Development and experimental study of a replaceable double stage coupling beam damper

被引:0
|
作者
Pan, Hengyi [1 ,2 ,5 ]
Wang, Haishen [3 ,4 ]
Wang, Tao [1 ,2 ,5 ]
Pan, Peng [3 ,4 ]
机构
[1] China Earthquake Adm, Key Lab Earthquake Engn & Engn Vibrat, Beijing, Peoples R China
[2] China Earthquake Adm, Inst Engn Mech, Beijing, Peoples R China
[3] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[4] Tsinghua Univ, Dept Civil Engn, Key Lab Civil Engn Safety & Durabil, China Educ Minist, Beijing 100084, Peoples R China
[5] Minist Emergency Management, Key Lab Earthquake Disaster Mitigat, Harbin 150080, Peoples R China
关键词
Metallic damper; Viscoelastic damper; Double stage; Seismic resilience; Quasi-static test; SHEAR WALL STRUCTURES; VISCOELASTIC DAMPERS; SEISMIC DESIGN; FRAME;
D O I
10.1016/j.engstruct.2024.119392
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A double stage coupling beam damper (DSCBD) was proposed and tested in this paper. The DSCBD comprises a viscoelastic damper and a metallic damper connected in series. Deformation of the DSCBD in the first stage was concentrated on the viscoelastic damper, which provided initial stiffness and energy dissipation capacity. With the increase in displacement and the initiation of the second stage, the deformation of the viscoelastic damper was constrained by the limiting mechanism and triggered the deformation concentrating in the metallic damper. These further increased the stiffness and energy dissipation capacity and the DSCBD exhibits the double stage behavior. The DSCBD proposed in this paper can simultaneously satisfy the seismic requirements of the main structure under different levels of seismic excitation, without installing different types of traditional dampers to achieve the same effect. A performance-based design method was proposed. Two full-scale DSCBD specimens were subjected to quasi-static multi-stage cyclic loading tests to investigate the effects of different aspect ratios. The test results showed that DSCBD with an aspect ratio of 3.2 exhibited ideal shear failure mode, and the minimum equivalent viscoelastic damping ratio in the second stage was 22.58 %, while the DSCBD with an aspect ratio of 4.4 exhibited unexpected bending failure mode, and the maximum equivalent viscoelastic damping ratio in the second stage was 19.42%. In addition, the DSCBD with an aspect ratio of 3.2 showed better low-cycle fatigue capacity, whose degradation of bearing and energy dissipation capacities can be controlled within 5% after 30 additional loading cycles. The accuracy and the correction scheme of the design method were verified by the test results.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Experimental and numerical study on a new double-walled tuned liquid damper
    Meshkat Rouhani V.R.
    Zamani Ahar G.
    Saeed Monir H.
    International Journal of Engineering, Transactions B: Applications, 2022, 35 (01):
  • [42] SQUEEZE FILM DAMPER BEARING WITH DOUBLE-ENDED BEAM SPRINGS: PART II EXPERIMENTAL VALIDATION
    Li, Wei
    Braman, Christopher
    Hantz, Brian
    Thorat, Manish
    Pettinato, Brian
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 10A, PT II, 2020,
  • [43] Development and Experimental Validation of a Timber Beam-to-Steel Column Connection with Replaceable U-Shaped Fuses
    Mowafy, Ahmed
    Imanpour, Ali
    Chui, Ying-Hei
    Daneshvar, Hossein
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (11)
  • [44] Experimental study on the seismic performance of new precast concrete beam-column joints with replaceable connection
    Huang, Wei
    Hu, Gaoxing
    Zhang, Jiarui
    STRUCTURES, 2022, 35 : 856 - 872
  • [45] Seismic performance of stiffness enhanced metal coupling beam damper
    Yang, Wei-Song
    Zhang, An
    Xu, Wei-Xiao
    Li, Hai-Sheng
    Du, Ke
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2024, 54 (09): : 2469 - 2483
  • [46] Dynamic experimental and numerical study of double beam-column joints in modern traditional-style steel buildings with viscous damper
    Wu, Zhanjing
    Xue, Jianyang
    Ke, Xiaojun
    Sui, Yan
    Dong, Jinshuang
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (01):
  • [47] Suppression control of positioning noise for dual stage with coupling damper
    Zhang, Shan
    Wang, Lei
    UPB Scientific Bulletin, Series D: Mechanical Engineering, 2015, 77 (02): : 109 - 120
  • [48] Experimental and numerical study on hysteresis behaviour of a novel dual-stage friction damper
    Yang, Yong
    Xue, Jianyang
    Liu, Rui
    STRUCTURES, 2024, 70
  • [49] Experimental study of plate-buckling type earthquake-resilient prefabricated steel beam-column joints with replaceable double flange cover plates
    Jiang, Zi-Qin
    Yan, Tian
    Zhang, Ai-Lin
    Yang, Xiao-Feng
    Yu, Cheng
    Li, Ran
    STRUCTURES, 2023, 50 : 1100 - 1113
  • [50] Dynamic principle analysis of reinforced concrete replaceable coupling beam energy dissipation structure
    Wang, Mingzhen
    Sun, Baitao
    Chen, Hongfu
    Gao, Lin
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2024, 31 (28) : 10687 - 10694