Design and operation of a whole-body MRI scanner without RF shielding

被引:0
|
作者
Biber, Stephan [1 ]
Kannengiesser, Stephan [1 ]
Nistler, Juergen [1 ]
Braun, Markus [1 ]
Blaess, Stefan [1 ]
Gebhardt, Matthias [1 ]
Grodzki, David [1 ]
Ritter, Dieter [1 ]
Seegerer, Georg [1 ]
Vester, Markus [1 ]
Schneider, Rainer [1 ]
机构
[1] Siemens Healthineers AG, Allee Roethelheimpk 2, D-91052 Erlangen, Germany
关键词
accessible MRI; noise cancellation; RF shielding; whole-body MRI;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate how a clinical MRI system can be operated without an RF cabin. Receive interference cancellation via signal processing and active transmit emission suppression are evaluated for mitigating image artifacts and achieving electromagnetic compatibility. Methods: A clinical whole-body MR scanner with B-0=0.55T was placed in an environment without RF shielding. The signals of 16 additional auxiliary receive antenna elements outside the scanner bore were used to remove interference from the wanted MR signal via a dedicated sidelobe cancellation algorithm. In vivo measurements with different MR sequences were performed in the presence of ambient RF noise and additional artificial interferers, covering brain and abdominal applications. To investigate the transmit electromagnetic compatibility, simulations with different auxiliary transmit antenna arrangements and body coil loading conditions were performed, and their emission suppression performance in the far field was evaluated. Results: The MR sidelobe cancellation algorithm successfully removed interference artifacts up to more than 3 times of the wanted MR image energy; difference images carried little to no visibly removed wanted signal. According to the simulations, electromagnetic compliance can be achieved with 32 or more auxiliary transmit antennas. The number and placement of sensor points are essential. Conclusions: A whole-body 0.55T MR scanner can be operated without RF shielding. Image artifacts from external interference can be removed, requiring only a modest number of auxiliary antennas. Electromagnetic compliance appears to be achievable using active transmit cancellation, but the required hardware efforts may not be practical.
引用
收藏
页码:1842 / 1855
页数:14
相关论文
共 50 条
  • [41] Clinical Application of Whole-body MRI
    Yi, Chin A.
    Lee, Kyung Soo
    Kim, Ji Hye
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2008, 51 (11): : 1034 - 1039
  • [43] Whole-body MRI as a screening tool?
    Ladd, Susanne C.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 70 (03) : 452 - 462
  • [44] Combined17O/1H MRI study in a whole-body scanner
    M. Kempka
    J. Hankiewicz
    D. Fiat
    Applied Magnetic Resonance, 2003, 24 : 409 - 415
  • [45] Characterization of acoustic noise and magnetic field fluctuations in a 4 T whole-body MRI scanner
    Mechefske, CK
    Wu, YH
    Rutt, B
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2002, 16 (2-3) : 459 - 473
  • [46] PERFORMANCE-CHARACTERISTICS OF A WHOLE-BODY PET SCANNER
    DEGRADO, TR
    TURKINGTON, TG
    WILLIAMS, JJ
    STEARNS, CW
    HOFFMAN, JM
    COLEMAN, RE
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (08) : 1398 - 1406
  • [47] Combined 17O/1H MRI study in a whole-body scanner
    Kempka, M
    Hankiewicz, J
    Fiat, D
    APPLIED MAGNETIC RESONANCE, 2003, 24 (3-4) : 409 - 415
  • [48] RADIATION PROTECTION REQUIREMENTS FOR A WHOLE-BODY CT SCANNER
    GROSS, GP
    MCCULLOUGH, EC
    RADIOLOGY, 1977, 122 (03) : 825 - 826
  • [49] A LINEAR WHOLE-BODY SCANNER FOR QUANTITATIVE POSITRON IMAGING
    OSTERTAG, H
    KUBLER, W
    KUBESCH, R
    LORENZ, WJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 174 - 178
  • [50] Electromagnetic Structure Design of the Whole-Body 14 T MRI Magnet
    Xu, Aihua
    Wu, Kaihong
    Cai, Fuhai
    Zhang, Bo
    Tang, Zhipeng
    Shi, Yi
    Sang, Xiaohu
    Luo, Chunhui
    Shi, Kunju
    Shi, Dongli
    Ye, Sui
    Zhou, Jinyang
    Wu, Yu
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (03) : 1 - 5