Multi-stage heat pump with two-phase injection for cold climate applications implementing natural refrigerants☆

被引:0
|
作者
Fix, Andrew [1 ]
Kang, Dana [1 ]
Siam, Md Mehrab Hossen [1 ]
Hwang, Yunho [1 ]
Radermacher, Reinhard [1 ]
机构
[1] Univ Maryland, Ctr Environm Energy Engn, College Pk, MD 20742 USA
关键词
Heat pump; Cold climate; Natural refrigerants; Two-phase injection; Efficiency; VAPOR-INJECTION; SCROLL COMPRESSOR; LIQUID INJECTION; SATURATION CYCLE; PERFORMANCE; SYSTEM; OPTIMIZATION; EXCHANGER; R410A; INTERMEDIATE;
D O I
10.1016/j.applthermaleng.2025.125474
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat pump adoption in cold climates is limited by various technical challenges, including heat capacity degradation, compressor deterioration, and frost accumulation on the outdoor heat exchanger. Furthermore, widespread adoption of heat pumps with high global warming potential presents a possible environmental concern. Thus, we present a heat pump concept termed the "saturation cycle," which uses numerous compression stages to improve energy efficiency and injects two-phase refrigerant between compression stages to dramatically reduce compressor discharge temperatures. Given the growing interest in heat pumps, there is a need for a straightforward framework for parametric evaluation of natural refrigerants in high-efficiency heat pump cycle architectures, like the saturation cycle, in adverse climates. This study develops a thermodynamic modeling framework and focuses on the application of natural refrigerants to explore the performance trends at extremely cold climates down to -25 degrees C. This study shows that a two-stage saturation cycle and four-stage saturation cycle can reduce the compressor discharge superheating by up to 51-57 % or 73-80 %, respectively, depending on the refrigerant. Furthermore, at -25 degrees C, a two-stage R-290 saturation cycle heat pump theoretically can use 25 % less power than a single-stage heat pump or can provide up to 59 % more heating capacity when using the same compressor power as the baseline single-stage heat pump. The exergetic parametric analyses show that twophase refrigerant injection fundamentally improves the thermodynamic performance of the heat pump, reducing overall exergy destruction by 10 % compared to a vapor-injection heat pump, compared at -25 degrees C. Thus, the saturation cycle is a promising heat pump cycle architecture for cold climate applications due to its superior energy savings (or capacity improvement) and substantial de-superheating capabilities.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Analysis of performance and economical efficiency of two-stage compression heat pump system with inter-stage injection in cold regions of northern China
    Xu Jin
    Zhe Wu
    Kuo Zhang
    Zhongyan Liu
    Wenpeng Hong
    Xiaoyi Li
    Building Simulation, 2019, 12 : 551 - 562
  • [32] Downward two-phase flow applications for a non-conventional heat pump (vol 27, pg 629, 2004)
    Arosio, S
    Carlevaro, R
    Guilizzoni, A
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (05): : 791 - 791
  • [33] Effect of split injection strategy of diesel fuel on multi-stage heat release and performance of a RCCI engine fueled with diesel and natural gas
    Yang, Liping
    Ji, Shuaizhuang
    Niu, Wenqing
    Zare, Ali
    Hunicz, Jacek
    Brown, Richard J.
    FUEL, 2024, 362
  • [34] Two-phase flow of refrigerants in 85 μm-wide multi-microchannels: Part II - Heat transfer with 35 local heaters
    Costa-Patry, Etienne
    Olivier, Jonathan
    Michel, Bruno
    Thome, John Richard
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2011, 32 (02) : 464 - 476
  • [35] Oil flooded compression cycle enhancement for two-stage heat pump in cold climate region: System design and theoretical analysis
    Luo, Baojun
    ENERGY CONVERSION AND MANAGEMENT, 2016, 115 : 52 - 59
  • [36] Performance of a refrigeration system with a two-phase CO2-based natural circulation loop for cold storage applications
    Das, Krushna Mohan
    Ramgopal, Maddali
    Guha, Abhijit
    Katu, Yogesh Arun
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 58
  • [37] The Comparison of Experiment Results and CFD Simulation in the Heat Pump System Using Thermobank and Two-Phase Ejector for Heating Room and Cold Storage
    Le Ngoc Cuong
    Oh, Jong-Taek
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2016, 24 (01)
  • [38] Analysis of two-phase injection heat pump using artificial neural network considering APF and LCCP under various weather conditions
    Kim, Dongwoo
    Song, Kang Sub
    Lim, Junyub
    Kim, Yongchan
    ENERGY, 2018, 155 : 117 - 127
  • [39] Experimental investigation of a novel two-stage heat recovery heat pump system employing the vapor injection compressor at cold ambience and high water temperature conditions
    Li, Yunhai
    Li, Zhaomeng
    Fan, Yi
    Zeng, Cheng
    Cui, Yu
    Zhao, Xudong
    Li, Jing
    Chen, Ying
    Chen, Jianyong
    Shen, Chao
    RENEWABLE ENERGY, 2023, 205 : 678 - 694
  • [40] Vapor-liquid two-phase flow and thermodynamic loss of multi-stage high temperature and pressure reducing valve based on evaporation model
    Si, Heyong
    Cao, Lihua
    Li, Pan
    Chen, Dongchao
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 147