Potential of Near-Infrared Optical Techniques for Non-invasive Blood Glucose Measurement: A Pilot Study

被引:0
|
作者
Fathimal, M. Sameera [1 ]
Kumar, Janardanan Subramonia [2 ]
Prabha, A. Jeya [1 ]
Selvaraj, Jothiraj [1 ]
Shilparani, F. Fabiola Jemmie [1 ]
Kirubha, S. P. Angeline [1 ]
机构
[1] SRM Inst Sci & Technol, Coll Engn & Technol, Dept Biomed Engn, Kattankulathur 603203, Tamil Nadu, India
[2] SRM Inst Sci & Technol, SRM Med Coll Hosp & Res Ctr, Dept Gen Med, Kattankulathur 603203, Tamil Nadu, India
关键词
Diabetes mellitus; Glucose monitoring; Non-invasive method; Near-infrared wavelength; Optical device; TISSUE; SPECTROSCOPY;
D O I
10.1016/j.irbm.2024.100870
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Diabetes mellitus manifested by escalated blood glucose, demands periodic or continuous glucose monitoring in the pursuit of improved control, optimal management, and appropriate medication. The existing state-of-the-art for blood glucose estimation are invasive methodologies necessitating the acquisition of blood sample through either a finger-stick or venipuncture. Methods: We propose a dual Near-infrared wavelength integrated in a 3D printed enclosure as the optical prototype for non-invasive glucose estimation. We acquired data from both diabetic and healthy subjects with the developed system and subsequently validated the system. Results: The system demonstrated commendable clinical accuracy, as evidenced by the alignment of data pairs representing actual blood glucose levels and blood glucose levels predicted by our optical system within the A+B zones of the Parkes error grid and zones of no-risk and lower risk as defined by the surveillance error grid. We achieved compliant pairs percentage of 95.6%, which satisfies the accuracy requirements of the blood glucose monitoring surveillance study. The mean absolute percentage error attained with the proposed device (5.99%) was significant in predicting the blood glucose. Conclusion: We successfully deployed the NIR wavelengths functionality as the promising approach for glucose monitoring, offering new possibilities for improved medical interventions. (c) 2024 AGBM. Published by Elsevier Masson SAS. All rights are reserved, including those for text and
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Non-invasive blood glucose measurement Application of near infrared optical measurement
    Anas, M. N.
    Syafirah, A.
    Norali, A. N.
    Normahira, M.
    2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT), 2012, : 258 - 261
  • [2] Extraction of glucose information in blood glucose measurement by non-invasive near-infrared spectra
    Liu, R
    Chen, WL
    Gu, XY
    Luo, YH
    Xu, KX
    OPTICAL DIAGNOSTICS AND SENSING V, 2005, 5702 : 30 - 38
  • [3] Non-invasive Blood Glucose Measurement Scheme Based on Near-infrared Spectroscopy
    Wang Shulei
    Yuan Xueguang
    Zhang Yangan
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
  • [4] Determination of the reference position in the near-infrared non-invasive blood glucose measurement in vivo
    Han, Guang
    Liu, Jin
    Liu, Rong
    Xu, Kexin
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VII, 2017, 0024
  • [5] Near-infrared LED based Non-invasive Blood Glucose Sensor
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    2014 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND INTEGRATED NETWORKS (SPIN), 2014, : 591 - 594
  • [6] Design a Non-invasive Near-Infrared LED Blood Glucose Sensor
    Lai, Jui-Lin
    Huang, Shin-Yi
    Lin, Rong-Sheng
    Tsai, Shin-Chia
    PROCEEDINGS OF 2016 INTERNATIONAL CONFERENCE ON APPLIED SYSTEM INNOVATION (ICASI), 2016,
  • [7] Non-Invasive Measurement of Blood Glucose Biomimetics with the Reflectance Method on Near-Infrared Light Source
    Alatas, Husin
    Prastowo, Bayu
    Jenie, Renan Prasta
    Dahrul, Muhammad
    Hardyanto, Ichsan
    Iskandar, Johan
    Kurniawan, Ade
    Siskandar, Ridwan
    Nurdin, Naufal Muharram
    Suryana, Yaya
    Pambudi, Sabar
    Widayanti, Tika
    Aridarma, Arga
    Rahayu, Maria Sri Kristina
    Riadhie, Titah Sihdjati
    Irzaman
    9TH NATIONAL PHYSICS SEMINAR 2020, 2021, 2320
  • [8] Simulation of the Effect of Dermal Thickness on Non-Invasive Blood Glucose Measurement by Near-Infrared Spectroscopy
    Liu Wen-bo
    Liu Jin
    Han Tong-shuai
    Ge Qing
    Liu Rong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43 (09) : 2699 - 2704
  • [9] Investigation on how to choose measurement sites for non-invasive near-infrared blood glucose sensing
    Jiang, Jingying
    Zou, Da
    Min, Xiaolin
    Ma, Zhenhe
    Xu, Kexin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IX, 2012, 8222
  • [10] Preliminary study of mechanism of non-invasive blood glucose measurement based on near-infrared diffuse reflectance spectroscopy
    Chen, WL
    Liu, R
    Luo, YH
    Han, YH
    Xu, KX
    Complex Dynamics and Fluctuations in Biomedical Photonics II, 2005, 5696 : 91 - 100