane, Naobumi [1 ]
Yoshihara, Yasuo [1 ]
Asazuma, Takashi [2 ]
Nemoto, Koichi [1 ]
机构
[1] Natl Def Med Coll, Dept Orthopaed Surg, 3-2 Namiki, Tokorozawa, Saitama 3598513, Japan
[2] Natl Hosp Org, Murayama Med Ctr, Dept Orthopaed Surg, Tokyo, Japan
[3] Florida Inst Technol, Dept Engn, Melbourne, FL 32901 USA
来源
CLINICAL SPINE SURGERY | 2017年 / 30卷 / 07期
关键词
cortical bone trajectory; finite element method; lumbar pedicle screw; insertional trajectory; bone mineral density; screw stability; transpedicular; BONE-MINERAL DENSITY; LUMBAR PEDICLE; IN-VITRO; INSERTION; BIOMECHANICS; FATIGUE;
D O I
10.1097/BSD.0000000000000258
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: Comparative biomechanical study by finite element (FE) method. Objective: To investigate the pullout strength of pedicle screws using different insertional trajectories. Summary of Background Data: Pedicle screw fixation has become the gold standard for spinal fusion, however, not much has been done to clarify how the fixation strength of pedicle screws are affected by insertional trajectories and bone properties. Materials and Methods: Three-dimensional FE models of 20 L4 vertebrae were constructed from the computed tomographic data. Five different transpedicular trajectories were compared: the traditional trajectory, the vertical trajectory, and the 3 lateral trajectories with different sagittal directions (caudal, parallel, cranial). For a valid comparison, screws of the same shape and size were inserted into the same pedicle in each subject, and the pullout strength were compared with nonlinear FE analyses. In addition, the pullout strength was correlated with bone mineral density (BMD). Results: The mean pullout strength showed a 3.9% increase for the vertical trajectory relative to the traditional trajectory, 6.1% for the lateral-caudal trajectory, 21.1% for the lateral-parallel trajectory, and 34.7% for the lateral-cranial trajectory. The lateral-cranial trajectory demonstrated the highest value among all trajectories (P< 0.001). In each trajectory, the correlation coefficient between the pullout strength and BMD of the femoral neck (r= 0.74-0.83, P< 0.01) was higher than the mean BMD of all the lumbar vertebrae (r= 0.49-0.75, P< 0.01), BMD of the L4 vertebra (r= 0.39-0.64, P< 0.01), and regional BMD of the L4 pedicle (r= 0.53-0.76, P< 0.01). Conclusions: Regional variation in the vertebral bone density and the amount of denser bone-screw interface contribute to the differences of stiffness among different screw trajectories. BMD of the femoral neck is considered to be a better objective predictor of pedicle screw stability than that of the lumbar vertebra.
引用
收藏
页码:301 / 307
页数:7
相关论文
共 50 条
  • [11] EVALUATION AND ANALYSIS OF STRAIN IN THE SCREW HEAD FOR LUMBAR PEDICLE SCREW FIXATION: AN EXPERIMENTAL AND FINITE ELEMENT STUDY
    Rana M.
    Majumdar S.
    Jain P.
    Malas A.
    Pradhan R.
    Choudhury S.
    Biswas J.K.
    International Journal for Multiscale Computational Engineering, 2021, 19 (02): : 21 - 28
  • [12] Measurement of strain in the rod for lumbar pedicle screw fixation: An experimental and finite element study
    Rana, Masud
    Biswas, Jayanta Kumar
    Roy, Sandipan
    Ghosh, Niloy
    Bhattacharya, Shambo
    Karmakar, Santanu Kumar
    Roychowdhury, Amit
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (06)
  • [13] Comparison of Pedicle Screw Loosening Mechanisms and the Effect on Fixation Strength
    Mehmanparast, Hedayeh
    Petit, Yvan
    Mac-Thiong, Jean-Marc
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (12):
  • [14] Screw Pullout Strength After Pedicle Screw Reposition: A Finite Element Analysis
    Ye, Yu-Xing
    Huang, Da-Geng
    Hao, Ding-Jun
    Liu, Jia-Yuan
    Ji, Jia-Jia
    Guo, Jin-Niu
    SPINE, 2023, 48 (22) : E382 - E388
  • [15] Anterior cervical transpedicular screw fixation system in subaxial cervical spine: A finite element comparative study
    Li, Jie
    Gan, Kaifeng
    Chen, Binhui
    Chen, Yilei
    Hong, Jinjiong
    Bei, Dikai
    Fan, Tengdi
    Zheng, Minzhe
    Zhao, Liujun
    Zhao, Fengdong
    MEDICINE, 2022, 101 (29) : E29316
  • [16] Effects of the Insertion Type and Depth on the Pedicle Screw Pullout Strength: A Finite Element Study
    Jendoubi, K.
    Khadri, Y.
    Bendjaballah, M.
    Slimane, N.
    APPLIED BIONICS AND BIOMECHANICS, 2018, 2018
  • [17] Biomechanical comparison of pedicle screw fixation strength between traditional trajectory and the single and double endplates penetrating screw trajectories in cadaver spine
    Takeuchi, Takumi
    Takamizawa, Yuhei
    Jinnai, Kaito
    Kawano, Yosuke
    Moroi, Takehiko
    Konishi, Kazumasa
    Takahashi, Masahito
    Nagase, Miki
    Hosogane, Naobumi
    EUROPEAN SPINE JOURNAL, 2025,
  • [18] Effect of two-level pedicle-screw fixation with different rod materials on lumbar spine: A finite element study
    Biswas, Jayanta Kumar
    Rana, Masud
    Majumder, Santanu
    Karmakar, Santanu Kumar
    Roychowdhury, Amit
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (02) : 258 - 265
  • [19] Axis screw parallel to the sagittal plane versus traditional pedicle screw in the treatment of atlantoaxial fixation: a finite element study
    Zeng, Baifang
    Ding, Meng
    Li, Lang
    Wu, Chao
    Qin, Bingwei
    Shen, Danwei
    Deng, Jiayan
    Wang, Xiangyu
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [20] Biomechanical Comparison of Corticopedicular Spine Fixation versus Pedicle Screw Fixation in a Lumbar Degenerative Spondylolisthesis Finite Element Analysis Model
    Farooqi, Ali S.
    Narayanan, Rajkishen
    Canseco, Jose A.
    Vaccaro, Alexander R.
    WORLD NEUROSURGERY, 2024, 190 : E129 - E136