Breakage of cementless press-fit femoral stems following total hip arthroplasty in dogs: 14 cases (2013-2023)

被引:0
|
作者
Carvajal, Jose L. [1 ]
Karlin, William M. [2 ]
Marcellin-Little, Denis J. [3 ]
Kowaleski, Michael P. [2 ]
Verpaalen, Valentine D. [4 ]
Guiot, Laurent P. [5 ]
Chou, Po-Yen [3 ]
Barthelemy, Nicolas P. [6 ]
Lotsikas, Peter J. [7 ]
Kim, Stanley E. [1 ]
机构
[1] Univ Florida, Coll Vet Med, Dept Clin Sci, 2015 SW 16th Ave,POB 100126, Gainesville, FL 32610 USA
[2] Tufts Univ, Dept Clin Sci, Cummings Sch Vet Med, North Grafton, MA USA
[3] Univ Calif Davis, Dept Surg & Radiol Sci, Davis, CA USA
[4] Univ Georgia, Coll Vet Med, Dept Small Anim Med & Surg, Athens, GA USA
[5] ACCESS Anim Specialty Hosp, ACCESS Bone & Joint Ctr, Culver City, CA USA
[6] Univ Bristol, Langford Vets Small Anim Referral Hosp, Langford, England
[7] Skylos Sports Med, Woodstock, MD USA
关键词
COMPLICATIONS; REPLACEMENT; FAILURE;
D O I
10.1111/vsu.14227
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectiveTo report breakage of press-fit cementless femoral stems in dogs after total hip arthroplasty (THA).Study designRetrospective case series.AnimalsThirteen dogs (14 stems).MethodsMedical records were obtained for client-owned dogs that underwent THA between 2013 and 2023. Demographic data, implant type and size, time to stem breakage, and radiographic assessment of implant size were recorded. Implant size was compared with the manufacturers' guidelines based on body weight. Treatment-associated complications and overall outcomes were also recorded.ResultsFourteen broken stems were reported in 13 dogs. Thirteen were size #5, #6, or #7 Biologic Fixation (BFX) lateral bolt stems and one was a size #5 standard BFX stem. A +9 head was used in 5 of 11 cases with 17 mm diameter heads. The median time from THA to stem breakage was 522 days (interquartile range, 330-905 days). Ten of the 14 stems were radiographically undersized. The weights of 10 of 13 dogs were at, or exceeded, weight-limit guidelines. Eleven stems were revised with a new stem, two were explanted, and one was partially explanted. Major complications of revision included stem rebreakage, periprosthetic fracture, and pin and tension band-fixation failure. Full function was achieved in 9 of 10 dogs with revised stems based on owner and surgeon assessment.ConclusionMost of the stems that broke were BFX lateral bolt stems and were undersized both radiographically and in comparison with weight-limit guidelines. Revision can be successful, although the complication rate is high.Clinical significanceThe use of small, undersized BFX lateral bolt stems should be avoided.
引用
收藏
页码:561 / 572
页数:12
相关论文
共 50 条
  • [1] Global fit concept in revision hip arthroplasty for cementless press-fit femoral stems
    Canovas, F.
    LeBeguec, P.
    Batard, J.
    Gaillard, F.
    Dagneaux, L.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (04) : 579 - 581
  • [2] Risk Factors for Femoral Fracture after Canine Press-Fit Cementless Total Hip Arthroplasty
    Ganz, Seth Mathus
    Jackson, Joshua
    VanEnkevort, Bruce
    VETERINARY SURGERY, 2010, 39 (06) : 688 - 695
  • [3] Comparison of femoral stem subsidence between three types of press-fit cementless total hip replacement in dogs
    Mitchell, Megan M.
    Hudson, Caleb C.
    Beale, Brian S.
    VETERINARY SURGERY, 2020, 49 (04) : 787 - 793
  • [4] Treatment Outcomes for Periprosthetic Femoral Fractures in Cementless Press-Fit Total Hip Replacement
    Monotti, Isobel C.
    Preston, Christopher A.
    Kidd, Scott W.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 33 (05) : 370 - 376
  • [5] Complications of porous-coated press-fit cementless total hip replacement in dogs
    Kidd, Scott W.
    Preston, Christopher A.
    Moore, George E.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (05) : 402 - 408
  • [6] Cementless revision femoral stems application of press-fit principles and clinical outcomes
    François Canovas
    Sophie Putman
    Louis Dagneaux
    Lamine Chadli
    Pierre Le Béguec
    International Orthopaedics, 2019, 43 : 2261 - 2267
  • [7] Cementless revision femoral stems application of press-fit principles and clinical outcomes
    Canovas, Francois
    Putman, Sophie
    Dagneaux, Louis
    Chadli, Lamine
    Le Beguec, Pierre
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (10) : 2261 - 2267
  • [8] Cementless Tapered Femoral Stems for Total Hip Arthroplasty in Octogenarians
    Riley, Stephanie A.
    Spears, James R.
    Smith, Langan S.
    Mont, Michael A.
    Elmallah, Randa K.
    Cherian, Jeffrey J.
    Malkani, Arthur L.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (12): : 2810 - 2813
  • [9] Selecting a Press-fit Stem for Total Hip Arthroplasty: The Rationale and Evolution of the Modern Femoral Prosthesis
    Blankstein, Michael
    Haimes, Mark A.
    Nelms, Nathaniel J.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (20) : E1279 - E1290
  • [10] A New Classification System for Cementless Femoral Stems in Total Hip Arthroplasty
    Radaelli, Marco
    Buchalter, Daniel B.
    Mont, Michael A.
    Schwarzkopf, Ran
    Hepinstall, Matthew S.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (03): : 502 - 510