Efficacy and safety of a novel polytetrafluoroethylene-coated self-expandable metal stent for distal malignant biliary obstruction

被引:0
|
作者
Nakagawa, Hiroki [1 ,2 ]
Takeda, Tsuyoshi [1 ]
Okamoto, Takeshi [1 ]
Hirai, Tatsuki [1 ]
Mie, Takafumi [1 ]
Furukawa, Takaaki [1 ]
Kasuga, Akiyoshi [1 ]
Sasaki, Takashi [1 ]
Ozaka, Masato [1 ]
Matsuda, Takahisa [2 ]
Igarashi, Yoshinori [2 ]
Sasahira, Naoki [1 ]
机构
[1] Canc Inst Hosp Japanese Fdn Canc Res, Dept Hepatobiliary Pancreat Med, 3-8-31 Ariake, Koto, Tokyo 1358550, Japan
[2] Toho Univ, Omori Med Ctr, Dept Internal Med, Div Gastroenterol & Hepatol, Tokyo, Japan
来源
DEN OPEN | 2025年 / 5卷 / 01期
关键词
adverse event; distal malignant biliary obstruction; polytetrafluoroethylene; recurrent biliary obstruction; self-expandable metal stent; RISK-FACTORS; MIGRATION;
D O I
10.1002/deo2.70010
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Stent migration and sludge formation remain significant problems associated with covered self-expandable metal stents (CSEMSs). The EGIS biliary stent fully covered flare type (EGIS biliary stent), a new type of polytetrafluoroethylene-coated self-expandable metal stent with low axial force and an anti-migration system, was developed to overcome these disadvantages. We conducted this study to evaluate the efficacy and safety of this stent in comparison with conventional CSEMS (c-CSEMS). Methods We retrospectively analyzed consecutive patients with unresectable pancreatic cancer who received initial CSEMS for distal malignant biliary obstruction. The primary outcome was time to recurrent biliary obstruction (RBO). Secondary outcomes included technical success rate, functional success rate, stent-related adverse events, causes of RBO, and re-intervention. Results A total of 40 patients were included (EGIS group: 20; c-CSEMS group: 20). The technical and functional success rates were similar between the two groups. Stent-related adverse event rates (20% vs. 15%, p > 0.99) and overall RBO rates (56% vs. 50%, p > 0.99) were not significantly different between the two groups. Stent migration was the most common cause of RBO in the EGIS group, while stent occlusion was in the c-CSEMS group. The median time to RBO (102 vs. 434 days, p = 0.10) was not significantly different between the two groups. Endoscopic transpapillary re-intervention was successful in most patients in both groups. Conclusions The EGIS biliary stent was not associated with a longer time to RBO compared to c-CSEMS. Further improvements, especially against stent migration, are needed to improve its efficacy.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Clinical efficacy of self-expandable colonic metal stent in patients with malignant colonic obstruction
    Park, Byung Kyu
    Jeon, Han Ho
    Won, Sun Yeong
    Cho, Yong Suk
    Hunseo, Jeong
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2015, 30 : 259 - 260
  • [32] SEMS and Sensibility: Self-Expandable Metal Stents for Malignant Biliary Obstruction—Are Stent Characteristics Important?
    Evangelos Kalaitzakis
    Digestive Diseases and Sciences, 2019, 64 : 2376 - 2378
  • [33] Efficacy and Safety of Fluoroscopy-Guided Self-Expandable Metal Stent Placement for Treatment of Malignant Colorectal Obstruction
    Zhaofei Zeng
    Yang Liu
    Ketong Wu
    Dan Li
    Haiyang Lai
    Bo Zhang
    Digestive Diseases and Sciences, 2023, 68 : 939 - 947
  • [34] Efficacy and Safety of Fluoroscopy-Guided Self-Expandable Metal Stent Placement for Treatment of Malignant Colorectal Obstruction
    Zeng, Zhaofei
    Liu, Yang
    Wu, Ketong
    Li, Dan
    Lai, Haiyang
    Zhang, Bo
    DIGESTIVE DISEASES AND SCIENCES, 2023, 68 (03) : 939 - 947
  • [35] RISK FACTOR OF RECURRENT BILIARY OBSTRUCTION OF COVERED SELF-EXPANDABLE METALLIC STENT FOR UNRESECTABLE DISTAL MALIGNANT BILIARY STRICTURE
    Tanoue, Kojiro
    Maruyama, Hirotsugu
    Yamamoto, Kei
    Manabe, Taku
    Kakiya, Yuki
    Hayashi, Kappei
    Yamamura, Masafumi
    Ominami, Masaki
    Fukunaga, Shusei
    Nadatani, Yuji
    Otani, Koji
    Tanaka, Fumio
    Taira, Koichi
    Kamata, Noriko
    Nagami, Yasuaki
    Tanigawa, Tetsuya
    Watanabe, Toshio
    Fujiwara, Yasuhiro
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB344 - AB345
  • [36] EFFICACY OF PARTIALLY COVERED VERSUS UNCOVERED SELF-EXPANDABLE METAL STENTS IN THE PALLIATIVE TREATMENT OF MALIGNANT DISTAL BILIARY OBSTRUCTION
    Yoo, Kyo-Sang
    Kim, Jeongwoo
    GASTROINTESTINAL ENDOSCOPY, 2024, 99 (06) : AB653 - AB654
  • [37] Antireflux valve metal stent versus conventional self-expandable metal stent in distal malignant biliary obstruction: a systematic review and meta-analysis
    Renno, Anas
    Abdel-Aziz, Yousef
    Ahmed, Tamer
    Alastal, Yaseen
    Toseef, Javaid
    Al-Abboodi, Yasir
    Nawras, Ali
    ANNALS OF GASTROENTEROLOGY, 2019, 32 (06): : 605 - 613
  • [38] Efficacy of Partially Covered vs Uncovered Self-Expandable Metal Stents in the Palliative Treatment of Malignant Distal Biliary Obstruction
    Yoo, Kyo-Sang
    Kim, Jeongwoo
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2024, 119 (10S): : S106 - S107
  • [39] Biliary drainage with a modified fully covered self-expandable metallic stent for potentially resectable distal malignant biliary obstruction
    Moon, Jong Ho
    Ko, Bong Min
    Hong, Su Jin
    Choi, Hyun Jong
    Kim, Dong Choon
    Koo, Hyun Cheol
    Lee, Tae Hoon
    Cha, Sang-Woo
    Cho, Young Deok
    Park, Sang-Heum
    Kim, Sun-Joo
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 : 86 - 86
  • [40] Safety and efficacy of a partially covered self-expandable metal stent in benign pyloric obstruction
    Jun Heo
    Min Kyu Jung