Highly sensitive investigation of sirolimus by development of an ion-sensitive field effect transistor based on NH2-MIL-53(Fe)

被引:0
|
作者
Nemati, Seyed Saman [1 ]
Seresht, Mohammad Hosein Salemi [2 ]
Dehghan, Gholamreza [1 ]
Abdi, Yaser [2 ]
机构
[1] Univ Tabriz, Fac Nat Sci, Dept Biol, Lab Biochem & Mol Biol, Tabriz 5166616471, Iran
[2] Univ Tehran, Dept Phys, Nanophys Res Lab, Tehran 1439955961, Iran
关键词
Sensor; Sirolimus; NH 2-MIL-53(Fe); Ion-sensitive field-effect transistor; Electrochemistry; LIQUID-CHROMATOGRAPHY; MAMMALIAN TARGET; RAPAMYCIN; BLOOD; MTOR;
D O I
10.1016/j.sna.2024.116141
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Sirolimus (Sir) is widely used in organ transplant patients because it inhibits the mechanistic target of rapamycin (mTOR) activity and suppresses the immune system. In addition, Sir affects translation, biological processes, as well as various other cell signaling pathways. Therefore, it is essential to determine its systemic concentration clinically. However, determining Sir concentration using optical, chromatographic, and mass spectrometry techniques is expensive, time-consuming, and technically challenging. Here, we used an ISFET-based electrochemical sensor, based on the NH2-MIL-53(Fe) sensing layer, to detect Sir. NH2-MIL-53(Fe) to iron and amine active functional groups is quickly immobilized on the surface of ISFET with a ZnO-sensitive layer. It detects Sir using adsorption, redox process, and high electron transfer ability. The proposed sensor detected Sir with LOD and LOQ 33.8 nM and 102.43 nM, respectively. In addition, it had a high sensitivity of 80.109 mu A.nM- 1 and 28.688 mu A.nM- 1, respectively in buffer and urine. Also, this sensor had reproducibility of results with RSD 2.79 % and reusability in seven consecutive days (76.93-100 % recovery). The NH2-MIL-53(Fe)/ZnO@ISFET is proposed as a cheap, miniaturizable, high-sensitivity real-time sensing method.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Wireless in vivo recording of cortical activity by an ion-sensitive field effect transistor
    Bhatt, Suyash
    Masterson, Emily
    Zhu, Tianxiang
    Eizadi, Jenna
    George, Judy
    Graupe, Nesya
    Vareberg, Adam
    Phillips, Jack
    Bok, Ilhan
    Dwyer, Matthew
    Ashtiani, Alireza
    Hai, Aviad
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 382
  • [32] IMPROVEMENT OF STRUCTURAL INSTABILITY OF THE ION-SENSITIVE FIELD-EFFECT TRANSISTOR (ISFET)
    CHEN, KM
    LI, GH
    CHEN, LX
    ZHU, Y
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) : 209 - 211
  • [33] Autonomous in situ calibration of ion-sensitive field effect transistor pH sensors
    Bresnahan, Philip J.
    Takeshita, Yuichiro
    Wirth, Taylor
    Martz, Todd R.
    Cyronak, Tyler
    Albright, Rebecca
    Wolfe, Kennedy
    Warren, Joseph K.
    Mertz, Keaton
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2021, 19 (02): : 132 - 144
  • [34] Intrinsic hydrogen-terminated diamond as ion-sensitive field effect transistor
    Rezek, B.
    Shin, D.
    Watanabe, H.
    Nebel, C. E.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (02) : 596 - 599
  • [35] Ascorbic acid determination with an ion-sensitive field effect transistor-based peroxidase biosensor
    Volotovsky, V
    Kim, N
    ANALYTICA CHIMICA ACTA, 1998, 359 (1-2) : 143 - 148
  • [36] A numerical simulation tool for nanoscale ion-sensitive field-effect transistor
    Abdolkader, Tarek M.
    INTERNATIONAL JOURNAL OF NUMERICAL MODELLING-ELECTRONIC NETWORKS DEVICES AND FIELDS, 2016, 29 (06) : 1118 - 1128
  • [37] Biomimetic sensor for cAMP using an ion-sensitive field-effect transistor
    Kugimiya, Akimitsu
    Kohara, Kaori
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (03): : 959 - 962
  • [38] THE ION-SENSITIVE FIELD-EFFECT TRANSISTOR - A SEMICONDUCTOR SENSOR FOR CHEMICAL QUANTITIES
    KLEIN, M
    KUISL, M
    RICKER, T
    TECHNISCHES MESSEN, 1983, 50 (10): : 381 - 388
  • [39] A Novel Electrical Circuit Model for Ion-Sensitive Field-Effect Transistor
    da Silva, Luciano Lourenco F.
    de Moraes Cruz, Carlos Augusto
    de Souza, Jair Fernandes
    Cardoso, Valtemar Fernandes
    Pelegrini, Marcus Vinicius
    2017 2ND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SYSTEMS, CIRCUITS AND TRANSDUCERS (INSCIT), 2017, : 64 - 68
  • [40] Development of an Electrochemical Sensor for Chloride ion Detection Using Ion-Sensitive Field-Effect Transistor Array
    Yuan, Xinxin
    Zhang, Xuelian
    Huang, Yizheng
    Jie, Junyao
    Wei, Qingquan
    Tan, Manqing
    Yu, Yude
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (01): : 1 - 11