Digital versus speculum-based balloon catheter insertion for labor induction: a systematic review and meta-analysis

被引:1
|
作者
Seo, Densearn [1 ,2 ,3 ]
Kaur, Rashvinder [3 ]
Ponganam, Meghna Prasannan [4 ]
Sam, Kah Wai [5 ]
Hill, Maclean [6 ]
Davies-Tuck, Miranda [1 ,7 ]
Warty, Ritesh Rikain [1 ,3 ]
Smith, Vinayak [1 ,3 ]
Tan, Thiam Chye [8 ,9 ]
Fox, Deborah [10 ]
Palmer, Kirsten R. [1 ,11 ]
机构
[1] Monash Univ, Fac Med Nursing & Hlth Sci, Monash Med Ctr, Dept Obstet & Gynaecol, 246 Clayton Rd, Clayton, Vic 3168, Australia
[2] Monash Univ, Fac Med Nursing & Hlth Sci, Sch Clin Sci, 27 Rainforest Walk, Clayton, Vic 3168, Australia
[3] Gravida Hlth Pty Ltd, Wheelers Hill, Vic 3150, Australia
[4] Monash Sch Med, Fac Med Nursing & Hlth Sci, 27 Rainforest Walk, Clayton, Vic 3168, Australia
[5] Queensland Hlth, Gold Coast Univ Hosp, 1 Hosp Blvd, Southport, Qld 4215, Australia
[6] Mercy Hosp Women, 163 Studley Rd, Heidelberg, Vic 3084, Australia
[7] Hudson Inst Med Res, 27-31 Wright St, Clayton, Vic 3168, Australia
[8] Duke NUS Med Sch, 8 Coll Rd, Singapore 169857, Singapore
[9] Mt Elizabeth Novena Hosp, 38 Irrawaddy Rd, Singapore 329563, Singapore
[10] Univ Technol Sydney, Fac Hlth, Collect Midwifery Child & Family Hlth, Ultimo, NSW, Australia
[11] Monash Hlth, Monash Womens, 246 Clayton Rd, Clayton, Vic 3168, Australia
基金
英国医学研究理事会;
关键词
cervical ripening; maternal satisfaction; obstetrics; pain assessment; patient preferences; procedural safety; procedural time;
D O I
10.1016/j.ajogmf.2024.101519
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVES: Induction of labor is commonly undertaken when ongoing pregnancy poses a risk to either the mother or fetus. Often cervical preparation is required with mechanical methods increasingly popular due to their improved safety. This study evaluates the efficacy, safety, and acceptability of digital versus speculum-based balloon insertion for cervical preparation, aiming to identify gaps and inform future research. DATA SOURCE: PubMed, Ovid MEDLINE, EMBASE, and Scopus were searched from database inception until 30 June 2023. STUDY ELIGIBILITY CRITERIA: Included studies were randomized controlled trials comparing digital versus speculum-based insertion of catheterrelated balloons for labor induction in individuals with viable singleton pregnancies, in both inpatient and outpatient settings, written in English. Exclusions included studies not using cervical balloons, comparisons to nonballoon methods, nonhuman studies, and nonprimary literature like guidelines, reviews, commentaries, and opinion pieces. METHODS: Title and abstract screening were performed by 4 authors. Full-text articles were assessed against inclusion criteria. Selection was agreed upon by consensus among 3 authors, with a fourth consulted for disputes. The risk of bias was assessed using the Cochrane Risk of Bias Tool 2.0 for randomized trials. A meta-analysis was also performed. RESULTS: Out of 3397 studies, 4 met the inclusion criteria, all being randomized controlled trials with some concerns in at least one domain but no high risk of bias. Two studies found digital insertion significantly less painful than speculum-based insertion (P<.001), while one reported no difference (P=.72). Maternal satisfaction was comparable, with one study favoring digital insertion (P=.011). Meta-analysis findings for other outcome measures suggest no difference between speculum or digital insertion. However, due to substantial