Current Sources for Electrical Impedance Tomography IMPETOM

被引:0
|
作者
Sanchez, Pablo [1 ,2 ]
David, Marcelo [3 ]
Gonzalez, Mariana [1 ,2 ]
Morales, Isabel [1 ,2 ]
Simini, Franco [1 ,2 ]
机构
[1] Univ Republica, Fac Med, Nucleo Ingn Biomed, Montevideo, Uruguay
[2] Univ Republica, Fac Ingn, Nucleo Ingn Biomed, Montevideo, Uruguay
[3] Jerusalem Coll Technol, Lev Acad Ctr, Dept Elect Engn, Jerusalem, Israel
关键词
Electrical impedance tomography; bandwidth; total harmonic distortion; voltage-controlled current source; step response electrical impedance tomography;
D O I
10.1007/978-3-031-61960-1_23
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Reliable current sources are imperative in Electrical Impedance Tomography (EIT) as it requires signals with minimum distortion and relatively broad bandwidth. In this work four current sources are compared, Howland modified amongst them, to select one for IMPETOM, our clinical EIT system. Bandwidth analysis (0.5 Hz-10 MHz), total harmonic distortion (up to 1.5%) and output current (1 mA to 5 mA) are studied for four current source designs. All configurations gave good results with bandwidths between 0.5 MHz and 3 MHz, driving loads of between 2 k Omega and 12 k Omega with up to 5 mA peak output currents and 1% maximum total harmonic distortion (THD). Among the options, we found the Negative Feedback current source (NFCS) to have the best performance for IMPETOM.
引用
收藏
页码:233 / 248
页数:16
相关论文
共 50 条
  • [21] Common Ground Method of Current Injection in Electrical Impedance Tomography
    Bera, Tushar Kanti
    Nagaraju, J.
    GLOBAL TRENDS IN INFORMATION SYSTEMS AND SOFTWARE APPLICATIONS, PT 2, 2012, 270 : 574 - 587
  • [22] Electrical impedance tomography
    Lobo, Beatriz
    Hermosa, Cecilia
    Abella, Ana
    Gordo, Federico
    ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6 (02)
  • [23] Electrical impedance tomography
    Saulnier, GJ
    Blue, RS
    Newell, JC
    Isaacson, D
    Edic, PM
    IEEE SIGNAL PROCESSING MAGAZINE, 2001, 18 (06) : 31 - 43
  • [24] Electrical impedance tomography
    Cheney, M
    Isaacson, D
    Newell, JC
    SIAM REVIEW, 1999, 41 (01) : 85 - 101
  • [25] Electrical impedance tomography
    Kotre, CJ
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 : S200 - S205
  • [26] Electrical Impedance Tomography
    Hinz, Jose
    CURRENT RESPIRATORY MEDICINE REVIEWS, 2009, 5 (02) : 105 - 109
  • [27] Electrical impedance tomography
    Borcea, L
    INVERSE PROBLEMS, 2002, 18 (06) : R99 - R136
  • [28] Electrical impedance tomography
    Costa, Eduardo L. V.
    Lima, Raul Gonzalez
    Amato, Marcelo B. P.
    CURRENT OPINION IN CRITICAL CARE, 2009, 15 (01) : 18 - 24
  • [29] Bioimpedance tomography (Electrical impedance tomography)
    Bayford, R. H.
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2006, 8 : 63 - 91
  • [30] An 89.3% Current Efficiency, Sub 0.1% THD Current Driver for Electrical Impedance Tomography
    Li, Jiayang
    Jiang, Dai
    Wu, Yu
    Neshatvar, Nazanin
    Bayford, Richard
    Demosthenous, Andreas
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2023, 70 (10) : 3742 - 3746