Benefits of Usability Evaluation in the Development Process of Diabetes Technologies Using the Example of a Continuous Glucose Monitoring System Prototype

被引:0
|
作者
Beltzer, Anne [1 ]
Koelle, Julia [1 ]
Miro, Marta Gil [1 ]
Pleus, Stefan [1 ]
Krauss, Collin [1 ]
Haug, Cornelia [1 ]
Safary, Elvis [2 ]
Vetter, Beatrice [2 ]
Freckmann, Guido [1 ]
机构
[1] Univ Ulm, Inst Diabet Technol Forsch & Entwicklungsgesell mb, Lise Meitner Str 8-2, D-89081 Ulm, Germany
[2] FIND, Geneva, Switzerland
关键词
continuous glucose monitoring; diabetes technology; human factors; SUS score; usability; use error; INSULIN INJECTIONS; ADULTS; TYPE-1;
D O I
10.1177/19322968241238146
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Usability engineering analyzes the interaction between the intended users and a device. Its implementation is mandatory for manufacturers to obtain regulatory approval for the European market. The aim of this evaluation was assessing the role of usability testing in the development process. For this purpose, a continuous glucose monitoring (CGM) device under development was investigated to determine whether it could be used safely and effectively by the intended users.Methods: Conduct of the usability testing was based on the international standard IEC 62366-1. Medical device use of CGM-experienced and non-experienced users (n = 15 each) was observed without initial training in use scenarios containing 18 tasks. The success rate of task completion was determined and the System Usability Scale (SUS) score was calculated from a questionnaire. A prototype of the FiberSense CGM System (EyeSense GmbH, Gro ss ostheim, Germany), comprising of a single-use sensor and a reusable detector, was investigated.Results: Most use errors made by both user groups were related to ease of handling of the reusable detectors. The SUS scores achieved in this study were below the pre-defined SUS score acceptance criterion of >= 68. The most frequently mentioned reason for use errors was an incomprehensible and non-chronological instructions for use (IFU).Conclusions: The evaluation provides valuable insights on how to improve usability of the prototype device and demonstrates the value of conducting structured usability testing prior to product finalization. The results reflected areas for improvement of the user interface, mainly by restructuring the IFU, provision of an additional leaflet, and device training prior to use.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Evaluation of the performance and usability of a novel continuous glucose monitoring system
    Yan, Li
    Li, Qiang
    Guan, Qingbo
    Han, Mingsong
    Zhao, Yu
    Fang, Junfei
    Zhao, Jiajun
    INTERNATIONAL JOURNAL OF DIABETES IN DEVELOPING COUNTRIES, 2023, 43 (04) : 551 - 558
  • [2] Evaluation of the performance and usability of a novel continuous glucose monitoring system
    Li Yan
    Qiang Li
    Qingbo Guan
    Mingsong Han
    Yu Zhao
    Junfei Fang
    Jiajun Zhao
    International Journal of Diabetes in Developing Countries, 2023, 43 : 551 - 558
  • [3] The usability evaluation indicators for IS prototype development process
    Luo, Mei
    Jiang, Jianhong
    PROCEEDINGS OF THE 1ST INTERNATIONAL SYMPOSIUM ON SOCIAL SCIENCE (ISSS-15), 2015, 24 : 237 - 242
  • [4] The Benefits of Using Continuous Glucose Monitoring to Diagnose Type 1 Diabetes
    Ayers, Alessandra T.
    Ho, Cindy N.
    Wong, Jenise C.
    Kerr, David
    Mader, Julia K.
    Klonoff, David C.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024,
  • [5] Evaluation of a continuous glucose monitoring system in cats with diabetes mellitus
    Ristic, JME
    Herrtage, ME
    Walti-Lauger, SMM
    Slater, LA
    Church, DB
    Davison, LJ
    Catchpole, B
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2005, 7 (03) : 153 - 162
  • [6] Benefits and limitations of continuous glucose monitoring in type 1 diabetes
    Stone, Jenine Y.
    Bailey, Timothy S.
    EXPERT REVIEW OF ENDOCRINOLOGY & METABOLISM, 2020, 15 (01) : 41 - 49
  • [7] USABILITY, SAFETY, AND BENEFITS OF MULTIPLE SENSOR USE OF A LONG-TERM IMPLANTABLE CONTINUOUS GLUCOSE MONITORING SYSTEM
    Chen, X. O.
    Addaguduru, S.
    Mdingi, C.
    Rastogi, R.
    DeHennis, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A42 - A42
  • [8] A predictive tool for the self-management of diabetes (Librae): evaluation using a continuous glucose monitoring system
    Franklin, VL
    Wilson, AW
    Butler, RA
    Greene, SA
    DIABETIC MEDICINE, 2006, 23 (01) : 21 - 25
  • [9] Flash glucose monitoring system in gestational diabetes: a study of accuracy and usability
    Sara Campos Lopes
    Ana Isabel Brito
    Mariana Barbosa
    Ana Catarina Matos
    Maria Lopes Pereira
    Ana Margarida Monteiro
    Vera Fernandes
    Hormones, 2023, 22 (4) : 703 - 713
  • [10] Continuous Glucose Monitoring Sensors for Diabetes Management: A Review of Technologies and Applications
    Cappon, Giacomo
    Vettoretti, Martina
    Sparacino, Giovanni
    Facchinetti, Andrea