Digital versus speculum-based balloon catheter insertion for labor induction: a systematic review and meta-analysis

被引:1
|
作者
Seo, Densearn [1 ,2 ,3 ]
Kaur, Rashvinder [3 ]
Ponganam, Meghna Prasannan [4 ]
Sam, Kah Wai [5 ]
Hill, Maclean [6 ]
Davies-Tuck, Miranda [1 ,7 ]
Warty, Ritesh Rikain [1 ,3 ]
Smith, Vinayak [1 ,3 ]
Tan, Thiam Chye [8 ,9 ]
Fox, Deborah [10 ]
Palmer, Kirsten R. [1 ,11 ]
机构
[1] Monash Univ, Fac Med Nursing & Hlth Sci, Monash Med Ctr, Dept Obstet & Gynaecol, 246 Clayton Rd, Clayton, Vic 3168, Australia
[2] Monash Univ, Fac Med Nursing & Hlth Sci, Sch Clin Sci, 27 Rainforest Walk, Clayton, Vic 3168, Australia
[3] Gravida Hlth Pty Ltd, Wheelers Hill, Vic 3150, Australia
[4] Monash Sch Med, Fac Med Nursing & Hlth Sci, 27 Rainforest Walk, Clayton, Vic 3168, Australia
[5] Queensland Hlth, Gold Coast Univ Hosp, 1 Hosp Blvd, Southport, Qld 4215, Australia
[6] Mercy Hosp Women, 163 Studley Rd, Heidelberg, Vic 3084, Australia
[7] Hudson Inst Med Res, 27-31 Wright St, Clayton, Vic 3168, Australia
[8] Duke NUS Med Sch, 8 Coll Rd, Singapore 169857, Singapore
[9] Mt Elizabeth Novena Hosp, 38 Irrawaddy Rd, Singapore 329563, Singapore
[10] Univ Technol Sydney, Fac Hlth, Collect Midwifery Child & Family Hlth, Ultimo, NSW, Australia
[11] Monash Hlth, Monash Womens, 246 Clayton Rd, Clayton, Vic 3168, Australia
基金
英国医学研究理事会;
关键词
cervical ripening; maternal satisfaction; obstetrics; pain assessment; patient preferences; procedural safety; procedural time;
D O I
10.1016/j.ajogmf.2024.101519
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVES: Induction of labor is commonly undertaken when ongoing pregnancy poses a risk to either the mother or fetus. Often cervical preparation is required with mechanical methods increasingly popular due to their improved safety. This study evaluates the efficacy, safety, and acceptability of digital versus speculum-based balloon insertion for cervical preparation, aiming to identify gaps and inform future research. DATA SOURCE: PubMed, Ovid MEDLINE, EMBASE, and Scopus were searched from database inception until 30 June 2023. STUDY ELIGIBILITY CRITERIA: Included studies were randomized controlled trials comparing digital versus speculum-based insertion of catheterrelated balloons for labor induction in individuals with viable singleton pregnancies, in both inpatient and outpatient settings, written in English. Exclusions included studies not using cervical balloons, comparisons to nonballoon methods, nonhuman studies, and nonprimary literature like guidelines, reviews, commentaries, and opinion pieces. METHODS: Title and abstract screening were performed by 4 authors. Full-text articles were assessed against inclusion criteria. Selection was agreed upon by consensus among 3 authors, with a fourth consulted for disputes. The risk of bias was assessed using the Cochrane Risk of Bias Tool 2.0 for randomized trials. A meta-analysis was also performed. RESULTS: Out of 3397 studies, 4 met the inclusion criteria, all being randomized controlled trials with some concerns in at least one domain but no high risk of bias. Two studies found digital insertion significantly less painful than speculum-based insertion (P<.001), while one reported no difference (P=.72). Maternal satisfaction was comparable, with one study favoring digital insertion (P=.011). Meta-analysis findings for other outcome measures suggest no difference between speculum or digital insertion. However, due to substantial heterogeneity, findings for procedural time, time from induction to delivery, and epidural rate should be cautiously interpreted. CONCLUSIONS: Digital insertion for cervical preparation appears associated with reduced pain and higher patient acceptability compared to speculum-based insertion. Additionally, efficacy and safety were comparable, indicating it is a preferable option for clinical use. There was no difference in other procedural, obstetric, or neonatal outcomes, however, more rigorous research employing standardized outcome measures is needed to facilitate a clinically meaningful interpretation.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Digital versus speculum insertion of Foley catheter for labor induction: A systematic review and meta-analysis of randomized controlled trials
    Baradwan, Saeed
    Alshahrani, Majed Saeed
    AlSghan, Rayan
    Sabban, Hussein
    Khadawardi, Khalid
    Alyafi, Mohammad
    Hafedh, Bandr
    Alayed, Nada M.
