A comparison of McGrath video laryngoscope and Macintosh laryngoscope during nasotracheal intubation: A randomised controlled study

被引:0
|
作者
Gangishetty, Alekhya [1 ]
Jonnavithula, Nirmala [1 ]
Geetha, Singam [1 ]
Muthyala, Harshini [1 ]
Peetha, Hareesh [1 ]
机构
[1] Nizams Inst Med Sci, Dept Anaesthesia & Crit Care, Hyderabad 500082, India
关键词
MacIntosh; Faciomaxillary; McGrath; Intubation; Laryngoscope; Airway; CONTROLLED-TRIAL; DIFFICULT; VIDEOLARYNGOSCOPE; MANAGEMENT;
D O I
10.1177/17504589241270202
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Nasotracheal intubation is challenging for anaesthesiologists in faciomaxillary injuries due to the anticipated difficult airways. The effectiveness of a non-channelled McGrath video laryngoscope was compared with a conventional Macintosh laryngoscope during nasotracheal intubation.Methods: Sixty American Society of Anaesthesiologists I-II patients aged between 18 and 60 years of both sexes undergoing elective faciomaxillary surgeries from September 2019 to February 2020 were prospectively randomised into two groups (Macintosh laryngoscope Group, McGrath video laryngoscope Group) of 30. The primary outcome was ease of intubation (Modified Intubation Difficulty Scale) and Nasotracheal intubation time (T1 time: from nostril to nasopharynx, T2 time: from nasopharynx until the first ETCO2, total time: T1 + T2). The secondary outcomes were Cormac Lehane grade, additional manoeuvres requirement, intubation failure, tracheostomy incidence and associated complications.Results: T1, T2 and total (T1 + T2) time (mean +/- SD) were statistically prolonged in the McGrath video laryngoscope than Macintosh laryngoscope group, with p = 0.044, p = 0.000 and p = 0.000, respectively. The McGrath video laryngoscope facilitated a better laryngoscopic view (p = 0.002), favourable intubation difficulty scale scores, less lifting force (p = 0.002), reduced lip trauma (p = 0.002) and decreased Magill's forceps use (p = 0.002) than the Macintosh laryngoscope group.Conclusion: Despite longer intubation time, the non-channelled McGrath video laryngoscope offered favourable intubating conditions with superior glottis view, less lifting force and reduced Magill's forceps requirement, causing decreased airway trauma, lower intubation difficulty scale scores than Macintosh laryngoscope for nasotracheal intubation.
引用
收藏
页码:378 / 383
页数:6
相关论文
共 50 条
  • [31] COMPARISON OF THE KING VISION VIDEO LARYNGOSCOPE WITH THE MACINTOSH LARYNGOSCOPE
    Murphy, Laurel D.
    Kovacs, George J.
    Reardon, Peter M.
    Law, John Adam
    JOURNAL OF EMERGENCY MEDICINE, 2014, 47 (02): : 239 - 245
  • [32] Comparison of Airtraq with Macintosh Laryngoscope for Endotracheal Intubation in Paediatric Patients: A Randomised Controlled Trial
    Dwivedi, Yogita
    Jain, Ankit
    Yadav, Vijay Pratap
    Agarwal, Atiharsh Mohan
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (03) : UC16 - UC18
  • [33] A Comparison of the C-MAC Video Laryngoscope to the Macintosh Direct Laryngoscope for Intubation in the Emergency Department
    Sakles, John C.
    Mosier, Jarrod
    Chiu, Stephen
    Cosentino, Mari
    Kalin, Leah
    ANNALS OF EMERGENCY MEDICINE, 2012, 60 (06) : 739 - 748
  • [34] Comparison of the McGRATH™ Video Laryngoscope and Macintosh Laryngoscope for Orotracheal Intubation in a Simulated Difficult Airway Scenario: An Open-Label, Randomized Clinical Trial
    Kim, Jong-Yeop
    Park, Seonghyeok
    Oh, Minho
    Choi, Jong-Bun
    John, Hyun-Ji
    Lee, Soo-Kyung
    Choi, Yi-Hwa
    MEDICINA-LITHUANIA, 2023, 59 (02):
  • [35] Intraocular pressure changes: the McGrath video laryngoscope vs the Macintosh Laryngoscope; a randomized trial
    Karaman, Tugba
    Dogru, Serkan
    Karaman, Serkan
    Demir, Selim
    Kaya, Ziya
    Suren, Mustafa
    Arid, Semih
    Kahveci, Mursel
    Alim, Sait
    JOURNAL OF CLINICAL ANESTHESIA, 2016, 34 : 358 - 364
  • [36] The Accuracy of Tests Used to Predict Difficult Airway and a Comparison of Macintosh Laryngoscope to Video Laryngoscope for Intubation
    Mingir, Tarkan
    Kitapcioglu, Dilek
    Turgut, Namigar
    Yumru, Cengiz
    KUWAIT MEDICAL JOURNAL, 2015, 47 (03): : 201 - 209
  • [37] Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial
    Pournajafian, Ali Reza
    Ghodraty, Mohammad Reza
    Faiz, Seyed Hamid Reza
    Rahimzadeh, Poupak
    Goodarzynejad, Hamidreza
    Dogmehchi, Enseyeh
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2014, 16 (04)
  • [38] IS AIRTRAQ VIDEO LARYNGOSCOPE A BETTER ALTERNATIVE TO CONVENTIONAL MACINTOSH DIRECT LARYNGOSCOPE DURING ROUTINE INTUBATION? A COMPARATIVE STUDY
    Mahmood, Syed Fazal
    Padmanabha, S.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (93): : 15903 - 15904
  • [39] Endotracheal Intubation Using the Macintosh Laryngoscope or KingVision Video Laryngoscope during Uninterrupted Chest Compression
    Gaszynska, Ewelina
    Gaszynski, Tomasz
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [40] Comparison of the conventional Macintosh laryngoscope, the Pentax Airwayscope, and the McGrath MAC video laryngoscope under restricted cervical motion: a manikin study
    Kotera, Atsushi
    Irie, Hiroki
    Iwashita, Shinsuke
    Taniguchi, Junichi
    Kasaoka, Shunji
    Kinoshita, Yoshihiro
    ACUTE MEDICINE & SURGERY, 2015, 2 (02): : 138 - 142