Assessment of scattered and leakage radiation from ultra-portable X-ray systems in chest imaging: An independent study

被引:0
|
作者
Paulis, Leonie E. [1 ,2 ,3 ]
Schnerr, Roald S. [1 ,4 ]
Halton, Jarred [1 ]
Qin, Zhi Zhen [2 ]
Chua, Arlene [5 ]
机构
[1] Medecins Sans Frontieres Int, Amsterdam, Netherlands
[2] Dept Digital Hlth, Amsterdam, Netherlands
[3] Maxima Med Ctr, Dept Med Phys, Veldhoven, Netherlands
[4] Maastricht Univ, Dept Radiol & Nucl Med, Med Ctr, Maastricht, Netherlands
[5] Medecins Sans Frontieres Int, Geneva, Switzerland
来源
PLOS GLOBAL PUBLIC HEALTH | 2025年 / 5卷 / 01期
关键词
D O I
10.1371/journal.pgph.0003986
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Ultraportable (UP) X-ray devices are ideal to use in community-based settings, particularly for chest X-ray (CXR) screening of tuberculosis (TB). Unfortunately, there is insufficient guidance on the radiation safety of these devices. This study aims to determine the radiation dose by UP X-ray devices to both the public and radiographers compared to international dose limits. Radiation dose measurements were performed with four UP X-ray devices that met international criteria, utilizing a clinically representative CXR set-up made with a thorax phantom. Scatter and leakage radiation dose were measured at various positions surrounding the phantom and X-ray tube, respectively. These measurements were used to calculate yearly radiation doses for different scenarios based on the median of all UP X-ray devices. From the yearly scatter doses, the minimum distances from the phantom needed to stay below the international public dose limit (1 mSv/year) were calculated. This distance was longest in the direction back towards the X-ray tube and shortest to the left/right sides of the phantom, e.g., 4.5 m and 2.5 m resp. when performing 50 exams/day, at 90kV, 2.5 mAs and source skin distance (SSD) 1 m. Additional calculations including leakage radiation were conducted at a typical radiographer position (i.e., behind the X-ray tube), with a correction factor for wearing a lead apron. At 2 m behind the X-ray tube, a radiographer wearing a lead apron could perform 106 exams/day at 2.5 mAs and 29 exams/day at 10 mAs (90kV, SSD 1 m), while keeping his/her radiation dose below the public dose limit (1 mSv/year) and well below the radiographer dose limit (20 mSv/year). In most CXR screening scenarios, the radiation dose of UP X-ray devices can be kept below 1 mSv/year by employing basic radiation safety rules on time, distance and shielding and using appropriate CXR exposure parameters.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Study of the X-ray energy utilization efficiency of the X-ray digital imaging systems in industrial applications
    Li Ruihong
    Han Yueping
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (01): : 368 - 372
  • [32] A study and optimization of lumbar spine X-ray imaging systems
    McVey, G
    Sandborg, M
    Dance, DR
    Carlsson, GA
    BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (903): : 177 - 188
  • [33] Early user experience and lessons learned using ultra-portable digital X-ray with computer-aided detection (DXR-CAD) products: A qualitative study from the perspective of healthcare providers
    Qin, Zhi Zhen
    Barrett, Rachael
    del Mar Castro, Maria
    Zaidi, Sarah
    Codlin, Andrew J.
    Creswell, Jacob
    Denkinger, Claudia M.
    PLOS ONE, 2023, 18 (02):
  • [34] Observing scattered X-ray radiation from gamma-ray bursts: A way to measure their collimation angles
    Sazonov, S.Yu. (sazonov@mpa-garching.mpg.de), 1600, EDP Sciences (399):
  • [35] X-ray diffraction radiation from ultra-relativistic charged particles
    Zhevago, NK
    Glebov, VI
    PHYSICS LETTERS A, 2003, 309 (3-4) : 311 - 319
  • [36] Observing scattered X-ray radiation from gamma-ray bursts: A way to measure their collimation angles
    Sazonov, SY
    Sunyaev, AA
    ASTRONOMY & ASTROPHYSICS, 2003, 399 (02) : 505 - 509
  • [37] CCD developments in x-ray imaging from synchrotron radiation sources
    Castelli, CM
    Ashton, JE
    Pool, PJ
    DEVELOPMENTS IN X-RAY TOMOGRAPHY, 1997, 3149 : 92 - 100
  • [38] Dark-field chest X-ray imaging for the assessment of COVID-19-pneumonia
    Manuela Frank
    Florian T. Gassert
    Theresa Urban
    Konstantin Willer
    Wolfgang Noichl
    Rafael Schick
    Manuel Schultheiss
    Manuel Viermetz
    Bernhard Gleich
    Fabio De Marco
    Julia Herzen
    Thomas Koehler
    Klaus Jürgen Engel
    Bernhard Renger
    Felix G. Gassert
    Andreas Sauter
    Alexander A. Fingerle
    Bernhard Haller
    Marcus R. Makowski
    Daniela Pfeiffer
    Franz Pfeiffer
    Communications Medicine, 2
  • [39] Synchrotron-based scattered radiation from phantom materials used in X-ray CT
    Rao, Donepudi V.
    Swapna, Medasani
    Cesareo, Roberto
    Brunetti, Antonio
    Akatsuka, Tako
    Yuasa, Tetsuya
    Takeda, Tohoru
    Gigante, Giovanni E.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2010, 18 (03) : 327 - 337
  • [40] Dark-field chest X-ray imaging for the assessment of COVID-19-pneumonia
    Frank, Manuela
    Gassert, Florian T.
    Urban, Theresa
    Willer, Konstantin
    Noichl, Wolfgang
    Schick, Rafael
    Schultheiss, Manuel
    Viermetz, Manuel
    Gleich, Bernhard
    De Marco, Fabio
    Herzen, Julia
    Koehler, Thomas
    Engel, Klaus Juergen
    Renger, Bernhard
    Gassert, Felix G.
    Sauter, Andreas
    Fingerle, Alexander A.
    Haller, Bernhard
    Makowski, Marcus R.
    Pfeiffer, Daniela
    Pfeiffer, Franz
    COMMUNICATIONS MEDICINE, 2022, 2 (01):