    Rashed, Zaky Ftouh
    Abdel-Hakam, Faiza Ahmed
    Elshabrawi, Mohamed Nasser
    Abdelhakim, Ahmed Mohamed
    Ahmed, Walaa Elsayed
    JOURNAL OF GYNECOLOGY OBSTETRICS AND HUMAN REPRODUCTION, 2024, 53 (05)
  • [2] Outpatient versus inpatient balloon catheter insertion for labor induction: A systematic review and meta-analysis of randomized controlled trials
    Abdelhakim, Ahmed Mohamed
    Shareef, Mohammad Abrar
    AlAmodi, Abdulhadi A.
    Aboshama, Rehab Abdelhamid
    Fathi, Mohamed
    Abbas, Ahmed M.
    JOURNAL OF GYNECOLOGY OBSTETRICS AND HUMAN REPRODUCTION, 2020, 49 (08)
  • [3] Foley catheter balloon versus prostaglandins for cervical ripening and labor induction: a systematic review and meta-analysis
    Li, Yue
    He, Zhigang
    Song, Liwen
    Zhang, Jiawen
    Wang, Jinbo
    Cheng, Jiajing
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (04): : 7573 - 7584
  • [4] Single versus Double-Balloon Transcervical Catheter for Labor Induction: A Systematic Review and Meta-Analysis
    de los Reyes, Samantha X.
    Sheffield, Jeanne S.
    Eke, Ahizechukwu C.
    AMERICAN JOURNAL OF PERINATOLOGY, 2019, 36 (08) : 790 - 797
  • [5] Increased foley catheter balloon volume for induction of labor: A systematic review and meta-analysis
    Schoen, Corina
    Saccone, Gabriele
    Backley, Sami
    Sandberg, Evelien
    Gu, Ning
    Delaney, Shani
    Berghella, Vincenzo
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2018, 218 (01) : S229 - S229
  • [6] Double-balloon versus single-balloon catheter for cervical ripening and labor induction: A systematic review and meta-analysis
    Yang, Fang
    Huang, Shijin
    Long, Yu
    Huang, Lingling
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2018, 44 (01) : 27 - 34
  • [7] Intracervical balloon catheter for labor induction after rupture of membranes: a systematic review and meta-analysis
    Mackeen, A. Dhanya
    Quinn, Shantel T.
    Movva, Vani C.
    Berghella, Vincenzo
    Ananth, Cande V.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2021, 224 (06) : 624 - 628
  • [8] Double- versus single-balloon catheter for induction of labor: Systematic review and individual participant data meta-analysis
    Peel, Morgan D. D.
    Croll, Doortje M. R.
    Kessler, Jorg
    Haugland, Birte
    Pennell, Craig E. E.
    Dickinson, Jan E. E.
    Salim, Raed
    Zafran, Noah
    Palmer, Kirsten R. R.
    Mol, Ben W. W.
    Li, Wentao
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2023, 102 (11) : 1440 - 1449
  • [9] Induction of Labor Using a Foley Catheter or Misoprostol: A Systematic Review and Meta-analysis
    ten Eikelder, Mieke L. G.
    Mast, Kelly
    van der Velden, Annemarie
    Bloemenkamp, Kitty W. M.
    Mol, Ben W.
    OBSTETRICAL & GYNECOLOGICAL SURVEY, 2016, 71 (10) : 620 - 630
  • [10] Speculum versus digital insertion of Foley catheter for induction of labor in Nulliparas with unripe cervix: a randomized controlled trial
    Chia, Hang Min
    Tan, Peng Chiong
    Tan, Sze Ping
    Hamdan, Mukhri
    Omar, Siti Zawiah
    BMC PREGNANCY AND CHILDBIRTH, 2020, 20 (01)