Digital versus speculum-based balloon catheter insertion for labor induction: a systematic review and meta-analysis

被引:1
|
作者
Seo, Densearn [1 ,2 ,3 ]
Kaur, Rashvinder [3 ]
Ponganam, Meghna Prasannan [4 ]
Sam, Kah Wai [5 ]
Hill, Maclean [6 ]
Davies-Tuck, Miranda [1 ,7 ]
Warty, Ritesh Rikain [1 ,3 ]
Smith, Vinayak [1 ,3 ]
Tan, Thiam Chye [8 ,9 ]
Fox, Deborah [10 ]
Palmer, Kirsten R. [1 ,11 ]
机构
[1] Monash Univ, Fac Med Nursing & Hlth Sci, Monash Med Ctr, Dept Obstet & Gynaecol, 246 Clayton Rd, Clayton, Vic 3168, Australia
[2] Monash Univ, Fac Med Nursing & Hlth Sci, Sch Clin Sci, 27 Rainforest Walk, Clayton, Vic 3168, Australia
[3] Gravida Hlth Pty Ltd, Wheelers Hill, Vic 3150, Australia
[4] Monash Sch Med, Fac Med Nursing & Hlth Sci, 27 Rainforest Walk, Clayton, Vic 3168, Australia
[5] Queensland Hlth, Gold Coast Univ Hosp, 1 Hosp Blvd, Southport, Qld 4215, Australia
[6] Mercy Hosp Women, 163 Studley Rd, Heidelberg, Vic 3084, Australia
[7] Hudson Inst Med Res, 27-31 Wright St, Clayton, Vic 3168, Australia
[8] Duke NUS Med Sch, 8 Coll Rd, Singapore 169857, Singapore
[9] Mt Elizabeth Novena Hosp, 38 Irrawaddy Rd, Singapore 329563, Singapore
[10] Univ Technol Sydney, Fac Hlth, Collect Midwifery Child & Family Hlth, Ultimo, NSW, Australia
[11] Monash Hlth, Monash Womens, 246 Clayton Rd, Clayton, Vic 3168, Australia
基金
英国医学研究理事会;
关键词
cervical ripening; maternal satisfaction; obstetrics; pain assessment; patient preferences; procedural safety; procedural time;
D O I
10.1016/j.ajogmf.2024.101519
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVES: Induction of labor is commonly undertaken when ongoing pregnancy poses a risk to either the mother or fetus. Often cervical preparation is required with mechanical methods increasingly popular due to their improved safety. This study evaluates the efficacy, safety, and acceptability of digital versus speculum-based balloon insertion for cervical preparation, aiming to identify gaps and inform future research. DATA SOURCE: PubMed, Ovid MEDLINE, EMBASE, and Scopus were searched from database inception until 30 June 2023. STUDY ELIGIBILITY CRITERIA: Included studies were randomized controlled trials comparing digital versus speculum-based insertion of catheterrelated balloons for labor induction in individuals with viable singleton pregnancies, in both inpatient and outpatient settings, written in English. Exclusions included studies not using cervical balloons, comparisons to nonballoon methods, nonhuman studies, and nonprimary literature like guidelines, reviews, commentaries, and opinion pieces. METHODS: Title and abstract screening were performed by 4 authors. Full-text articles were assessed against inclusion criteria. Selection was agreed upon by consensus among 3 authors, with a fourth consulted for disputes. The risk of bias was assessed using the Cochrane Risk of Bias Tool 2.0 for randomized trials. A meta-analysis was also performed. RESULTS: Out of 3397 studies, 4 met the inclusion criteria, all being randomized controlled trials with some concerns in at least one domain but no high risk of bias. Two studies found digital insertion significantly less painful than speculum-based insertion (P<.001), while one reported no difference (P=.72). Maternal satisfaction was comparable, with one study favoring digital insertion (P=.011). Meta-analysis findings for other outcome measures suggest no difference between speculum or digital insertion. However, due to substantial heterogeneity, findings for procedural time, time from induction to delivery, and epidural rate should be cautiously interpreted. CONCLUSIONS: Digital insertion for cervical preparation appears associated with reduced pain and higher patient acceptability compared to speculum-based insertion. Additionally, efficacy and safety were comparable, indicating it is a preferable option for clinical use. There was no difference in other procedural, obstetric, or neonatal outcomes, however, more rigorous research employing standardized outcome measures is needed to facilitate a clinically meaningful interpretation.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Speculum versus digital insertion of Foley catheter for induction of labor in Nulliparas with unripe cervix: a randomized controlled trial
    Hang Min Chia
    Peng Chiong Tan
    Sze Ping Tan
    Mukhri Hamdan
    Siti Zawiah Omar
    BMC Pregnancy and Childbirth, 20
  • [12] Inpatient Versus Outpatient Labor Induction: A Systematic Review and Meta-analysis
    D'Souza, Rohan D.
