Assessment of Holmium:YAG, Pulsed-Thulium:YAG and Thulium Fiber Lasers for Urinary Stone Ablation. In Vitro Study

被引:0
|
作者
Sierra, Alba [1 ]
Panthier, Frederic [2 ]
Castillo, Esther [3 ]
Mercade, Asier [1 ]
Peri, Lluis [1 ]
Alcaraz, Antonio [1 ]
Traxer, Olivier [2 ]
Lopez, Juan Manuel [1 ]
Luque, Maria Pilar [1 ]
机构
[1] Univ Barcelona, Hosp Clin, Dept Urol, Barcelona, Spain
[2] Sorbonne Univ, Tenon Hosp, AP HP, Dept Urol, Paris, France
[3] Univ Barcelona, Barcelona, Spain
关键词
Holmium YAG; pulsed-thulium YAG; thulium fiber laser; laser efficiency; thermal damage; urinary stones; laser setting; laser parameters; LITHOTRIPSY; POWER; YAG;
D O I
10.1089/end.2024.0349
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the ablation speed (AS), laser efficiency and direct thermal lesions during urinary stone lithotripsy with the current available laser technologies: Holmium:YAG (Ho:YAG), pulsed-Thulium:YAG (p-Tm:YAG) and thulium fiber laser (TFL) in vitro using different laser settings. Materials and Methods: Ho:YAG, p-Tm:YAG, and TFL laser system were used in an in vitro ureteral model with a volume of 125 mm(3) Begostone. The following parameters were tested across all laser devices: 0.6J/10 Hz (6 W), 0.6 J/20 Hz (12 W), 1.5 J/10 Hz (15 W), and 1.5 J/20 Hz (30 W), employing short pulse width for all lasers and long pulse width for Ho:YAG and p-Tm:YAG. Ten participants conducted the experimental setup during 3-minutes laser on time, combining the laser technology, settings, and pulse widths, with a total of 20 different combinations. The efficiency, AS and ureteral damage resulting from each intervention were analyzed. Results: p-Tm:YAG and TFL demonstrated significantly higher efficiency compared with Ho:YAG (0.049 +/- 0.02 Delta gr/KJ and 0.042 +/- 0.01 Delta gr/KJ vs 0.029 +/- 0.01 Delta gr/KJ; p < 0.05). In all laser sources, as the power increases, the AS also increases (p < 0.05). Furthermore, only at high-energy settings (1.5 J) higher frequency led to increase AS (p < 0.05). Both, p-Tm:YAG and TFL exhibited higher AS compared to Ho:YAG (0.64 +/- 0.33 Delta gr/s and 0.62 +/- 0.31 Delta gr/s vs 0.44 +/- 0.22 Delta gr/s; p < 0.05). Regarding ureteral injuries, as the power increases, there is a higher chance of ureteral damage (p = 0.031). No differences were observed between laser technologies (p = 0.828). Conclusions: Both, p-Tm:YAG and TFL exhibited superior performances during laser lithotripsy compared with Ho:YAG, as they demonstrated higher efficiency and ablation speed. Thermal damage did not appear to be associated with specific laser equipment, but higher grades of lesions are described by increasing power.
引用
收藏
页码:1209 / 1216
页数:8
相关论文
共 50 条
  • [1] In Vitro Comparison of Pulsed-Thulium:YAG, Holmium:YAG, and Thulium Fiber Laser
    Chicaud, Marie
    Kutchukian, Stessy
    Berthe, Laurent
    Corrales, Mariela
    Solano, Catalina
    Candela, Luigi
    Doizi, Steeve
    Smith, Daron
    Traxer, Olivier
    Panthier, Frederic
    JOURNAL OF ENDOUROLOGY, 2024, 38 (12) : 1427 - 1435
  • [2] In-vitro comparison of stone ablation volume using Pulsed Thulium:YAG and modulated pulsed holmium: YAG lasers
    Balado, Bravo A. C.
    Sanchez-Puy, A.
    Izquierdo, P.
    Diana, P.
    Piana, A.
    Kanashiro, A. S.
    Balana, J.
    Millan, F. L.
    Gallioli, A.
    Gracia, S.
    Angerri, O.
    Emiliani, E.
    EUROPEAN UROLOGY, 2024, 85 : S1301 - S1302
  • [3] Fiber-optic manipulation of urinary stone phantoms using holmium:YAG and thulium fiber lasers
    Blackmon, Richard L.
    Case, Jason R.
    Trammell, Susan R.
    Irby, Pierce B.
    Fried, Nathaniel M.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (02)
  • [4] Understanding the ablation rate of Holmium:YAG and thulium fiber lasers. Perspectives from an in vitro study
    Basulto-Martinez, Mario
    Proietti, Silvia
    Pavia, Maria Pia
    Yeow, Yuyi
    Eisner, Brian H. H.
    Giusti, Guido
    UROLITHIASIS, 2023, 51 (01)
  • [5] Understanding the ablation rate of Holmium:YAG and thulium fiber lasers. Perspectives from an in vitro study
    Mario Basulto-Martínez
    Silvia Proietti
    Maria Pia Pavia
    Yuyi Yeow
    Brian H. Eisner
    Guido Giusti
    Urolithiasis, 51
  • [6] Comparison of Holmium: YAG and Thulium Fiber Lasers for Lithotripsy
    Blackmon, Richard L.
    Irby, Pierce B.
    Fried, Nathaniel M.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VI, 2010, 7548
  • [7] An in vitro analysis of holmium: YAG and thulium fiber laser ablation rates
    Basulto-Martinez, M.
    Proietti, S.
    Pavia, M. P.
    Rico, L.
    Yeow, Y.
    Flores-Tapia, J. P.
    Esqueda-Mendoza, A.
    Gaboardi, F.
    Giusti, G.
    EUROPEAN UROLOGY, 2021, 79 : S305 - S305
  • [8] Ablation rates with Holmium:YAG and Thulium Fiber Laser: Influence of the stone phantom homogeneity. An in vitro study
    Kutchukian, S.
    Doizi, S.
    Lapouge, P.
    Germain, T.
    Dragos, L.
    Berthe, L.
    Solano, C.
    Candela, L.
    Corrales, M.
    Chicaud, M.
    Traxer, O.
    Panthier, F.
    PROGRES EN UROLOGIE, 2023, 33 (8-9): : 456 - 462
  • [9] Comparison of holmium:yttrium-aluminium-garnet (YAG), thulium fiber laser, and pulsed thulium:YAG lasers on soft tissue: an ex vivo study
    Kutchukian, Stessy
    Chicaud, Marie
    Berthe, Laurent
    Coste, Frederic
    Lapouge, Pierre
    Alshehhi, Hussa
    Buob, David
    Traxer, Olivier
    Panthier, Frederic
    Doizi, Steeve
    BJU INTERNATIONAL, 2024, 134 (05) : 763 - 772
  • [10] Comparison of Holmium:YAG and Thulium Fiber Lasers on the Risk of Laser Fiber Fracture
    Uzan, Audrey
    Chiron, Paul
    Panthier, Frederic
    Haddad, Mattieu
    Berthe, Laurent
    Traxer, Olivier
    Doizi, Steeve
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (13)