heterogeneity, findings for procedural time, time from induction to delivery, and epidural rate should be cautiously interpreted. CONCLUSIONS: Digital insertion for cervical preparation appears associated with reduced pain and higher patient acceptability compared to speculum-based insertion. Additionally, efficacy and safety were comparable, indicating it is a preferable option for clinical use. There was no difference in other procedural, obstetric, or neonatal outcomes, however, more rigorous research employing standardized outcome measures is needed to facilitate a clinically meaningful interpretation.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A Systematic Review and Meta-analysis of Basket or Balloon Catheter for the Retrieval of Choledocholithiasis
    Elsnhory, Ahmed Bostamy
    Mandour, Omar Amgad
    Montaser, Ahmed Gamal
    Kereet, Ibrahim Mahmoud
    Rezk, Hazem Salah
    Madhoon, Hossam Waleed
    Rabea, Randa Kamal
    Ragab, Khaled Mohamed
    Gbreel, Mohamed Ibrahim
    INDIAN JOURNAL OF SURGERY, 2023, 85 (02) : 241 - 250
  • [22] Infectious morbidity of speculum versus digital examinations in preterm prelabor rupture of membranes: a systematic review and meta-analysis
    Ayyar, Archana
    Moufarrij, Sara
    Turrentine, Mark
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2022, 35 (25): : 8905 - 8911
  • [23] Intracervical Foley catheter balloon versus dinoprostone insert for induction cervical ripening A systematic review and meta-analysis of randomized controlled trials
    Zhu, Lixia
    Zhang, Cong
    Cao, Fang
    Liu, Qin
    Gu, Xing
    Xu, Jianhao
    Li, Jianqing
    MEDICINE, 2018, 97 (48)
  • [24] Digital versus speculum-guided catheter balloon insertion for cervical ripening in multiparas: A randomized controlled trial
    Abu Shqara, Raneen
    Nakhlah, Yara
    Haj, Habib
    Markdorf, Sofya
    Lowenstein, Lior
    Wolf, Maya
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (01) : S540 - S541
  • [25] Double-balloon catheter versus dinoprostone insert for labour induction: a meta-analysis
    Liu, Yi-Ran
    Pu, Cai-Xiu
    Wang, Xiao-Yan
    Wang, Xue-Yan
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2019, 299 (01) : 7 - 12
  • [26] Double-balloon catheter versus dinoprostone insert for labour induction: a meta-analysis
    Yi-Ran Liu
    Cai-Xiu Pu
    Xiao-Yan Wang
    Xue-Yan Wang
    Archives of Gynecology and Obstetrics, 2019, 299 : 7 - 12
  • [27] ADVANCED LAPAROSCOPIC PERITONEAL DIALYSIS CATHETER INSERTION: SYSTEMATIC REVIEW AND META-ANALYSIS
    Shrestha, Badri M.
    Shrestha, Donna
    Kumar, Avneesh
    Shrestha, Alice
    Boyes, Simon A.
    Wilkie, Martin E.
    PERITONEAL DIALYSIS INTERNATIONAL, 2018, 38 (03): : 163 - 171
  • [28] PERITONEAL DIALYSIS CATHETER INSERTION WITH OR WITHOUT OMENTECTOMY: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Kim, Jin Kyu
    Lolas, Marisol
    Keefe, Daniel
    Rickard, Mandy
    Yadav, Priyank
    Lorenzo, Armando
    Chua, Michael
    JOURNAL OF UROLOGY, 2021, 206 : E653 - E654
  • [29] Single balloon versus double balloon bipedicular kyphoplasty: a systematic review and meta-analysis
    Jing, Zehao
    Dong, Jianli
    Li, Zhengwei
    Nan, Feng
    EUROPEAN SPINE JOURNAL, 2018, 27 (10) : 2550 - 2564
  • [30] Single balloon versus double balloon bipedicular kyphoplasty: a systematic review and meta-analysis
    Zehao Jing
    Jianli Dong
    Zhengwei Li
    Feng Nan
    European Spine Journal, 2018, 27 : 2550 - 2564