Diagnostic Accuracy of 1H-MRS Using PRESS and MEGA-PRESS Techniques in the Preoperative Grading of Patients With Gliomas

被引:0
|
作者
Brun-Vergara, Maria L. [1 ]
Melkus, Gerd [1 ,2 ]
Chakraborty, Santanu [1 ]
Zakhari, Nader [1 ]
Torres, Carlos [1 ]
Alkherayf, Fahad [3 ]
Ghantous, Leya [4 ]
Thornhill, Rebecca [1 ]
Woulfe, John [5 ]
Jansen, Gerard H. [5 ]
Nguyen, Thanh B. [1 ]
机构
[1] Univ Ottawa, Ottawa Hosp, Dept Radiol Radiat Oncol & Med Phys, Ottawa, ON, Canada
[2] Carleton Univ, Dept Phys, Ottawa, ON, Canada
[3] Univ Ottawa, Ottawa Hosp, Div Neurosurg, Ottawa, ON, Canada
[4] Univ Sherbrooke, Fac Med, Sherbrooke, PQ, Canada
[5] Univ Ottawa, Dept Pathol & Lab Med, Eastern Ontario Reg Labs Assoc, Ottawa, ON, Canada
关键词
metabolites; isocitrate dehydrogenase; MR spectroscopy; MEGA-PRESS; gliomas; MAGNETIC-RESONANCE-SPECTROSCOPY; MR SPECTROSCOPY; TUMORS; BRAIN;
D O I
10.1002/jmri.29690
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundEdited MRS technique such as MEshcher-GArwood Point RESolved Spectroscopy (MEGA-PRESS) can determine isocitrate dehydrogenase mutation (IDH) mutation status in patients with gliomas but its accuracy in assessing glioma grade has not yet been formally evaluated. PurposeTo evaluate the diagnostic accuracy of metabolites such as lactate obtained from the PRESS and MEGA-PRESS sequences in the preoperative grading of glioma. To assess the prognostic value of those metabolite ratios in the overall survival of patients with gliomas. Study TypeProspective. SubjectsSixty-nine subjects with gliomas (16 grade 2, 21 grade 3, and 32 grade 4). Mean age was 50.5 +/- 16.7 years; 38 were male and 31 were female. Field Strength/Sequence3 T/MEGA-PRESS, PRESS. AssessmentSingle voxel PRESS and MEGA-PRESS spectra were obtained from tumors in patients undergoing preoperative MRI. Several tumor metabolites were measured from the PRESS, MEGA-PRESS edit-off, and difference spectra using LCModel (Linear Combination of Model Spectra) software. Diagnosis and glioma grading was done using the World Health Organization (WHO) 2016 classification. Overall survival was assessed. Statistical TestsDiagnostic accuracy was measured using receiver-operating characteristic (ROC) curve. Univariate and multivariate Cox proportional hazards modeling was used for the assessment of prognostic factors for time to death. ResultsIn the differentiation between low- vs. high-grade gliomas, tCr/tCho ratios obtained from PRESS and MEGA-PRESS sequences had similar accuracies (area under the ROC curves [AUCs] = 0.71) while Lac/NAA from PRESS had a lower accuracy (AUC = 0.65). The presence of a detectable 2-hydroxyglutarate peak on the difference spectrum was a favorable prognostic factor in univariate analysis (hazard ratio = 0.25, 95% confidence interval: 0.08-0.83). No other metabolite was found to be a significant prognostic factor in univariate and multivariate analyses. Data ConclusionEdited MRS can be used to detect metabolites which can help in the preoperative grading of gliomas and in determination of the overall survival. A separate PRESS acquisition is needed for lactate quantification. Plain Language SummaryGliomas are brain tumors that vary in severity. This study explored the use of two advanced MR spectroscopy techniques (PRESS and MEGA-PRESS) in detecting tumor metabolites. The authors found that both techniques' choline/creatine ratio showed moderate accuracy in identifying high-grade gliomas. Lactate was better revealed with the PRESS technique and was associated with high-grade gliomas. They confirmed that the MEGA-PRESS technique allowed additional detection of 2-hydroxyglutarate in IDH-mutant gliomas, which was linked to better survival. These findings emphasize that advanced MR spectroscopy can extract metabolic information time-efficiently, which can be used to improve the preoperative diagnosis of patients with gliomas. Level of Evidence1 Technical EfficacyStage 2
引用
收藏
页数:9
相关论文
共 29 条
  • [21] Brain metabolism in patients after ECMO measured using proton MR spectroscopy (1H-MRS)
    Roelants-van Rijn, AM
    van der Grond, J
    de Vries, LS
    Groenendaal, F
    PEDIATRIC RESEARCH, 2000, 47 (04) : 321A - 321A
  • [22] Diagnostic Accuracy of Dynamic Contrast-Enhanced MR Imaging Using a Phase-Derived Vascular Input Function in the Preoperative Grading of Gliomas
    Nguyen, T. B.
