Can EPID-based 2D in vivo dosimetry detect delivery errors in spine SBRT?

被引:0
|
作者
Maria Leo, Fatima [1 ]
Anson, Cristina [1 ]
Vivancos, Helena [1 ]
Perez-Alija, Jaime [1 ]
Gallego, Pedro [1 ]
Tejedor, Natalia [1 ]
Barcelo, Marta [1 ]
Ruiz, Agustin [1 ]
Dominguez, Alejandro [1 ]
Riu, Victor [1 ]
Carrasco, Pablo [1 ]
Jornet, Nuria [1 ]
机构
[1] Hosp Santa Creu & Sant Pau, Med Phys, Barcelona, Spain
关键词
In-vivo dosimetry (IVD); EPID; error detection;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
2505
引用
收藏
页码:S3347 / S3349
页数:4
相关论文
共 50 条
  • [21] A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetryA step to QA with in vivo EPID dosimetry
    Christos Moustakis
    Fatemeh Ebrahimi Tazehmahalleh
    Khaled Elsayad
    Francis Fezeu
    Sergiu Scobioala
    Strahlentherapie und Onkologie, 2020, 196 : 182 - 192
  • [22] EPID 2D transit In Vivo Dosimetry: Can relevant anatomy and positioning differences be detected?
    Jornet, N.
    Valverde, I.
    Espinosa, N.
    Latorre-Mussoll, A.
    Carrasco de Fez, P.
    Delgado, P.
    Perez-Alija, J.
    Gallego, P.
    Ruiz, A.
    Adria, M.
    Simon, P.
    Ribas Morales, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S724 - S725
  • [23] An EPID-based 3D patient dose verification method for SBRT-VMAT delivery
    McCowan, P.
    vanUytven, E.
    vanBeek, T.
    McCurdy, B.
    MEDICAL PHYSICS, 2014, 41 (08) : 2 - 2
  • [24] Error detection during VMAT delivery using EPID-based 3D transit dosimetry
    Mijnheer, B.
    Jomehzadeh, A.
    Gonzalez, P.
    Olaciregui-Ruiz, I
    Rozendaal, R.
    Shokrani, P.
    Spreeuw, H.
    Tielenburg, R.
    Mans, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 54 : 137 - 145
  • [25] Characterization of a new EPID-based system for in-vivo dosimetry in VMAT treatments
    Bresciani, S.
    Poli, M.
    Miranti, A.
    Maggio, A.
    Di Dia, A.
    Bracco, C.
    Stasi, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S736 - S737
  • [26] A 2D couch attenuation model for in vivo EPID transit dosimetry
    Olaciregui-Ruiz, I.
    Rozendaal, R.
    Mijnheer, B.
    Mans, A.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (02):
  • [27] EPID-based dosimetry and its relation to other 2D and 3D dose measurement techniques in radiation therapy
    Mijnheer, B.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [28] Clinical Implementation Of EPID-based Daily In Vivo Dose Verification System For SBRT Patients
    Asuni, G.
    vanBeek, T.
    McCowan, P.
    VanUytven, E.
    McCurdy, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S19 - S19
  • [29] EPID-Based in Vivo Dosimetry: The Next Step in Patient-Specific QA
    Mijnheer, B.
    Olaciregui-Ruiz, I.
    Rozendaal, R.
    Sonke, J-J
    Spreeuw, H.
    Tielenburg, R.
    van Herk, M.
    Mans, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [30] A Viable Approach to Patient Specific QA for Spine VMAT SRS Using EPID-Based Dosimetry
    Song, Y.
    Zhang, P.
    Li, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3742 - 3742