Flow-induced corrosion of brass flowmeters used for drinking water

被引:0
|
作者
Boncz, Luca Blanka [1 ,2 ]
Holmegaard, Lotte [2 ]
Sorensen, Jens Lykke [2 ]
Hald, John [1 ]
Jellesen, Morten S. [1 ]
机构
[1] Tech Univ Denmark, Dept Civil & Mech Engn, Sect Mat & Surface Engn, Lyngby, Denmark
[2] Kamstrup AS, Skanderborg, Denmark
关键词
Brass; Flow-induced corrosion; Erosion corrosion; Drinking water; Computer fluid dynamics; DEZINCIFICATION; EROSION;
D O I
10.1016/j.engfailanal.2025.109394
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Traditionally, water supply components were made of dezincification-resistant brass alloys due to their relatively low cost, good forging properties, and good machinability. However, due to recent legislation on the restrictions of lead and nickel, increased use of disinfection, and a more diverse range of flow conditions, corrosion failures have become more prevalent. This work describes the failure investigations of two domestic water flowmeters made of dezincification-resistant brass type CW511L, with a difference in internal diameter. The underlying cause of failure is determined by visual inspection, microstructural analysis with scanning electron microscopy, energydispersive X-ray spectroscopy, and corrosion product identification using X-ray diffraction. The scales formed at less degraded regions were identified as copper-enriched corrosion products mainly consisting of metallic elements, oxygen, and chloride, with most of the scale formation being malachite. Depletion of protective scales was seen in regions with high flow, resulting in flow-induced corrosion and high material losses. Computer fluid dynamics simulations confirm that specific regions were exposed to high flow rates, resulting in failure.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Brass corrosion inhibitors in simulated atmospheric water
    Liang, C.
    Gao, G.
    CORROSION, 2007, 63 (11) : 987 - 996
  • [42] Coupling response of flow-induced oscillating cylinder with a pair of flow-induced rotating impellers
    Zhu, Hongjun
    Chu, Xin
    Yan, Zhiyin
    Gao, Yun
    PHYSICS OF FLUIDS, 2021, 33 (08)
  • [43] Corrosion in a drinking water pipeline
    不详
    MATERIALS PERFORMANCE, 2007, 46 (05) : 52 - +
  • [44] FLOW-INDUCED VIBRATION ANALYSIS OF A WATER INJECTION SYSTEM AT ELEVATED FLOW RATES OF AN FPSO
    Diez, Nestor Gonzalez
    Pontaza, Juan P.
    Awe, Oluwaseun M.
    van Beek, Pieter
    Tumer, Can
    PROCEEDINGS OF THE ASME 38TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2019, VOL 5A, 2019,
  • [45] Pressure Fluctuation and Flow-Induced Noise of the Fin and Rudder in a Water Tunnel
    Qu, Duo
    Li, Yanfei
    Li, Ruibiao
    Chen, Yunhui
    Zhang, Yongou
    APPLIED SCIENCES-BASEL, 2024, 14 (11):
  • [46] Aspects of flow-induced vibration
    Leonard, A
    Roshko, A
    JOURNAL OF FLUIDS AND STRUCTURES, 2001, 15 (3-4) : 415 - 425
  • [47] Flow-induced structure in polymers
    1600, ACS, Washington, DC, USA (117):
  • [48] Polymeric microstructure arrays consequence of Marangoni flow-induced water droplets
    Cai, Y.
    Newby, B. -M. Zhang
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2010, 100 (04): : 1221 - 1229
  • [49] Polymeric microstructure arrays consequence of Marangoni flow-induced water droplets
    Y. Cai
    B.-m. Zhang Newby
    Applied Physics A, 2010, 100 : 1221 - 1229
  • [50] Improvement of corrosion resistance of materials used in drinking water systems by laser surface melting
    Chan, WM
    Cheng, FT
    Chow, WK
    Man, HC
    20TH ICALEO 2001, VOLS 92 & 93, CONGRESS PROCEEDINGS, 2001, : 69 - 78