Contact and Non-Contact Measurements of Chlorophyll-a in Water Based on Laser Spectroscopy

被引:0
|
作者
Dong, Xiuyue [1 ]
Che, Xiaohua [2 ]
Tian, Zhaoshuo [2 ]
机构
[1] Harbin Inst Technol, Sch Marine Sci & Technol, Weihai 264209, Peoples R China
[2] Harbin Inst Technol, Sch Informat Sci & Engn, Weihai 264209, Peoples R China
基金
中国国家自然科学基金;
关键词
Chlorophyll-a; laser induced fluorescence; fluorescence spectroscopy; contact and non-contact; DISSOLVED ORGANIC-MATTER; FLUORESCENCE; LIDAR;
D O I
10.3390/jmse13020293
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Chlorophyll-a fluorescence detection is an important technique for monitoring water quality. In this paper, we proposed an approach that employs the ratio of fluorescence to Raman obtained from contact and non-contact laser-induced fluorescence detection methods as the key for the detection of Chlorophyll-a in water. At first, extracted Chlorophyll-a solutions were prepared, and each sample was tested using two detection methods. The true values of the samples were measured in the laboratory using spectrophotometry. Then, the detection system was calibrated through the linear fitting of Chlorophyll-a and the fluorescence-Raman ratio. The linear correlation coefficients of contact and non-contact detection were 0.9453 and 0.9401, respectively. Finally, we tested the actual water samples in two ways, and compared the test results with the value measured using the national standard method. The root mean square error (RMSE) of contact and non-contact detection was 0.16 and 0.23, respectively. The results show that the two detection methods have high accuracy and sensitivity, and preliminary preparation of samples is not required. Compared with contact detection, the non-contact detection results had higher accuracy and stronger anti-interference, but the maintenance cost was higher because the probe is vulnerable to wear. The advantage of non-contact detection is that it avoids sample contamination and is easy to apply over large areas of water. In the future, it can be used for the real-time monitoring of algal biomass in water by selecting the appropriate detection method according to the requirements of the application.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Non-contact anthropometric measurements in newborn patients
    Burini, Sara
    Marchionni, Paolo
    Scalise, Lorenzo
    Spinsante, Susanna
    Ferretti, Enrica
    Carnielli, Virgilio Paolo
    2020 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2020,
  • [42] Ensuring the accuracy of non-contact temperature measurements
    Rols, Joris
    Electronics World, 2022, 127 (2013): : 22 - 23
  • [43] Rapid Non-Contact Detection of Chemical Warfare Agents by Laser Photoacoustic Spectroscopy
    Fiorani, Luca
    Ciceroni, Claudio
    Giardina, Isabella
    Pollastrone, Fabio
    SENSORS, 2024, 24 (01)
  • [44] Laser-fiberoptic non-contact controlled heating of samples for thermoluminescence measurements
    Gayer, O
    Katzir, A
    JOURNAL OF LUMINESCENCE, 2005, 113 (1-2) : 151 - 155
  • [45] 360 nm Continuous Wave Laser-Based Contact or Non-Contact Laser Interference Nano Lithography
    Yun, Dan Hee
    Shin, Bo Sung
    Park, Jun Han
    Ma, Yong-Won
    Gwak, Cheong Yeol
    You, Dong Bin
    Kim, Byung
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2020, 20 (01) : 128 - 134
  • [46] Non-contact tonometry using laser interferometry
    Drescher, J
    Stork, W
    Hey, S
    Gundlach, A
    Glaser, KDM
    Kreiner, C
    MEDICAL APPLICATIONS OF LASERS IN DERMATOLOGY, CARDIOLOGY, OPHTHALMOLOGY, AND DENTISTRY II, PROCEEDINGS OF, 1999, 3564 : 122 - 130
  • [47] NON-CONTACT LASER INTERFEROMETER SWEEP GAUGE
    BARKMAN, WE
    PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1980, 2 (01): : 9 - 12
  • [48] A non-contact laser probe in industrial measurement
    Li, Y
    Zhang, LX
    Zhang, SL
    Han, YM
    1999 INTERNATIONAL CONFERENCE ON INDUSTRIAL LASERS (IL'99), 1999, 3862 : 306 - 310
  • [49] Non-contact temperature measurement by laser technology
    Huang, Fang
    Liu, Xiangxin
    Han, Junfeng
    Wang, Jing
    Li, Hui
    Wang, Wenjing
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2013, 33 (07): : 642 - 646
  • [50] Water Velocity Measurement using Contact and Non-contact Type Sensor
    Waghmare, Amit
    Naik, A. A.
    2015 COMMUNICATION, CONTROL AND INTELLIGENT SYSTEMS (CCIS), 2015, : 334 - 338