Contact and Non-Contact Measurements of Chlorophyll-a in Water Based on Laser Spectroscopy

被引:0
|
作者
Dong, Xiuyue [1 ]
Che, Xiaohua [2 ]
Tian, Zhaoshuo [2 ]
机构
[1] Harbin Inst Technol, Sch Marine Sci & Technol, Weihai 264209, Peoples R China
[2] Harbin Inst Technol, Sch Informat Sci & Engn, Weihai 264209, Peoples R China
基金
中国国家自然科学基金;
关键词
Chlorophyll-a; laser induced fluorescence; fluorescence spectroscopy; contact and non-contact; DISSOLVED ORGANIC-MATTER; FLUORESCENCE; LIDAR;
D O I
10.3390/jmse13020293
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Chlorophyll-a fluorescence detection is an important technique for monitoring water quality. In this paper, we proposed an approach that employs the ratio of fluorescence to Raman obtained from contact and non-contact laser-induced fluorescence detection methods as the key for the detection of Chlorophyll-a in water. At first, extracted Chlorophyll-a solutions were prepared, and each sample was tested using two detection methods. The true values of the samples were measured in the laboratory using spectrophotometry. Then, the detection system was calibrated through the linear fitting of Chlorophyll-a and the fluorescence-Raman ratio. The linear correlation coefficients of contact and non-contact detection were 0.9453 and 0.9401, respectively. Finally, we tested the actual water samples in two ways, and compared the test results with the value measured using the national standard method. The root mean square error (RMSE) of contact and non-contact detection was 0.16 and 0.23, respectively. The results show that the two detection methods have high accuracy and sensitivity, and preliminary preparation of samples is not required. Compared with contact detection, the non-contact detection results had higher accuracy and stronger anti-interference, but the maintenance cost was higher because the probe is vulnerable to wear. The advantage of non-contact detection is that it avoids sample contamination and is easy to apply over large areas of water. In the future, it can be used for the real-time monitoring of algal biomass in water by selecting the appropriate detection method according to the requirements of the application.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Non-contact detection of explosives by means of a tunable diode laser spectroscopy
    Nadezhdinskii, A. I.
    Ponurovskii, Ya. Ya.
    Stavrovskii, D. B.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 90 (02): : 361 - 364
  • [22] Non-contact detection of explosives by means of a tunable diode laser spectroscopy
    A.I. Nadezhdinskii
    Ya.Ya. Ponurovskii
    D.B. Stavrovskii
    Applied Physics B, 2008, 90 : 361 - 364
  • [23] Non-contact laser spectroscopy for plant discrimination in terrestrial crop spraying
    Sahba, Kaveh
    Askraba, Sreten
    Alameh, Kamal E.
    OPTICS EXPRESS, 2006, 14 (25): : 12485 - 12493
  • [24] Laser heating and detection of bilayer microcantilevers for non-contact thermodynamic measurements
    Burke, Brian G.
    LaVan, David A.
    APPLIED PHYSICS LETTERS, 2013, 102 (02)
  • [25] Non-contact Heart Rate Measurements Based on Skin Detection
    Zhao Ting
    Zhou Zuofeng
    Chen Pengyong
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806
  • [26] Non-contact microprocessor based digital laser scanning micrometer
    Chaudhary, K.P.
    Moitra, Shashi
    Agarwal, A.N.
    IETE Journal of Research, 1994, 40 (04) : 163 - 168
  • [27] A non-contact gear measurement method based on laser vision
    Song L.-M.
    Qin M.-C.
    Li Z.-Y.
    Yang Y.-G.
    Li D.-P.
    Song, L.-M. (lilymay1976@126.com), 1600, Springer Verlag (10): : 237 - 240
  • [28] Non-contact microprocessor based digital laser scanning micrometer
    Chaudhary, KP
    Moitra, S
    Agarwal, AN
    JOURNAL OF THE INSTITUTION OF ELECTRONICS AND TELECOMMUNICATION ENGINEERS, 1994, 40 (04): : 163 - 168
  • [29] Non-contact, laser-based monitoring of physiological activity
    Scalise, L.
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2012, 85 (03) : 312 - 312
  • [30] Electroluminescence Excitation Spectroscopy: A Novel Approach to Non-Contact Quantum Efficiency Measurements
    Davis, Kristopher O.
    Horner, Greg S.
    Gallon, Joshua B.
    Vasilyev, Leonid A.
    Lu, Kyle B.
    Dirriwachter, Antonius B.
    Rigdon, Terry B.
    Schneller, Eric J.
    Ogutman, Kortan
    Ahrenkiel, Richard K.
    2017 IEEE 44TH PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC), 2017, : 3448 - 3451