摘要
Objective To determine the optimal virtual monoenergy for viewing the bowel at photon-counting CT enterography using quantitative assessment of mural attenuation, contrast-to-noise ratio, signal-to-noise ratio and noise. Methods This study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. Consecutive adults (>= 18 years) who underwent photon-counting CT enterography from 5/1/2022-5/31/2022 with available Spectral Postprocessing (SPP) images for retrospective virtual monoenergy creation were identified. Nine virtual monoenergetic series (40-120 keV, 10 keV increments) were created. Two region-of-interest measurements were placed in the stomach wall, jejunum wall, ileum wall, and each psoas muscle by two radiologists on 0.6 mm images in PACS. Region-of-interests were copied to other virtual monoenergies to ensure identical placement and size. Attenuation (HU) and noise (HU standard deviation) were recorded from each region-of-interest. Signal-to-noise ratio and contrast-to-noise ratio were computed for stomach, jejunum, ileum, and all bowel combined. Pairwise comparisons for attenuation, noise, signal-to-noise ratio and contrast-to-noise ratio for each virtual monoenergy were performed with ANOVA. A p <.05 indicated statistical significance. Results 50 patients (32 female; mean[SD] age: 57 years) were included. Attenuation and noise for all bowel regions were highest at 40 keV with statistically significant pairwise comparisons from 40 to 70 keV (all p <.05), but similar for 70-120 keV (all p >.05). Signal-to-noise ratio was similar from 40 to 70 keV (all p >.05) for all bowel regions. Contrast-to-noise ratio decreased with increasing keV. Contrast-to-noise ratio was similar for all bowel at 40 keV and 50 keV (p =.06), for stomach from 40 to 70 keV (all p >.05), for jejunum from 40 to 50 keV (p =.21), and for ileum from 40 to 60 keV (all p >.05). Conclusion 50 keV virtual monoenergetic images from photon-counting CT enterography optimizes contrast-to-noise ratio while mitigating noise and should routinely be utilized for bowel assessment at photon-counting CT enterography. As most photon-counting CT users primarily interpret virtual monoenergetic images in clinical practice, knowledge of the optimal virtual monoenergy can inform protocol development.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Optimal virtual monoenergy for the detection of pancreatic adenocarcinoma during the pancreatic parenchymal phase on photon counting CT
    Ruff, Andrew
    Li, Xiaochun
    Goldberg, Judith D.
    Ehrhart, Mark
    Ginocchio, Luke
    Smereka, Paul
    O'Donnell, Thomas
    Dane, Bari
    ABDOMINAL RADIOLOGY, 2025,
  • [2] Development and Clinical Applications of a Virtual Imaging Framework for Optimizing Photon-counting CT
    Abadi, Ehsan
    McCabe, Cindy
    Harrawood, Brian
    Sotoudeh-Paima, Saman
    Segars, W. Paul
    Samei, Ehsan
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [3] Optimizing Photon-Counting Detector CT for Imaging Intracranial Aneurysms
    Rajendran, Kishore
    Madhavan, Ajay A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (10) : 1458 - 1460
  • [4] Virtual monoenergetic imaging in photon-counting CT of the head and neck
    Farhadi, Faraz
    Sahbaee, Pooyan
    Rajagopal, Jayasai R.
    Nikpanah, Moozhan
    Saboury, Babak
    Gutjahr, Ralf
    Biassou, Nadia M.
    Shah, Ritu
    Flohr, Thomas G.
    Samei, Ehsan
    Pritchard, William F.
    Malayeri, Ashkan A.
    Bluemke, David A.
    Jones, Elizabeth C.
    CLINICAL IMAGING, 2023, 102 : 109 - 115
  • [5] Virtual Noncontrast Abdominal Imaging with Photon-counting Detector CT
    Mergen, Victor
    Racine, Damien
    Jungblut, Lisa
    Sartoretti, Thomas
    Bickel, Steven
    Monnin, Pascal
    Higashigaito, Kai
    Martini, Katharina
    Alkadhi, Hatem
    Euler, Andre
    RADIOLOGY, 2022, 305 (01) : 106 - 114
  • [6] Imaging Inflammatory Bowel Disease with CT and MR Enterography
    Starakiewicz P.
    Grand D.J.
    Current Radiology Reports, 2013, 1 (4) : 277 - 285
  • [7] Photon-counting Detector CT: Initial Analysis of Virtual Noncontrast Imaging
    Sosna, Jacob
    RADIOLOGY, 2022, 305 (01) : 115 - 116
  • [8] Cardiac imaging with photon counting CT
    Flohr, Thomas
    Schmidt, Bernhard
    Ulzheimer, Stefan
    Alkadhi, Hatem
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1152):
  • [9] Optimal Selection of Thresholds for Photon Counting CT
    O'Donnell, Thomas
    Schoeck, Friederike
    Cheheltani, Rabee
    Cormode, David
    Fayad, Zahi A.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [10] Photon-counting CT to Virtual Noncontrast CT Images
    Pourmorteza, Amir
    RADIOLOGY, 2023, 306 (01) : 205 - 206