Application value of real-time shear wave elastography in the diagnosis and efficacy evaluation of venous thrombosis

被引:0
|
作者
Wu, Jing [1 ]
Yang, Xiaoyan [1 ]
Liu, Yun [1 ]
Xi, Fang [1 ]
Lei, Ping [1 ]
机构
[1] First Peoples Hosp Tian Shui, Dept Ultrasound, 105 Jianshe Rd, Tianshui City 741000, Gansu, Peoples R China
关键词
Real-time shear wave elastography; lower-limb deep vein thrombosis; diagnosis; treatment plan;
D O I
10.3233/THC-240386
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Deep vein thrombosis (DVT) of the lower limbs is a venous reflux disorder caused by abnormal coagulation of blood components, primarily characterised by swelling and pain in the lower limbs. Key risk factors include prolonged immobility due to bed rest, pregnancy, postpartum or postoperative states, traumas, malignant tumours and long-term contraceptive use. OBJECTIVE: To investigate the application of real-time shear wave elastography (SWE) in diagnosing lower-limb deep vein thrombosis (DVT). METHODS: A total of 91 patients with DVT were selected and divided into three groups: acute phase (n = 29), subacute phase (n = 30) and chronic phase (n = 32). The Young's modulus of the patients was measured using real-time SWE. The diagnostic efficacy of Young's modulus was evaluated by ROC curves. The hardness differences in Young's modulus across different parts of the same thrombus (head, body and tail) were measured using SWE. RESULTS: Before treatment, significant differences were observed in Young's modulus among patients with DVT (P <0.001). Following anticoagulant therapy, catheter-directed thrombolysis and systemic thrombolysis, significant differences were noted in Young's modulus among patients at the same stage but receiving different treatments (acute phase: P = 0.003; subacute phase: P = 0.014; chronic phase: P = 0.004). Catheter-directed thrombolysis had greater efficacy than anticoagulant therapy. The area under the curve for SWE in staging patients was 0.917, with a sensitivity of 92.36% and specificity of 93.81%. Significant differences in Young's modulus were found between the thrombus head and thrombus body and tail but not between the thrombus body and thrombus tail. CONCLUSION: Measurement of Young's modulus using SWE can serve as an auxiliary means of evaluating staging, predicting pulmonary embolism and selecting treatment in patients with DVT.
引用
收藏
页码:3513 / 3523
页数:11
相关论文
共 50 条
  • [41] The Value of Real-Time Shear Wave Elastography before and after Rehabilitation of Upper Limb Spasm in Stroke Patients
    Liu, Jun
    Pan, Huijuan
    Bao, Yong
    Zhao, Yanna
    Huang, Li
    Zhan, Weiwei
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [42] Real-time shear wave elastography may predict autoimmune thyroid disease
    Mihaela Vlad
    Ioana Golu
    Simona Bota
    Adrian Vlad
    Bogdan Timar
    Romulus Timar
    Ioan Sporea
    Wiener klinische Wochenschrift, 2015, 127 : 330 - 336
  • [43] Real-time shear wave elastography may predict autoimmune thyroid disease
    Vlad, Mihaela
    Golu, Ioana
    Bota, Simona
    Vlad, Adrian
    Timar, Bogdan
    Timar, Romulus
    Sporea, Ioan
    WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 (9-10) : 330 - 336
  • [44] Prostate Cancer: Diagnostic Performance of Real-time Shear-Wave Elastography
    Correas, Jean-Michel
    Tissier, Anne-Marie
    Khairoune, Ahmed
    Vassiliu, Viorel
    Mejean, Arnaud
    Helenon, Olivier
    Memo, Richard
    Barr, Richard G.
    RADIOLOGY, 2015, 275 (01) : 280 - 289
  • [45] Value of ultrasound shear wave elastography in the diagnosis of adenomyosis
    Acar, S.
    Millar, E.
    Mitkova, M.
    Mitkov, V.
    ULTRASOUND, 2016, 24 (04) : 205 - 213
  • [46] Diagnostic role of real-time shear wave elastography on staging of liver fibrosis
    Xue, Yan
    Zhu, Qing
    Chen, Yuanzheng
    Bai, Nan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (08): : 12911 - 12917
  • [47] Determination of Normal Skin Elasticity by Using Real-time Shear Wave Elastography
    Yang, Yujia
    Wang, Liyun
    Yan, Feng
    Xiang, Xi
    Tang, Yuanjiao
    Zhang, Lingyan
    Liu, Jibin
    Qiu, Li
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (11) : 2507 - 2516
  • [48] Real-time ultrasound shear wave elastography using a local phase gradient
    Gonzalez-Mateo, Enrique
    Camarena, Francisco
    Jimenez, Noe
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2025, 260
  • [49] Efficacy of shear wave elastography for the diagnosis of chronic pancreatitis
    Kojima, Hiroyuki
    Sofuni, Atsushi
    Sugimoto, Katsutoshi
    Tsuchiya, Takayoshi
    Ishii, Kentaro
    Tanaka, Reina
    Tonozuka, Ryosuke
    Yamamoto, Kenjiro
    Hirakawa, Noriyuki
    Itoi, Takao
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2023, 30 (03) : 351 - 359
  • [50] Application of real-time elastography in evaluation of hashimoto thyroiditis progression
    Wang, Jianhong
    Wang, Yiying
    Yu, Fengxia
    Fang, Shibao
    Liu, Xuejun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (03): : 6557 - 6562