    Khan, Maria
    Hashimi, Farahnosh
    OBSTETRICS AND GYNECOLOGY, 2019, 133 : 67S - 67S
  • [13] Increased single-balloon Foley catheter volume for induction of labor and time to delivery: a systematic review and meta-analysis
    Schoen, Corina N.
    Saccone, Gabriele
    Backley, Sami
    Sandberg, Evelien M.
    Gu, Ning
    Delaney, Shani
    Berghella, Vincenzo
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2018, 97 (09) : 1051 - 1060
  • [14] Outcomes of Outpatient Versus Inpatient Induction of Labor: A Systematic Review and Meta-Analysis
    Mustafa, Mohammed
    Babiker, Mohamed
    Abusin, Fatema
    Mohammed, Tamador
    Awadalla, Tarig
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)
  • [15] Assessment of pain in women randomly allocated to speculum or digital insertion of the Foley catheter for induction of labor
    Jonsson, Maria
    Hellgren, Charlotte
    Wiberg-Itzel, Eva
    Akerud, Helena
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2011, 90 (09) : 997 - 1004
  • [16] Six vs 12-hour balloon catheter placement for the induction of labor: a systematic review and meta-analysis of randomized controlled trials
    Rashid, Attyia
    Imran, Muhammad
    Ali, Shujaat
    Mehmood, Areeba Mariam
    Khalil, Saba
    Farooq, Dawood Azam
    Kamran, Ateeba
    Zamir, Shamaila
    Khan, Ubaid
    Abuelazm, Mohamed
    AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM, 2024, 6 (11)
  • [17] Labor induction versus expectant management for postterm pregnancies: A systematic review with meta-analysis
    Sanchez-Ramos, L
    Olivier, F
    Delke, I
    Kaunitz, AM
    OBSTETRICS AND GYNECOLOGY, 2003, 101 (06): : 1312 - 1318
  • [18] Double balloon is not superior to single balloon trans-cervical catheter for induction of labor: a meta-analysis
    Katukuri, Vivek
    Blue, Nathan R.
    Holbrook, Bradley D.
    Chao, Conrad R.
    Rayburn, William F.
    Blackstone, Jacquelyn A.
    Mozurkewich, Ellen L.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2017, 216 (01) : S434 - S434
  • [19] A Systematic Review and Meta-analysis of Basket or Balloon Catheter for the Retrieval of Choledocholithiasis
    Ahmed Bostamy Elsnhory
    Omar Amgad Mandour
    Ahmed Gamal Montaser
    Ibrahim Mahmoud kereet
    Hazem Salah Rezk
    Hossam Waleed Madhoon
    Randa Kamal Rabea
    Khaled Mohamed Ragab
    Mohamed Ibrahim Gbreel
    Indian Journal of Surgery, 2023, 85 : 241 - 250
  • [20] Outpatient Cervical Ripening With a Balloon Catheter: Systematic Review and Meta-analysis
    Pierce-Williams, Rebecca
    Harper, Lorie
    Kuper, Spencer
    Sciscione, Anthony
    Berghella, Vincenzo
    Lesser, Henry
    OBSTETRICS AND GYNECOLOGY, 2020, 135 : 29S - 29S