A comparison of McGrath video laryngoscope and Macintosh laryngoscope during nasotracheal intubation: A randomised controlled study

被引:0
|
作者
Gangishetty, Alekhya [1 ]
Jonnavithula, Nirmala [1 ]
Geetha, Singam [1 ]
Muthyala, Harshini [1 ]
Peetha, Hareesh [1 ]
机构
[1] Nizams Inst Med Sci, Dept Anaesthesia & Crit Care, Hyderabad 500082, India
关键词
MacIntosh; Faciomaxillary; McGrath; Intubation; Laryngoscope; Airway; CONTROLLED-TRIAL; DIFFICULT; VIDEOLARYNGOSCOPE; MANAGEMENT;
D O I
10.1177/17504589241270202
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Nasotracheal intubation is challenging for anaesthesiologists in faciomaxillary injuries due to the anticipated difficult airways. The effectiveness of a non-channelled McGrath video laryngoscope was compared with a conventional Macintosh laryngoscope during nasotracheal intubation.Methods: Sixty American Society of Anaesthesiologists I-II patients aged between 18 and 60 years of both sexes undergoing elective faciomaxillary surgeries from September 2019 to February 2020 were prospectively randomised into two groups (Macintosh laryngoscope Group, McGrath video laryngoscope Group) of 30. The primary outcome was ease of intubation (Modified Intubation Difficulty Scale) and Nasotracheal intubation time (T1 time: from nostril to nasopharynx, T2 time: from nasopharynx until the first ETCO2, total time: T1 + T2). The secondary outcomes were Cormac Lehane grade, additional manoeuvres requirement, intubation failure, tracheostomy incidence and associated complications.Results: T1, T2 and total (T1 + T2) time (mean +/- SD) were statistically prolonged in the McGrath video laryngoscope than Macintosh laryngoscope group, with p = 0.044, p = 0.000 and p = 0.000, respectively. The McGrath video laryngoscope facilitated a better laryngoscopic view (p = 0.002), favourable intubation difficulty scale scores, less lifting force (p = 0.002), reduced lip trauma (p = 0.002) and decreased Magill's forceps use (p = 0.002) than the Macintosh laryngoscope group.Conclusion: Despite longer intubation time, the non-channelled McGrath video laryngoscope offered favourable intubating conditions with superior glottis view, less lifting force and reduced Magill's forceps requirement, causing decreased airway trauma, lower intubation difficulty scale scores than Macintosh laryngoscope for nasotracheal intubation.
引用
收藏
页码:378 / 383
页数:6
相关论文
共 50 条
  • [21] Comparison of the McGrath® MAC video laryngoscope with direct Macintosh laryngoscopy for novice laryngoscopists in children without difficult intubation: A randomised controlled trial
    Giraudon, Antoine
    Bordes-Demolis, Maryline
    Blondeau, Barbara
    de Panthou, Nadia Sibai
    Ferrand, Nathan
    Bello, Maeva
    Dahlet, Victoria
    Semjen, Francois
    Biais, Matthieu
    Nouette-Gaulain, Karine
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2017, 36 (05) : 261 - 265
  • [22] A Comparison of the GlideScope With the Macintosh Laryngoscope for Nasotracheal Intubation in Patients With Ankylosing Spondylitis
    Xu Lili
    Hu Zhiyong
    Shen Jianjun
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2014, 26 (01) : 27 - 31
  • [23] Evaluation of the McGrath MAC™ and Macintosh laryngoscope for tracheal intubation
    Kriegel, Marc
    Noppens, Rildiger R.
    BRITISH JOURNAL OF ANAESTHESIA, 2020, 125 (01) : E209 - E209
  • [24] Nasotracheal intubation performance with the mcgrath videolaryngoscope versus macintosh laryngoscope in oral and maxillofacial surgery- An observational study
    Sengel, N.
    Karabulut, G.
    Kavuncuoglu, D.
    Selmi, N.
    Sivgin, V
    Toprak, M.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2022, 25 (05) : 683 - 689
  • [25] Airtraq laryngoscope has an advantage over Macintosh laryngoscope for nasotracheal intubation by novice laryngoscopists
    Yoshihiro Hirabayashi
    Norimasa Seo
    Journal of Anesthesia, 2009, 23 : 172 - 173
  • [26] Airtraq laryngoscope has an advantage over Macintosh laryngoscope for nasotracheal intubation by novice laryngoscopists
    Hirabayashi, Yoshihiro
    Seo, Norimasa
    JOURNAL OF ANESTHESIA, 2009, 23 (01) : 172 - 173
  • [27] Comparison of BPLTM Video Laryngoscope and Macintosh Laryngoscope Guided Throat Packing for Head and Neck Surgeries: A Randomised Controlled Study
    Mitragotri, Milon Vasant
    Kurdi, Madhuri
    Ladhad, Dharmesh Arvind
    Raddi, Prema
    Kurugodiyavar, Mahesh D.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (04) : UC36 - UC40
  • [28] A randomized controlled trial comparing the ease of tracheal intubation using a McGrath MAC laryngoscope and a standard Macintosh laryngoscope
    Foulds, L.
    Wallace, C.
    McLeod, G.
    McGuire, B.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (06) : E905 - E905
  • [29] Circulatory responses to nasotracheal intubation:: comparison of GlideScope® videolaryngoscope and Macintosh direct laryngoscope
    Xue Fu-Shan
    Li Xuan-Ying
    Liu Qian-Jin
    Liu He-Ping
    Yang Quan-Yong
    Xu Ya-Chao
    Liao Xu
    Liu Yi
    CHINESE MEDICAL JOURNAL, 2008, 121 (14) : 1290 - 1296