Is thoron a problem in radon measurements with NRPB/SSI passive radon detectors-experimental study

被引:0
|
作者
Wasikiewicz, J. M. [1 ]
Dimitrova, I [2 ]
Ibrahimi, Z-f [1 ]
Georgiev, S. [2 ]
Mitev, K. [2 ]
Daraktchieva, Z. [1 ]
机构
[1] UK Hlth Secur Agcy, RCCE, Didcot OX11 0RQ, Oxon, England
[2] Sofia Univ St Kliment Ohridski, Fac Phys, Sofia 1164, Bulgaria
关键词
ATMOSPHERE; EXPOSURE;
D O I
10.1093/rpd/ncaf012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The UKHSA radon detectors with polyallyldiglycol carbonate sensing material produced from 2010 onward were used to confirm that they are purely radon detectors only with negligible interference from thoron presence. The statistical analysis of results, after following standard detector processing procedures, showed that such devices can only detect 2.4% +/- 0.3% of the total thoron activity concentration compared to the calibrated reference device. It was also demonstrated that thoron, unlike radon, can only travel a very short distance from the source to be effectively measured. Based on the above, it has been concluded that interference of thoron in radon measurement is negligible (within the statistical measurement error), and hence can be ignored in standard indoor and outdoor measurements.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Environmental Radioactivity Monitoring and Measurements: Radon and Thoron
    Janik, Miroslaw
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (15)
  • [22] Simultaneous measurement of radon, radon progeny and thoron concentrations using Makrofol-DE detectors
    Amgarou, K
    Font, L
    Domingo, C
    Fernández, F
    Baixeras, C
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 139 - 144
  • [23] AN INTERCOMPARISON OF DIFFERENT PASSIVE RADON DETECTORS
    AZIMIGARAKANI, D
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 259 - 262
  • [24] STUDY OF A PASSIVE DETECTOR FOR RETROSPECTIVE RADON MEASUREMENTS
    MEESEN, G
    POFFIJN, A
    UYTTENHOVE, J
    BUYSSE, J
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 591 - 594
  • [26] TRACK ETCH DETECTORS FOR RADON AND RADON-DAUGHTER MEASUREMENTS
    FLEISCHER, RL
    GINGRICH, JE
    HEALTH PHYSICS, 1979, 37 (06): : 825 - 825
  • [27] COMPARATIVE STUDY OF RADON AND THORON MEASUREMENTS IN FOUR ROMANIAN SHOW CAVES
    Burghele, B. D.
    Cucos, A.
    Papp, B.
    Dicu, T.
    Pressyanov, D.
    Dimitrov, D.
    Dimitrova, I.
    Constantin, S.
    RADIATION PROTECTION DOSIMETRY, 2017, 177 (1-2) : 181 - 185
  • [28] COMPARATIVE STUDY OF VARIOUS TECHNIQUES FOR ENVIRONMENTAL RADON, THORON AND PROGENY MEASUREMENTS
    Ramola, R. C.
    Prasad, Mukesh
    Rawat, Mukesh
    Dangwal, Anoop
    Gusain, G. S.
    Mishra, Rosaline
    Sahoo, S. K.
    Tokonami, S.
    RADIATION PROTECTION DOSIMETRY, 2015, 167 (1-3) : 22 - 28
  • [29] The influence of thoron and its progeny on radon measurements with CR39 detectors in diffusion chambers
    Nikezic, D
    Yu, KN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (01): : 175 - 180
  • [30] Measurements of radon, thoron and their progeny in Gifu prefecture, Japan
    Németh, C
    Tokonami, S
    Ishikawa, T
    Takahashi, H
    Zhuo, W
    Shimo, M
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 267 (01) : 9 - 12