Breakage of cementless press-fit femoral stems following total hip arthroplasty in dogs: 14 cases (2013-2023)

被引:0
|
作者
Carvajal, Jose L. [1 ]
Karlin, William M. [2 ]
Marcellin-Little, Denis J. [3 ]
Kowaleski, Michael P. [2 ]
Verpaalen, Valentine D. [4 ]
Guiot, Laurent P. [5 ]
Chou, Po-Yen [3 ]
Barthelemy, Nicolas P. [6 ]
Lotsikas, Peter J. [7 ]
Kim, Stanley E. [1 ]
机构
[1] Univ Florida, Coll Vet Med, Dept Clin Sci, 2015 SW 16th Ave,POB 100126, Gainesville, FL 32610 USA
[2] Tufts Univ, Dept Clin Sci, Cummings Sch Vet Med, North Grafton, MA USA
[3] Univ Calif Davis, Dept Surg & Radiol Sci, Davis, CA USA
[4] Univ Georgia, Coll Vet Med, Dept Small Anim Med & Surg, Athens, GA USA
[5] ACCESS Anim Specialty Hosp, ACCESS Bone & Joint Ctr, Culver City, CA USA
[6] Univ Bristol, Langford Vets Small Anim Referral Hosp, Langford, England
[7] Skylos Sports Med, Woodstock, MD USA
关键词
COMPLICATIONS; REPLACEMENT; FAILURE;
D O I
10.1111/vsu.14227
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectiveTo report breakage of press-fit cementless femoral stems in dogs after total hip arthroplasty (THA).Study designRetrospective case series.AnimalsThirteen dogs (14 stems).MethodsMedical records were obtained for client-owned dogs that underwent THA between 2013 and 2023. Demographic data, implant type and size, time to stem breakage, and radiographic assessment of implant size were recorded. Implant size was compared with the manufacturers' guidelines based on body weight. Treatment-associated complications and overall outcomes were also recorded.ResultsFourteen broken stems were reported in 13 dogs. Thirteen were size #5, #6, or #7 Biologic Fixation (BFX) lateral bolt stems and one was a size #5 standard BFX stem. A +9 head was used in 5 of 11 cases with 17 mm diameter heads. The median time from THA to stem breakage was 522 days (interquartile range, 330-905 days). Ten of the 14 stems were radiographically undersized. The weights of 10 of 13 dogs were at, or exceeded, weight-limit guidelines. Eleven stems were revised with a new stem, two were explanted, and one was partially explanted. Major complications of revision included stem rebreakage, periprosthetic fracture, and pin and tension band-fixation failure. Full function was achieved in 9 of 10 dogs with revised stems based on owner and surgeon assessment.ConclusionMost of the stems that broke were BFX lateral bolt stems and were undersized both radiographically and in comparison with weight-limit guidelines. Revision can be successful, although the complication rate is high.Clinical significanceThe use of small, undersized BFX lateral bolt stems should be avoided.
引用
收藏
页码:561 / 572
页数:12
相关论文
共 50 条
  • [31] Cementless total hip arthroplasty for avascular necrosis of the femoral head following cardiac transplantation: report of two cases
    Antonopoulos, Athanasios
    Antoniou, Theofani
    Pollalis, Athanasios
    Sklitsi, Filio
    Economou, Alexandros
    Theodoraki, Kassiani
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2012, 17 (06) : 808 - 812
  • [32] Total hip arthroplasty revision using the press-fit CLS Spotorno cementless stem - Twenty-four hips followed between 1987 and 1998
    Tauber, C
    Kidron, A
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2000, 120 (3-4) : 209 - 211
  • [33] Component Alignment in Revision Total Knee Arthroplasty Using Diaphyseal Engaging Modular Offset Press-Fit Stems
    Nakasone, Cass K.
    Abdeen, Ayesha
    Khachatourians, Armond G.
    Sugimori, Tanzo
    Vince, Kelly G.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (08): : 1178 - 1181
  • [34] Comparison of Specific Femoral Short Stems and Conventional-Length Stems in Primary Cementless Total Hip Arthroplasty2
    Shin, Young-Soo
    Suh, Dong-Hun
    Park, Jong-Hoon
    Kim, Jeong-Lae
    Han, Seung-Beom
    ORTHOPEDICS, 2016, 39 (02) : E311 - E317
  • [35] Total hip arthroplasty revision using the press-fit CLS Spotorno cementless stem Twenty-four hips followed between 1987 and 1998
    C. Tauber
    A. Kidron
    Archives of Orthopaedic and Trauma Surgery, 2000, 120 : 209 - 211
  • [36] Nonmodular flexible press-fit cup in primary total hip arthroplasty - 15-year followup
    Berli, Bernhard J.
    Ping, Gu
    Dick, Walter
    Morscher, Erwin W.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (461) : 114 - 121
  • [37] Monobloc press-fit cups with large-diameter bearings are safe in revision total hip arthroplasty
    Synnott, Paul-Andre
    Sivaloganathan, Sivan
    Kiss, Marc-Olivier
    Binette, Benoit
    Morcos, Mina W.
    Vendittoli, Pascal-Andre
    ORTHOPEDIC REVIEWS, 2022, 14 (04)
  • [38] Tapered wedge stems decrease early postoperative subsidence following cementless total hip arthroplasty in Dorr type C femurs compared to fit-and-fill stems
    Satoshi Ikemura
    Goro Motomura
    Satoshi Hamai
    Masanori Fujii
    Shinya Kawahara
    Taishi Sato
    Daisuke Hara
    Kyohei Shiomoto
    Yasuharu Nakashima
    Journal of Orthopaedic Surgery and Research, 17
  • [39] Tapered wedge stems decrease early postoperative subsidence following cementless total hip arthroplasty in Dorr type C femurs compared to fit-and-fill stems
    Ikemura, Satoshi
    Motomura, Goro
    Hamai, Satoshi
    Fujii, Masanori
    Kawahara, Shinya
    Sato, Taishi
    Hara, Daisuke
    Shiomoto, Kyohei
    Nakashima, Yasuharu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [40] The Effect of Surgical Approach and Femoral Prosthesis Type on Revision Rates Following Total Hip Arthroplasty An Analysis of the Most Commonly Utilized Cementless Stems
    Hoskins, Wayne
    Rainbird, Sophia
    Peng, Yi
    Graves, Stephen E.
    Bingham, Roger
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2022, 104 (01): : 24 - 32