Development and experimental study of a replaceable double stage coupling beam damper

被引:0
|
作者
Pan, Hengyi [1 ,2 ,5 ]
Wang, Haishen [3 ,4 ]
Wang, Tao [1 ,2 ,5 ]
Pan, Peng [3 ,4 ]
机构
[1] China Earthquake Adm, Key Lab Earthquake Engn & Engn Vibrat, Beijing, Peoples R China
[2] China Earthquake Adm, Inst Engn Mech, Beijing, Peoples R China
[3] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[4] Tsinghua Univ, Dept Civil Engn, Key Lab Civil Engn Safety & Durabil, China Educ Minist, Beijing 100084, Peoples R China
[5] Minist Emergency Management, Key Lab Earthquake Disaster Mitigat, Harbin 150080, Peoples R China
关键词
Metallic damper; Viscoelastic damper; Double stage; Seismic resilience; Quasi-static test; SHEAR WALL STRUCTURES; VISCOELASTIC DAMPERS; SEISMIC DESIGN; FRAME;
D O I
10.1016/j.engstruct.2024.119392
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A double stage coupling beam damper (DSCBD) was proposed and tested in this paper. The DSCBD comprises a viscoelastic damper and a metallic damper connected in series. Deformation of the DSCBD in the first stage was concentrated on the viscoelastic damper, which provided initial stiffness and energy dissipation capacity. With the increase in displacement and the initiation of the second stage, the deformation of the viscoelastic damper was constrained by the limiting mechanism and triggered the deformation concentrating in the metallic damper. These further increased the stiffness and energy dissipation capacity and the DSCBD exhibits the double stage behavior. The DSCBD proposed in this paper can simultaneously satisfy the seismic requirements of the main structure under different levels of seismic excitation, without installing different types of traditional dampers to achieve the same effect. A performance-based design method was proposed. Two full-scale DSCBD specimens were subjected to quasi-static multi-stage cyclic loading tests to investigate the effects of different aspect ratios. The test results showed that DSCBD with an aspect ratio of 3.2 exhibited ideal shear failure mode, and the minimum equivalent viscoelastic damping ratio in the second stage was 22.58 %, while the DSCBD with an aspect ratio of 4.4 exhibited unexpected bending failure mode, and the maximum equivalent viscoelastic damping ratio in the second stage was 19.42%. In addition, the DSCBD with an aspect ratio of 3.2 showed better low-cycle fatigue capacity, whose degradation of bearing and energy dissipation capacities can be controlled within 5% after 30 additional loading cycles. The accuracy and the correction scheme of the design method were verified by the test results.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Development of a double-stage-yield dissipative beam-to-column joint: Experimental study and application for structural response control
    Yang, Cantian
    Xie, Linlin
    Li, Aiqun
    Wang, Xinyu
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 171
  • [32] SEISMIC MITIGATION EFFICIENCY STUDY OF THE COUPLING BEAM DAMPER IN THE SHEAR WALL STRUCTURE
    Huang, Xin
    CIVIL ENGINEERING JOURNAL-STAVEBNI OBZOR, 2021, 30 (01): : 17 - 29
  • [33] Seismic performance of subassemblies with composite wall and replaceable steel coupling beam
    Liu, Yang
    Chen, Hai
    Guo, Zi-Xiong
    Hu, Hong-Song
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2020, 19 (02) : 123 - 137
  • [34] Large-scale testing of a replaceable "Fuse" steel coupling beam
    Fortney, Patrick J.
    Shahrooz, Bahrarn M.
    Rassati, Gian A.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2007, 133 (12): : 1801 - 1807
  • [35] Experimental and numerical investigations of replaceable moment-resisting viscoelastic damper for steel frames
    Shu, Zhan
    Ning, Bo
    Li, Shuang
    Li, Zheng
    Gan, Zhaozhuo
    Xie, Yazhou
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 170 (170)
  • [36] An experimental study on eccentrically braced beam-through steel frames with replaceable shear links
    Yao, Zucheng
    Wang, Wei
    Fang, Cheng
    Zhang, Ziyao
    ENGINEERING STRUCTURES, 2020, 206
  • [37] Introducing and numerical study of an innovative rotational damper with replaceable hourglass steel pins
    Garmeh, Vandad
    Akbarpour, Abbas
    Adibramezani, Mohammadreza
    Kashani, Ata Hojat
    Adibi, Mahdi
    STRUCTURES, 2021, 33 : 2019 - 2035
  • [38] Design of an Innovative Eddy Current Replaceable Coupling Beam and Its Numerical Analysis
    Gong N.
    Li P.
    He X.
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2022, 50 (07): : 25 - 34
  • [39] Automated locating of replaceable coupling steel beam using terrestrial laser scanning
    Zhou, Xuhong
    Liu, Jiepeng
    Cheng, Guozhong
    Li, Dongsheng
    Chen, Y. Frank
    AUTOMATION IN CONSTRUCTION, 2021, 122
  • [40] Experimental and Numerical Study on a New Double-Walled Tuned Liquid Damper
    Rouhani, V. R. Meshkat
    Ahar, G. Zamani
    Monir, H. Saeed
    INTERNATIONAL JOURNAL OF ENGINEERING, 2022, 35 (01):