    Cron, G. O.
    Mercier, J. F.
    Foottit, C.
    Torres, C. H.
    Chakraborty, S.
    Woulfe, J.
    Jansen, G. H.
    Caudrelier, J. M.
    Sinclair, J.
    Hogan, M. J.
    Thornhill, R. E.
    Cameron, I. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (08) : 1539 - 1545
  • [23] Imaging of nerve injury in neonatal acute bilirubin encephalopathy using 1H-MRS and Glu-CEST techniques
    Lin, Qihuan
    Chen, Lanmei
    Zheng, Hongyi
    Tan, Hui
    Zhang, Gengbiao
    Zheng, Wenbin
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [24] Lower glutamate levels in rostral anterior cingulate of chronic cocaine users - A 1H-MRS study using TE-averaged PRESS at 3 T with an optimized quantification strategy
    Yang, Shaolin
    Salmeron, Betty Jo
    Ross, Thomas J.
    Xi, Zheng-Xiong
    Stein, Elliot A.
    Yang, Yihong
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2009, 174 (03) : 171 - 176
  • [25] Study on Dorsolateral Prefrontal Cortex Neurochemical Metabolite Levels of Patients with Major Depression Using 1H-MRS Technique
    Sendur, Ibrahim
    Oguzhanoglu, Nalan Kalkan
    Varma, Gulfizar Sozeri
    TURK PSIKIYATRI DERGISI, 2020, 31 (02) : 75 - 83
  • [26] 兔肝VX2瘤活体二维多体素1H-MRS成像STEAM和PRESS序列的比较
    颜荣华
    肖恩华
    临床放射学杂志, 2008, (02) : 273 - 277
  • [27] 1H MRS phantom studies of BNCT 10B-carrier, BPA-F using STEAM and PRESS MRS sequences:: Detection limit and quantification
    Timonen, M
    Kangasmaki, A
    Savolainen, S
    Heikkinen, S
    SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 2004, 18 (02): : 133 - 142
  • [28] Reliability of 7T 1H-MRS Measured Human Prefrontal Cortex Glutamate, Glutamine, and Glutathione Signals Using an Adapted Echo Time Optimized PRESS Sequence: A Between- and Within-Sessions Investigation
    Lally, Niall
    An, Li
    Banerjee, Dipavo
    Niciu, Mark J.
    Luckenbaugh, David A.
    Richards, Erica M.
    Roiser, Jonathan P.
    Shen, Jun
    Zarate, Carlos A., Jr.
    Nugent, Allison C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) : 88 - 98
  • [29] Differentiation of High-Grade and Low-Grade Gliomas Using Pattern Analysis of Long-Echo Single-Voxel Proton Magnetic Resonance Spectroscopy (1H-MRS)
    Chernov, M. F.
    Ono, Y.
    Muragaki, Y.
    Kubo, O.
    Nakamura, R.
    Iseki, H.
    Hori, T.
    Takakura, K.
    NEURORADIOLOGY JOURNAL, 2008, 21 (03): : 338 - 349