Dimensional accuracy and clinical adaptation of monolithic zirconia crowns fabricated with the nanoparticle jetting technique

被引:8
|
作者
Lyu, Jizhe [1 ,2 ,3 ,4 ]
Yang, Xu [1 ]
Li, Yi [1 ]
Tan, Jianguo [1 ]
Liu, Xiaoqiang [1 ,2 ,3 ,4 ]
机构
[1] Peking Univ, Sch & Hosp Stomatol, Dept Prosthodont, 22 Zhongguancun Ave South, Beijing 100081, Peoples R China
[2] Peking Univ, Natl Ctr Stomatol, Beijing, Peoples R China
[3] Peking Univ, Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[4] Peking Univ, Natl Engn Res Ctr Oral Biomat & Digital Med Device, Beijing, Peoples R China
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 132卷 / 05期
关键词
MARGIN QUALITY; TECHNOLOGY; SYSTEM; LOAD; FIT;
D O I
10.1016/j.prosdent.2023.04.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The nanoparticle jetting (NPJ) technique is a recently developed additive manufacturing method that may have useful dental applications. The manufacturing accuracy and clinical adaptation of zirconia monolithic crowns fabricated with NPJ are unknown. Purpose. The purpose of this in vitro study was to compare the dimensional accuracy and clinical adaptation of zirconia crowns fabricated with NPJ and those fabricated with subtractive manufacturing (SM) and digital light processing (DLP). Material and methods. Five standardized typodont right mandibular first molars were prepared for ceramic complete crowns, and 30 zirconia monolithic crowns were fabricated using SM, DLP, and NPJ (n=10) with a completely digital workflow. The dimensional accuracy at the external, intaglio, and marginal areas was determined by superimposing the scanned data and computer-aided design data of the crowns (n=10). Occlusal, axial, and marginal adaptations were evaluated by using a nondestructive silicone replica and dual scanning method. The 3dimensional discrepancy was evaluated to determine clinical adaptation. Differences among test groups were analyzed by using a MANOVA and the post hoc least significant difference test for normally distributed data or the Kruskal-Wallis test with Bonferroni correction for nonnormally distributed data (a=.05). Results. Significant differences were found in the dimensional accuracy and clinical adaptation among the groups (P<.001). The NPJ group had a lower overall root mean square (RMS) value for dimensional accuracy (22.9 +/- 1.4 <mu> m) than the SM (27.3 +/- 5.0 mu m) and DLP (36.4 +/- 5.9 mu m) groups (P<.001). The NPJ group had a lower external RMS value (23.0 +/- 3.0 <mu> m) than the SM group (28.9 +/- 5.4 mu m) (P<.001) and equivalent marginal and intaglio RMS values than the SM group. The DLP group had larger external (33.3 +/- 4.3 <mu> m), intaglio (36.1 +/- 10.7 mu m), and marginal (79.4 +/- 12.9 mu m) deviations than the NPJ and SM groups (P<.001). With regard to clinical adaptation, the marginal discrepancy was smaller in the NPJ group (63.9 +/- 27.3 <mu> m) than in the SM group (70.8 +/- 27.5 mu m) (P<.001). No significant differences were found between the SM and NPJ groups in terms of the occlusal (87.2 +/- 25.5 and 80.5 +/- 24.2 <mu> m, respectively) and axial (39.1 +/- 19.7 and 38.4 +/- 13.7 mu m, respectively) discrepancies. The DLP group had larger occlusal (239.0 +/- 60.1 mu m), axial (84.9 +/- 29.1 mu m), and marginal (140.4 +/- 84.3 mu m) discrepancies than the NPJ and SM groups (P<.001). Conclusions. Monolithic zirconia crowns fabricated using NPJ have higher dimensional accuracy and clinical adaptation than those fabricated using SM or DLP. (J Prosthet Dent 2024;132:985.e1-e7)
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Clinical outcomes of implant-supported monolithic zirconia crowns and fixed partial dentures: A systematic review
    Kim, Wanjin
    Li, Xiao Chun
    Bidra, Avinash S.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (02): : 102 - 107
  • [42] Marginal and Internal Fit of Monolithic Zirconia Crowns Fabricated by Using Two Different CAD-CAM Workflows: An In Vitro Study
    Cin, Vahap
    Izgi, Ayca Deniz
    Kale, Ediz
    Yilmaz, Burak
    PROSTHESIS, 2023, 5 (01): : 35 - 47
  • [43] The clinical accuracy of single crowns exclusively fabricated by digital workflow—the comparison of two systems
    Petya K. Brawek
    Stefan Wolfart
    Lutz Endres
    Armin Kirsten
    Sven Reich
    Clinical Oral Investigations, 2013, 17 : 2119 - 2125
  • [44] Randomized controlled clinical trial of wear characteristics of Cad/Cam lithium silicate versus monolithic zirconia crowns
    Salem, R. M.
    Taymour, M.
    El Naggar, G.
    JOURNAL OF OSSEOINTEGRATION, 2023, 15 (03) : 181 - 188
  • [45] Clinical evaluation of cemented and adhesively resin-bonded monolithic and partially layered zirconia and lithium disilicate crowns
    Alraheam, Islam Abd
    Al-Asmar, Aya
    Hasan, Noor
    Asoleihat, Firas
    Alkayed, Awni
    SAUDI DENTAL JOURNAL, 2023, 35 (05) : 508 - 514
  • [46] The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems
    Brawek, Petya K.
    Wolfart, Stefan
    Endres, Lutz
    Kirsten, Armin
    Reich, Sven
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (09) : 2119 - 2125
  • [47] Accuracy and adaptation of one-piece endodontic crowns fabricated through 3D printing and milling
    Xiao, Ping
    Zheng, Ziting
    Zhang, Yanli
    Zeng, Yuting
    Yan, Wenjuan
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (02): : 422 - 433
  • [48] Fitting accuracy of zirconia single crowns produced via digital and conventional impressions—a clinical comparative study
    Matthias Rödiger
    Arthur Heinitz
    Ralf Bürgers
    Sven Rinke
    Clinical Oral Investigations, 2017, 21 : 579 - 587
  • [49] Prospective study of monolithic zirconia crowns: clinical behavior and survival rate at a 5-year follow-up
    Fernanda Sola-Ruiz, Ma
    Baixauli-Lopez, Mar
    Roig-Vanaclocha, Ana
    Amengual-Lorenzo, Jose
    Agustin-Panadero, Ruben
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (03) : 284 - 290
  • [50] Five-year clinical performance of monolithic and partially veneered zirconia single crowns-a prospective observational study
    Waldecker, Moritz
    Behnisch, Rouven
    Rammelsberg, Peter
    Boemicke, Wolfgang
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 339 - 345