Is thoron a problem in radon measurements with NRPB/SSI passive radon detectors-experimental study

被引:0
|
作者
Wasikiewicz, J. M. [1 ]
Dimitrova, I [2 ]
Ibrahimi, Z-f [1 ]
Georgiev, S. [2 ]
Mitev, K. [2 ]
Daraktchieva, Z. [1 ]
机构
[1] UK Hlth Secur Agcy, RCCE, Didcot OX11 0RQ, Oxon, England
[2] Sofia Univ St Kliment Ohridski, Fac Phys, Sofia 1164, Bulgaria
关键词
ATMOSPHERE; EXPOSURE;
D O I
10.1093/rpd/ncaf012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The UKHSA radon detectors with polyallyldiglycol carbonate sensing material produced from 2010 onward were used to confirm that they are purely radon detectors only with negligible interference from thoron presence. The statistical analysis of results, after following standard detector processing procedures, showed that such devices can only detect 2.4% +/- 0.3% of the total thoron activity concentration compared to the calibrated reference device. It was also demonstrated that thoron, unlike radon, can only travel a very short distance from the source to be effectively measured. Based on the above, it has been concluded that interference of thoron in radon measurement is negligible (within the statistical measurement error), and hence can be ignored in standard indoor and outdoor measurements.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] EFFECTS OF AIR EXCHANGE PROPERTY OF PASSIVE-TYPE RADON-THORON DISCRIMINATIVE DETECTORS ON PERFORMANCE OF RADON AND THORON MEASUREMENTS
    Omori, Y.
    Janik, M.
    Sorimachi, A.
    Ishikawa, T.
    Tokonami, S.
    RADIATION PROTECTION DOSIMETRY, 2012, 152 (1-3) : 140 - 145
  • [2] Contribution from thoron on the response of passive radon detectors
    Tokonami, S
    Yang, ML
    Sanada, T
    HEALTH PHYSICS, 2001, 80 (06): : 612 - 615
  • [3] RADON AND THORON MEASUREMENTS USING NUCLEAR TRACK DETECTORS
    MORSY, AA
    DURRANI, SA
    GEOPHYSICAL JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY, 1985, 81 (01): : 332 - 332
  • [4] ANOMALOUS RESULTS WITH THE WIDELY USED NRPB/SSI-TYPE PASSIVE RADON DOSEMETER
    Paridaens, J.
    RADIATION PROTECTION DOSIMETRY, 2010, 142 (2-4) : 347 - 353
  • [5] International intercomparisons of integrating radon/thoron detectors with the NIRS radon/thoron chambers
    Janik, M.
    Tokonami, S.
    Kranrod, C.
    Sorimachi, A.
    Ishikawa, T.
    Hassan, N. M.
    RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) : 436 - 439
  • [6] Tests of CDs/DVDs as Passive Radon and Thoron Detectors for Mines and Caves
    Pressyanov, D.
    Dimitrov, D.
    Georgiev, S.
    Dimitrova, I.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [7] A study on the thoron sensitivity of radon detectors available to Canadians
    Chen, Jing
    Moir, Deborah
    JOURNAL OF RADIOLOGICAL PROTECTION, 2012, 32 (04) : 419 - 425
  • [8] INTERCOMPARISON BETWEEN RADON PASSIVE AND ACTIVE MEASUREMENTS AND PROBLEMS RELATED TO THORON MEASUREMENTS
    Burghele, B.
    Cosma, C.
    ROMANIAN JOURNAL OF PHYSICS, 2013, 58 : S56 - S61
  • [9] Performance test of passive radon-thoron discriminative detectors on environmental parameters
    Sorimachi, Atsuyuki
    Tokonami, Shinji
    Omori, Yasutaka
    Ishikawa, Tetsuo
    RADIATION MEASUREMENTS, 2012, 47 (06) : 438 - 442
  • [10] A diffusion chamber for passive separated measurements of radon/thoron concentration in dwellings
    Nabil, F. Torabi
    Pooya, S. M. Hosseini
    Zafarghandi, M. Shamsaie
    Taheri, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 694 : 331 - 334