Benefits of Usability Evaluation in the Development Process of Diabetes Technologies Using the Example of a Continuous Glucose Monitoring System Prototype

被引:0
|
作者
Beltzer, Anne [1 ]
Koelle, Julia [1 ]
Miro, Marta Gil [1 ]
Pleus, Stefan [1 ]
Krauss, Collin [1 ]
Haug, Cornelia [1 ]
Safary, Elvis [2 ]
Vetter, Beatrice [2 ]
Freckmann, Guido [1 ]
机构
[1] Univ Ulm, Inst Diabet Technol Forsch & Entwicklungsgesell mb, Lise Meitner Str 8-2, D-89081 Ulm, Germany
[2] FIND, Geneva, Switzerland
关键词
continuous glucose monitoring; diabetes technology; human factors; SUS score; usability; use error; INSULIN INJECTIONS; ADULTS; TYPE-1;
D O I
10.1177/19322968241238146
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Usability engineering analyzes the interaction between the intended users and a device. Its implementation is mandatory for manufacturers to obtain regulatory approval for the European market. The aim of this evaluation was assessing the role of usability testing in the development process. For this purpose, a continuous glucose monitoring (CGM) device under development was investigated to determine whether it could be used safely and effectively by the intended users.Methods: Conduct of the usability testing was based on the international standard IEC 62366-1. Medical device use of CGM-experienced and non-experienced users (n = 15 each) was observed without initial training in use scenarios containing 18 tasks. The success rate of task completion was determined and the System Usability Scale (SUS) score was calculated from a questionnaire. A prototype of the FiberSense CGM System (EyeSense GmbH, Gro ss ostheim, Germany), comprising of a single-use sensor and a reusable detector, was investigated.Results: Most use errors made by both user groups were related to ease of handling of the reusable detectors. The SUS scores achieved in this study were below the pre-defined SUS score acceptance criterion of >= 68. The most frequently mentioned reason for use errors was an incomprehensible and non-chronological instructions for use (IFU).Conclusions: The evaluation provides valuable insights on how to improve usability of the prototype device and demonstrates the value of conducting structured usability testing prior to product finalization. The results reflected areas for improvement of the user interface, mainly by restructuring the IFU, provision of an additional leaflet, and device training prior to use.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Continuous glucose monitoring in pregnant women with Type 1 diabetes: benefits for mothers, using pumps or pens, and their babies
    Feig, D. S.
    Murphy, H. R.
    DIABETIC MEDICINE, 2018, 35 (04) : 430 - 435
  • [32] Pregnancy outcomes in people with diabetes using continuous glucose monitoring
    Bitar, Ghamar
    Cornthwaite, John
    Cornthwaite, Joy A. Ashby
    Nazeer, Sarah
    Ghafir, Danna
    Sadek, Sandra
    Ghorayeb, Tala
    Daye, Nahla
    Chauhan, Suneet P.
    Sibai, Baha M.
    Bartal, Michal Fishel
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (01) : S312 - S313
  • [33] Evaluation of Glucose Response to 3 Types of Insulin Using a Continuous Glucose Monitoring System in Healthy Alpacas
    Byers, S. R.
    Beemer, O. M.
    Lear, A. S.
    Callan, R. J.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2014, 28 (05) : 1613 - 1620
  • [34] Benefits and limitations of hypo/hyperglycemic alarms associated with continuous glucose monitoring in individuals with diabetes
    Oriot, Philippe
    Kurz, Noemie Klipper dit
    Ponchon, Michel
    Weber, Eric
    Colin, Ides. M.
    Philips, Jean Christophe
    DIABETES EPIDEMIOLOGY AND MANAGEMENT, 2023, 9
  • [35] The challenging situation of diabetes management in peritoneal dialysis patients: benefits of continuous glucose monitoring
    Gourbesville, Claire
    Joubert, Michael
    CORRESPONDANCES EN METABOLISMES HORMONES DIABETES ET NUTRITION, 2019, 23 (02): : 42 - 45
  • [36] The Benefits of Utilizing Continuous Glucose Monitoring of Diabetes Mellitus in Primary Care: A Systematic Review
    Kieu, Alexander
    King, Jeffrey
    Govender, Romona Devi
    Ostlundh, Linda
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (03): : 762 - 774
  • [37] Characteristics of type 1 diabetes patients using continuous glucose monitoring systems and development of retinopathy
    Khouri, Christopher Albert
    Ooms, Ashley
    Thangmathesvaran, Loka
    Khouri, Peter
    Szirth, Ben
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [38] Evaluation of Continuous Glucose Monitoring (CGM) On Gestational Diabetes Mellitus In China
    Ding, Guifeng
    Liang, Ping
    Peng, Yan
    Pang, Yunxia
    Zheng, Yongzhen
    DIABETES, 2012, 61 : A588 - A588
  • [39] Evaluation of sensor sites for continuous glucose monitoring in cats with diabetes mellitus
    Hafner, Michaela
    Lutz, Thomas A.
    Reusch, Claudia E.
    Zini, Eric
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2013, 15 (02) : 117 - 123
  • [40] Diabetes Monitoring System Using Mobile Computing Technologies
    Bin-Sabbar, Mashael Saud
    Al-Rodhaan, Mznah Abdullah
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2013, 4 (02) : 23 - 31