Dimensional accuracy and clinical adaptation of monolithic zirconia crowns fabricated with the nanoparticle jetting technique

被引:8
|
作者
Lyu, Jizhe [1 ,2 ,3 ,4 ]
Yang, Xu [1 ]
Li, Yi [1 ]
Tan, Jianguo [1 ]
Liu, Xiaoqiang [1 ,2 ,3 ,4 ]
机构
[1] Peking Univ, Sch & Hosp Stomatol, Dept Prosthodont, 22 Zhongguancun Ave South, Beijing 100081, Peoples R China
[2] Peking Univ, Natl Ctr Stomatol, Beijing, Peoples R China
[3] Peking Univ, Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[4] Peking Univ, Natl Engn Res Ctr Oral Biomat & Digital Med Device, Beijing, Peoples R China
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 132卷 / 05期
关键词
MARGIN QUALITY; TECHNOLOGY; SYSTEM; LOAD; FIT;
D O I
10.1016/j.prosdent.2023.04.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The nanoparticle jetting (NPJ) technique is a recently developed additive manufacturing method that may have useful dental applications. The manufacturing accuracy and clinical adaptation of zirconia monolithic crowns fabricated with NPJ are unknown. Purpose. The purpose of this in vitro study was to compare the dimensional accuracy and clinical adaptation of zirconia crowns fabricated with NPJ and those fabricated with subtractive manufacturing (SM) and digital light processing (DLP). Material and methods. Five standardized typodont right mandibular first molars were prepared for ceramic complete crowns, and 30 zirconia monolithic crowns were fabricated using SM, DLP, and NPJ (n=10) with a completely digital workflow. The dimensional accuracy at the external, intaglio, and marginal areas was determined by superimposing the scanned data and computer-aided design data of the crowns (n=10). Occlusal, axial, and marginal adaptations were evaluated by using a nondestructive silicone replica and dual scanning method. The 3dimensional discrepancy was evaluated to determine clinical adaptation. Differences among test groups were analyzed by using a MANOVA and the post hoc least significant difference test for normally distributed data or the Kruskal-Wallis test with Bonferroni correction for nonnormally distributed data (a=.05). Results. Significant differences were found in the dimensional accuracy and clinical adaptation among the groups (P<.001). The NPJ group had a lower overall root mean square (RMS) value for dimensional accuracy (22.9 +/- 1.4 <mu> m) than the SM (27.3 +/- 5.0 mu m) and DLP (36.4 +/- 5.9 mu m) groups (P<.001). The NPJ group had a lower external RMS value (23.0 +/- 3.0 <mu> m) than the SM group (28.9 +/- 5.4 mu m) (P<.001) and equivalent marginal and intaglio RMS values than the SM group. The DLP group had larger external (33.3 +/- 4.3 <mu> m), intaglio (36.1 +/- 10.7 mu m), and marginal (79.4 +/- 12.9 mu m) deviations than the NPJ and SM groups (P<.001). With regard to clinical adaptation, the marginal discrepancy was smaller in the NPJ group (63.9 +/- 27.3 <mu> m) than in the SM group (70.8 +/- 27.5 mu m) (P<.001). No significant differences were found between the SM and NPJ groups in terms of the occlusal (87.2 +/- 25.5 and 80.5 +/- 24.2 <mu> m, respectively) and axial (39.1 +/- 19.7 and 38.4 +/- 13.7 mu m, respectively) discrepancies. The DLP group had larger occlusal (239.0 +/- 60.1 mu m), axial (84.9 +/- 29.1 mu m), and marginal (140.4 +/- 84.3 mu m) discrepancies than the NPJ and SM groups (P<.001). Conclusions. Monolithic zirconia crowns fabricated using NPJ have higher dimensional accuracy and clinical adaptation than those fabricated using SM or DLP. (J Prosthet Dent 2024;132:985.e1-e7)
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns
    Kale, Ediz
    Seker, Emre
    Yilmaz, Burak
    Ozcelik, Tuncer Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (06): : 890 - 895
  • [22] Clinical Evaluation of Monolithic Zirconia Crowns: A Short-Term Pilot Report
    Kitaoka, Aki
    Akatsuka, Ryo
    Kato, Hiroaki
    Yoda, Nobuhiro
    Sasaki, Keiichi
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (02) : 124 - 126
  • [23] Three-year clinical performance of posterior monolithic zirconia single crowns
    Mikeli, Aikaterini
    Walter, Michael H.
    Rau, Stefanie Anke
    Raedel, Martina
    Raedel, Michael
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (06): : 1252 - 1257
  • [24] Marginal Adaptation of Monolithic High-Translucency Versus Porcelain-Veneered Zirconia Crowns
    Rayyan, Mohammad R.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (04) : 364 - 366
  • [25] Trueness and precision of digital light processing fabricated 3D printed monolithic zirconia crowns
    Refaie, Ashraf
    Bourauel, Christoph
    Elshazly, Tarek
    Evers-Dietze, Bernd
    Alhotan, Abdulaziz
    Aldesoki, Mostafa
    JOURNAL OF DENTISTRY, 2024, 148
  • [26] Evaluation of Marginal and Internal Adaptation of Crowns Fabricated with Three Different Zirconia CAD/CAM Materials
    Temizkan Nizaroglu, R.
    Kucuk, C.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2024, 27 (01) : 54 - 61
  • [27] Evaluation of fi t and accuracy of single crowns fabricated from self-glazed zirconia compared with milled zirconia
    Marouki, Carolina
    Shamon, Assal
    Svanborg, Per
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1105 - 1110
  • [28] Randomized clinical study of wear of enamel antagonists against polished monolithic zirconia crowns
    Esquivel-Upshaw, J. F.
    Kim, M. J.
    Hsu, S. M.
    Abdulhameed, N.
    Jenkins, R.
    Neal, D.
    Ren, F.
    Clark, A. E.
    JOURNAL OF DENTISTRY, 2018, 68 : 19 - 27
  • [29] Marginal Adaptation of Different Monolithic Zirconia Crowns with Horizontal and Vertical Finishing Lines: A Comparative in Vitro Study
    Nasir, Mohammed Qasim
    Kadhim, Alaa Jawad
    JOURNAL OF PIONEERING MEDICAL SCIENCES, 2023, 12 (03): : 23 - 28
  • [30] Clinical research on restorations using CAD/CAM-fabricated monolithic zirconia endocrowns and post and core crowns after up to 5 years
    Zou, Yun
    Zhan, DeSong
    Xiang, JingZhou
    Li, Ly
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2022, 25 (03) : 287 - 294