Evaluation of the performance and usability of a novel continuous glucose monitoring system

被引:2
|
作者
Yan, Li [1 ]
Li, Qiang [2 ]
Guan, Qingbo [3 ]
Han, Mingsong [4 ]
Zhao, Yu [4 ]
Fang, Junfei [4 ]
Zhao, Jiajun [3 ]
机构
[1] Sun Yat Sen Univ, Sun Yat Sen Mem Hosp, Dept Endocrinol & Metab, Guangzhou, Peoples R China
[2] Shenzhen Univ, Gen Hosp, Dept Endocrinol & Metab, Shenzhen, Peoples R China
[3] Shandong Prov Hosp, Dept Endocrinol & Metab, 324 Jing Wu Rd, Jinan 250021, Shandong, Peoples R China
[4] Shenzhen Sibinoincs Technol Co LTD, Shenzhen, Peoples R China
关键词
Blood glucose monitoring; Sensor accuracy; Performance; Usability; Continuous glucose monitoring; FREESTYLE LIBRE; BLOOD-GLUCOSE; CARE; CONSENSUS;
D O I
10.1007/s13410-022-01112-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Continuous glucose monitoring (CGM) can help manage diabetes mellitus (DM) and prevent hypoglycemia. This study aimed to evaluate the performance and usability of a novel SiJoy GS1 CGM system. Methods This multicenter trial enrolled participants with DM. Based on the comparison of glucose values measured by SiJoy GS1 CGM and venous blood glucose test, the 20/20% consistency and mean absolute relative difference (MARD%) were calculated, as well as Clarke and consensus error grid analysis. Product usability was evaluated by questionnaire completed by participants. Any occurrence of adverse events (AE) was documented. Results Seventy participants were included in the study. The mean age of participants was 41.5 +/- 13.2 years, among which 29 (42.0%) were male, with the DM course of 8.6 +/- 7.5 years. A total of 39 (56.5%) of them had type 1 DM, 24 (34.8%) had type 2 DM, and 6 (8.7%) were others for DM. The 20/20% consistency achieved 91.82%, which was higher than the target 65%. The percentage of A + B zones of Clarke and consensus error grid was 99.22% and 99.90%, respectively. The MARD value was 8.83% +/- 4.03%. The mean score of usability questionnaire was 86.59 +/- 5.17 out of 90. AE were observed in only one participant (mild fever), and no severe AEs occurred. Conclusions The SiJoy GS1 CGM system achieved satisfactory performance and usability. No severe AEs occurred and mild AE was reported in only one case.
引用
收藏
页码:551 / 558
页数:8
相关论文
共 50 条
  • [1] Evaluation of the performance and usability of a novel continuous glucose monitoring system
    Li Yan
    Qiang Li
    Qingbo Guan
    Mingsong Han
    Yu Zhao
    Junfei Fang
    Jiajun Zhao
    [J]. International Journal of Diabetes in Developing Countries, 2023, 43 : 551 - 558
  • [2] Safety and performance evaluation of a novel continuous glucose monitoring system: Lumee Glucose
    Nguyen, C.
    Tran, N. Q.
    Ma, P. T.
    Nguyen, H. T.
    Gamsey, S.
    Lepak, C.
    Cereceres, S.
    Rebrin, K.
    [J]. DIABETOLOGIA, 2021, 64 (SUPPL 1) : 285 - 285
  • [3] Evaluation of a Novel Glucose Area Under the Curve (AUC) Monitoring System: Comparison with the AUC by Continuous Glucose Monitoring
    Ugi, Satoshi
    Maegawa, Hiroshi
    Morino, Katsutaro
    Nishio, Yoshihiko
    Sato, Toshiyuki
    Okada, Seiki
    Kikkawa, Yasuo
    Watanabe, Toshihiro
    Nakajima, Hiromu
    Kashiwagi, Atsunori
    [J]. DIABETES & METABOLISM JOURNAL, 2016, 40 (04) : 326 - 333
  • [4] The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
    Bailey, Timothy
    Bode, Bruce W.
    Christiansen, Mark P.
    Klaff, Leslie J.
    Alva, Shridhara
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) : 787 - 794
  • [5] Evaluation of a continuous glucose monitoring system in diabetic dogs
    Davison, LJ
    Slater, LA
    Herrtage, ME
    Church, DB
    Judge, S
    Ristic, JME
    Catchpole, B
    [J]. JOURNAL OF SMALL ANIMAL PRACTICE, 2003, 44 (10) : 435 - 442
  • [6] Evaluation of a continuous glucose monitoring system in neonatal foals
    Wong, David
    Malik, Caitlin
    Dembek, Katarzyna
    Estell, Krista
    Marchitello, Megan
    Wilson, Katie
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (04) : 1995 - 2001
  • [7] Performance Evaluation of a Continuous Glucose Monitoring System Under Conditions Similar to Daily Life
    Pleus, Stefan
    Haug, Cornelia
    Link, Manuela
    Zschornack, Eva
    Freckmann, Guido
    [J]. DIABETES, 2013, 62 : A225 - A226
  • [8] Assessing Glucose Trend Accuracy with a Novel Continuous Glucose Monitoring System
    Johnson, Terri
    Zhang, Xiaohe
    Balo, Andrew
    [J]. DIABETES, 2018, 67
  • [9] Performance evaluation of the Glunovo® continuous blood glucose monitoring system in Chinese participants with diabetes
    Meng, R.
    Zhu, D.
    [J]. DIABETOLOGIA, 2021, 64 (SUPPL 1) : 285 - 286
  • [10] Performance of a Novel Continuous Glucose Monitoring Device in People With Diabetes
    Mader, Julia K.
    Waldenmaier, Delia
    Mueller-Hoffmann, Wiebke
    Mueller, Katrin
    Angstmann, Michael
    Vogt, Gerhard
    Rieger, Cosima C.
    Eichenlaub, Manuel
    Forst, Thomas
    Freckmann, Guido
    [J]. JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024,