Design and operation of a whole-body MRI scanner without RF shielding

被引:0
|
作者
Biber, Stephan [1 ]
Kannengiesser, Stephan [1 ]
Nistler, Juergen [1 ]
Braun, Markus [1 ]
Blaess, Stefan [1 ]
Gebhardt, Matthias [1 ]
Grodzki, David [1 ]
Ritter, Dieter [1 ]
Seegerer, Georg [1 ]
Vester, Markus [1 ]
Schneider, Rainer [1 ]
机构
[1] Siemens Healthineers AG, Allee Roethelheimpk 2, D-91052 Erlangen, Germany
关键词
accessible MRI; noise cancellation; RF shielding; whole-body MRI;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate how a clinical MRI system can be operated without an RF cabin. Receive interference cancellation via signal processing and active transmit emission suppression are evaluated for mitigating image artifacts and achieving electromagnetic compatibility. Methods: A clinical whole-body MR scanner with B-0=0.55T was placed in an environment without RF shielding. The signals of 16 additional auxiliary receive antenna elements outside the scanner bore were used to remove interference from the wanted MR signal via a dedicated sidelobe cancellation algorithm. In vivo measurements with different MR sequences were performed in the presence of ambient RF noise and additional artificial interferers, covering brain and abdominal applications. To investigate the transmit electromagnetic compatibility, simulations with different auxiliary transmit antenna arrangements and body coil loading conditions were performed, and their emission suppression performance in the far field was evaluated. Results: The MR sidelobe cancellation algorithm successfully removed interference artifacts up to more than 3 times of the wanted MR image energy; difference images carried little to no visibly removed wanted signal. According to the simulations, electromagnetic compliance can be achieved with 32 or more auxiliary transmit antennas. The number and placement of sensor points are essential. Conclusions: A whole-body 0.55T MR scanner can be operated without RF shielding. Image artifacts from external interference can be removed, requiring only a modest number of auxiliary antennas. Electromagnetic compliance appears to be achievable using active transmit cancellation, but the required hardware efforts may not be practical.
引用
收藏
页码:1842 / 1855
页数:14
相关论文
共 50 条
  • [21] EMI WHOLE-BODY SCANNER IN LIVER IMAGING
    KREEL, L
    BRITISH JOURNAL OF RADIOLOGY, 1978, 51 (602): : 143 - 144
  • [22] PRELIMINARY EVALUATION OF EMI WHOLE-BODY SCANNER
    KREEL, L
    JOURNAL BELGE DE RADIOLOGIE, 1976, 59 (05): : 477 - 477
  • [23] EVALUATION OF TUMOR EXTENSION BY WHOLE-BODY SCANNER
    LAGERGREN, C
    UROLOGICAL RESEARCH, 1978, 6 (04): : 191 - 192
  • [24] THE INDICATIONS OF THE WHOLE-BODY SCANNER WITH THE EXCEPTION OF ONCOLOGY
    LAVALJEANTET, M
    BUY, JN
    GAZETTE MEDICALE DE FRANCE, 1982, 89 (08): : 823 - &
  • [25] SPECIAL INDICATIONS FOR USING WHOLE-BODY SCANNER
    ROTHE, R
    SCHERER, U
    LISSNER, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1977, 127 (06): : 530 - 535
  • [26] DESIGN AND OPERATION OF A WHOLE-BODY DYNAMIC INHALATION EXPOSURE SYSTEM
    YADAV, PC
    PATEL, TS
    JAYPAUL, N
    DEWAN, A
    KASHYAP, SK
    JOURNAL OF ENVIRONMENTAL BIOLOGY, 1994, 15 (01): : 7 - 14
  • [27] EVALUATION AND APPLICATION OF WHOLE-BODY SCINTIGRAPHIC SCANNER
    COOKE, MBD
    LOPEZMAJ.V
    KAPLAN, E
    JOURNAL OF NUCLEAR MEDICINE, 1971, 12 (06) : 426 - &
  • [28] EARLY EXPERIENCE WITH ELSCINT WHOLE-BODY SCANNER
    COALTER, GC
    MONKS, GK
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1976, 6 (03): : 274 - 274
  • [29] COMPARISON OF A NEW WHOLE-BODY SCANNER WITH A LARGE CRYSTAL SCANNING CAMERA IN WHOLE-BODY IMAGING
    ELL, PJ
    MYERS, MJ
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1977, 2 (04): : 281 - 284
  • [30] Design Study of a Whole-Body PET Scanner With Improved Spatial and Timing Resolution
    Surti, Suleman
    Shore, Adam R.
    Karp, Joel S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3220 - 3226