Automated liver magnetic resonance elastography quality control and liver stiffness measurement using deep learning

被引:0
|
作者
Ozkaya, Efe [1 ,2 ]
Nieves-Vazquez, Heriberto A. [3 ]
Yuce, Murat [1 ,2 ]
Yasokawa, Kazuya [1 ,2 ]
Altinmakas, Emre [1 ,2 ]
Ueda, Jun [4 ]
Taouli, Bachir [1 ,2 ]
机构
[1] Icahn Sch Med Mt Sinai, Biomed Engn & Imaging Inst, New York, NY 10029 USA
[2] Icahn Sch Med Mt Sinai, Dept Diagnost Mol & Intervent Radiol, New York, NY 10029 USA
[3] Georgia Inst Technol, Dept Biomed Engn, Atlanta, GA USA
[4] Georgia Inst Technol, Sch Mech Engn, Atlanta, GA USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Magnetic resonance elastography; Deep learning; Quality control; MR ELASTOGRAPHY; DISEASE;
D O I
10.1007/s00261-025-04883-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeMagnetic resonance elastography (MRE) measures liver stiffness for fibrosis staging, but its utility can be hindered by quality control (QC) challenges and measurement variability. The objective of the study was to fully automate liver MRE QC and liver stiffness measurement (LSM) using a deep learning (DL) method.MethodsIn this retrospective, single center, IRB-approved human study, a curated dataset involved 897 MRE magnitude slices from 146 2D MRE scans [1.5 T and 3 T MRI, 2D Gradient Echo (GRE), and 2D Spin Echo-Echo Planar Imaging (SE-EPI)] of 69 patients (37 males, mean age 51.6 years). A SqueezeNet-based binary QC model was trained using combined and individual inputs of MRE magnitude slices and their 2D Fast-Fourier transforms to detect artifacts from patient motion, aliasing, and blurring. Three independent observers labeled MRE magnitude images as 0 (non-diagnostic quality) or 1 (diagnostic quality) to create a reference standard. A 2D U-Net segmentation model was trained on diagnostic slices with liver masks to support LSM. Intersection over union between the predicted segmentation and confidence masks identified measurable areas for LSM on elastograms. Cohen's unweighted Kappa coefficient, mean LSM error (%), and intra-class correlation coefficient were calculated to compare the DL-assisted approach with the observers' annotations. An efficiency analysis compared the DL-assisted vs manual LSM durations.ResultsThe top QC ensemble model (using MRE magnitude alone) achieved accuracy, precision, and recall of 0.958, 0.982, and 0.886, respectively. The mean LSM error between the DL-assisted approach and the reference standard was 1.9% +/- 4.6%. DL-assisted approach completed LSM for 29 diagnostic slices in under 1 s, compared to 20 min manually.ConclusionAn automated DL-based classification of liver MRE diagnostic quality, liver segmentation, and LSM approach demonstrates a promising high performance, with potential for clinical adoption.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Weight Loss Decreases Magnetic Resonance Elastography Estimated Liver Stiffness in Nonalcoholic Fatty Liver Disease
    Patel, Niraj S.
    Hooker, Jonathan
    Gonzalez, Monica
    Bhatt, Archana
    Nguyen, Phirum
    Ramirez, Kimberly
    Richards, Lisa
    Rizo, Emily
    Hernandez, Carolyn
    Kisseleva, Tatiana
    Schnabl, Bernd
    Brenner, David
    Sirlin, Claude B.
    Loomba, Rohit
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2017, 15 (03) : 463 - 464
  • [42] Advances in Magnetic Resonance Elastography of Liver
    Li, Jiahui
    Venkatesh, Sudhakar Kundapur
    Yin, Meng
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2020, 28 (03) : 331 - +
  • [43] Measurement of stiffness changes in immobilized muscle using magnetic resonance elastography
    Muraki, Takayuki
    Domire, Zachary J.
    McCullough, Matthew B.
    Chen, Qingshan
    An, Kai-Nan
    CLINICAL BIOMECHANICS, 2010, 25 (05) : 499 - 503
  • [44] Learning curve and interobserver reproducibility evaluation of liver stiffness measurement by transient elastography
    Boursler, Jerome
    Konate, Anselme
    Guilluy, Marine
    Gorea, Gabriella
    Sawadogo, Apollinalre
    Quemener, Emmanuel
    Oberti, Frederic
    Reaud, Stephane
    Hubert-Fouchard, Isabelle
    Dib, Nina
    Cales, Paul
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2008, 20 (07) : 693 - 701
  • [45] Prediction of major complications after hepatectomy using liver stiffness values determined by magnetic resonance elastography
    Sato, N.
    Kenjo, A.
    Kimura, T.
    Okada, R.
    Ishigame, T.
    Kofunato, Y.
    Shimura, T.
    Abe, K.
    Ohira, H.
    Marubashi, S.
    BRITISH JOURNAL OF SURGERY, 2018, 105 (09) : 1192 - 1199
  • [46] Liver stiffness measured by magnetic resonance elastography as a risk factor for hepatocellular carcinoma: a preliminary case–control study
    Utaroh Motosugi
    Tomoaki Ichikawa
    Tsuyota Koshiishi
    Katsuhiro Sano
    Hiroyuki Morisaka
    Shintaro Ichikawa
    Nobuyuki Enomoto
    Masanori Matsuda
    Hideki Fujii
    Tsutomu Araki
    European Radiology, 2013, 23 : 156 - 162
  • [47] Liver Stiffness Measurement by Transient Elastography in Clinical Practice
    Sporea, Ioan
    Sirli, Roxana
    Deleanu, Alexandra
    Popescu, Alina
    Cornianu, Marioara
    JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2008, 17 (04) : 395 - 399
  • [48] Longitudinal association of magnetic resonance elastography-associated liver stiffness with complications and mortality
    Higuchi, Mayu
    Tamaki, Nobuharu
    Kurosaki, Masayuki
    Inada, Kento
    Kirino, Sakura
    Yamashita, Koji
    Hayakawa, Yuka
    Osawa, Leona
    Takaura, Kenta
    Maeyashiki, Chiaki
    Kaneko, Shun
    Yasui, Yutaka
    Takahashi, Yuka
    Tsuchiya, Kaoru
    Nakanishi, Hiroyuki
    Itakura, Jun
    Loomba, Rohit
    Enomoto, Nobuyuki
    Izumi, Namiki
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2022, 55 (03) : 292 - 301
  • [49] Liver Stiffness by Magnetic Resonance Elastography Predicts Future Cirrhosis, Decompensation, and Death in NAFLD
    Gidener, Tolga
    Ahmed, Omar T.
    Larson, Joseph J.
    Mara, Kristin C.
    Therneau, Terry M.
    Venkatesh, Sudhakar K.
    Ehman, Richard L.
    Yin, Meng
    Allen, Alina M.
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2021, 19 (09) : 1915 - +
  • [50] Normative values for magnetic resonance elastography-based liver stiffness in a healthy population
    Obrzut, Marzanna
    Atamaniuk, Vitaliy
    Obrzut, Bogdan
    Ehman, Richard
    Cholewa, Marian
    Rzucidlo, Mateusz
    Pozaruk, Andrii
    Gutkowski, Krzysztof
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2019, 129 (05): : 321 - 326