Diagnostic Accuracy of Dynamic Contrast-Enhanced MR Imaging Using a Phase-Derived Vascular Input Function in the Preoperative Grading of Gliomas

被引:33
|
作者
Nguyen, T. B. [1 ]
Cron, G. O. [1 ]
Mercier, J. F. [1 ]
Foottit, C. [2 ]
Torres, C. H. [1 ]
Chakraborty, S. [1 ]
Woulfe, J. [3 ]
Jansen, G. H. [3 ]
Caudrelier, J. M. [1 ]
Sinclair, J. [4 ]
Hogan, M. J. [5 ]
Thornhill, R. E. [1 ]
Cameron, I. G. [1 ,2 ]
机构
[1] Univ Ottawa, Ottawa Hosp, Dept Radiol, Ottawa, ON K1Y 4E9, Canada
[2] Univ Ottawa, Ottawa Hosp, Dept Med Phys, Ottawa, ON K1Y 4E9, Canada
[3] Univ Ottawa, Ottawa Hosp, Dept Pathol, Ottawa, ON K1Y 4E9, Canada
[4] Univ Ottawa, Ottawa Hosp, Dept Surg, Div Neurosurg, Ottawa, ON K1Y 4E9, Canada
[5] Univ Ottawa, Ottawa Hosp, Dept Med, Div Neurol, Ottawa, ON K1Y 4E9, Canada
关键词
BLOOD-VOLUME; QUANTIFICATION; PERMEABILITY; EXCHANGE; LEAKAGE; TRACER; T-1;
D O I
10.3174/ajnr.A3012
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The accuracy of tumor plasma volume and K-trans estimates obtained with DCE MR imaging may have inaccuracies introduced by a poor estimation of the VIF. In this study, we evaluated the diagnostic accuracy of a novel technique by using a phase-derived VIE and "bookend" T1 measurements in the preoperative grading of patients with suspected gliomas. MATERIALS AND METHODS: This prospective study included 46 patients with a new pathologically confirmed diagnosis of gnome. Both magnitude and phase images were acquired during DCE MR imaging for estimates of K-trans_phi and V-p_phi (calculated from a phase-derived VIF and bookend T1 measurements) as well as K-trans_SI and V-p_SI (calculated from a magnitude-derived VIF without T1 measurements). RESULTS: Median K-trans_phi values were 0.0041 minutes(-1) (95% CI, 0.00062-0.033), 0.031 minutes(-1) (0.011-0.150), and 0.088 minutes(-1) (0.069-0.110) for grade II, III, and IV gliomas, respectively (P <= .05 for each). Median V-p_phi values were 0.64 mL/100 g (0.06-1.40), 0.98 mL/100 g (0.34-2.20), and 2.16 mL/100 g (1.8-3.1) with P = .15 between grade II and III gliomas and P = .015 between grade III and IV gliomas. In differentiating low-grade from high-grade gliomas, AUCs for K-trans_phi, V-p_phi K-trans_SI, and V-p_SI were 0.87 (0.73-1), 0.84 (0.69-0.98), 0.81 (0.59.1), and 0.84 (0.66-0.91). The differences between the AUCs were not statistically significant. CONCLUSIONS: K-trans_phi and V-p_phi are parameters that can help in differentiating low-grade from high-grade gliomas.
引用
收藏
页码:1539 / 1545
页数:7
相关论文
共 50 条
  • [1] Comparison of the Diagnostic Accuracy of DSC- and Dynamic Contrast-Enhanced MRI in the Preoperative Grading of Astrocytomas
    Nguyen, T. B.
    Cron, G. O.
    Perdrizet, K.
    Bezzina, K.
    Torres, C. H.
    Chakraborty, S.
    Woulfe, J.
    Jansen, G. H.
    Sinclair, J.
    Thornhill, R. E.
    Foottit, C.
    Zanette, B.
    Cameron, I. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (11) : 2017 - 2022
  • [2] Diagnostic value of preoperative contrast-enhanced MR imaging of the breast
    Winnekendonk, G
    Krug, B
    Warm, M
    Göhring, UJ
    Mallmann, P
    Lackner, K
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (05): : 688 - 693
  • [3] Assessment of Renal Function with Dynamic Contrast-Enhanced MR Imaging
    Bokacheva, Louisa
    Rusinek, Henry
    Zhang, Jeff L.
    Lee, Vivian S.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2008, 16 (04) : 597 - +
  • [4] Accuracy of dynamic contrast-enhanced MR imaging in patients with indeterminate mammograms
    Imbriaco, M
    Sodano, A
    Riccardi, A
    Del Vecchio, S
    Panza, M
    Limite, G
    Pace, U
    Forestieri, P
    Petrella, M
    Salvatore, G
    EUROPEAN JOURNAL OF CANCER, 1998, 34 : S73 - S73
  • [5] Dynamic Contrast-Enhanced Perfusion MRI and Diffusion-Weighted Imaging in Grading of Gliomas
    Arevalo-Perez, Julio
    Peck, Kyung K.
    Young, Robert J.
    Holodny, Andrei I.
    Karimi, Sasan
    Lyo, John K.
    JOURNAL OF NEUROIMAGING, 2015, 25 (05) : 792 - 798
  • [6] Automatic selection of arterial input function on dynamic contrast-enhanced MR images
    Peruzzo, Denis
    Bertoldo, Alessandra
    Zanderigo, Francesca
    Cobelli, Claudio
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2011, 104 (03) : E148 - E157
  • [7] Effects of artery input function on dynamic contrast-enhanced MRI for determining grades of gliomas
    Jia, Lin
    Wu, Xia
    Wan, Qian
    Wan, Liwen
    Jia, Wenxiao
    Zhang, Na
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1119):
  • [8] The Accuracy of Renal Function Measurements in Obstructive Hydronephrosis Using Dynamic Contrast-Enhanced MR Renography
    Wang, Yuan-Cheng
    Chang, Di
    Zhang, Shi-Jun
    Wang, Qiang
    Ju, Shenghong
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (04) : 859 - 866
  • [9] Optimized Preload Leakage-Correction Methods to Improve the Diagnostic Accuracy of Dynamic Susceptibility-Weighted Contrast-Enhanced Perfusion MR Imaging in Posttreatment Gliomas
    Hu, L. S.
    Baxter, L. C.
    Pinnaduwage, D. S.
    Paine, T. L.
    Karis, J. P.
    Feuerstein, B. G.
    Schmainda, K. M.
    Dueck, A. C.
    Debbins, J.
    Smith, K. A.
    Nakaji, P.
    Eschbacher, J. M.
    Coons, S. W.
    Heiserman, J. E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (01) : 40 - 48
  • [10] Assessment of cerebral hemodynamics in subcortical vascular encephalopathy by using dynamic susceptibility contrast-enhanced MR imaging
    Neff, KW
    Gueckel, F
    Schwartz, A
    Georgi, M
    RADIOLOGY, 1996, 201 : 14 - 14