Accuracy of freehand surgery, static and dynamic computer assisted surgery on zygomatic implant placement: A systematic review and meta-analyses

被引:1
|
作者
Traboulsi-Garet, Bassel [1 ]
Jorba-Garcia, Adria [1 ,4 ]
Bara-Casaus, Javier [1 ,2 ,3 ]
Camps-Font, Octavi [1 ,4 ]
Valmaseda-Castellon, Eduard [1 ,4 ]
Figueiredo, Rui [1 ,4 ]
Sanchez-Garces, Angels [1 ,4 ]
机构
[1] Univ Barcelona, Sch Med & Hlth Sci, Barcelona, Spain
[2] Hosp Univ Sagrat Cor, Grp Quironsalud, Dent & Maxillofacial Inst, Barcelona, Spain
[3] Univ Barcelona, Hosp Univ Mutua Terrassa, Dept Oral & Maxillofacial Surg, Terrassa, Spain
[4] IDIBELL Inst, Barcelona, Spain
关键词
Accuracy; Zygomatic implants; Arch; /; Zygomatic; Image guided surgery; Static guided surgery; TIME SURGICAL NAVIGATION; DENTAL IMPLANTS; GUIDED SURGERY; PATIENT; REHABILITATION; COMPLICATIONS; SURVIVAL;
D O I
10.1016/j.jcms.2024.12.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Real-time surgical navigation systems (dynamic computer-aided surgery, d-CAIS) and static guided surgery (static computer-aided surgery, s-CAIS) have been shown to enhance the accuracy of zygomatic implant (ZI) placement. The objective of this systematic review was to evaluate and compare the accuracy and risk of complications associated with d-CAIS and s-CAIS in ZI placement. A systematic review of published studies involving more than 4 patients was conducted to assess and compare the accuracy of d-CAIS and s-CAIS in zygomatic implant placement. Only one study included freehand ZI placement as a control. The primary outcomes measured were the accuracy of implant placement relative to preoperative planning, with a secondary focus on evaluating any potential complications. Out of 903 screened studies, 14 met the inclusion criteria. Freehand zygomatic implant placement was used as a control in only 1 study. The results revealed a mean apex deviation of 2.07 mm (95% CI: 2.01 to 2.13; I2 = 83.14%) for d-CAIS, 1.29 mm (95% CI: 1.15 to 1.43; I2 = 94.5%) for s-CAIS, and 4.98 mm (95% CI: 3.59 to 6.37; I2 = not assessable) for freehand placement. Reported complications included mucositis, reversible bilateral sinusitis, oroantral fistula, unspecified reversible postoperative complications, and fracture of the anterior wall of the zygoma. Both CAIS systems demonstrated high accuracy and safety in ZI placement, with a nearly 99% success rate at 6 months of follow-up. These findings suggest that both d-CAIS and s-CAIS are reliable methods for improving the precision and reducing the risks associated with ZI procedures.
引用
收藏
页码:301 / 311
页数:11
相关论文
共 50 条
  • [41] Comparison of the accuracy of implant placement using a simple guide device and freehand surgery
    Kim, Yu-Jin
    Kim, Jungeun
    Lee, Jae-Rim
    Kim, Hee-Sun
    Sim, Hye-Young
    Lee, Ho
    Han, Yoon-Sic
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (04) : 2256 - 2261
  • [42] A systematic review of meta-analyses in orthopaedic surgery between 2000 and 2016
    Manta, A.
    Opingari, E.
    Simunovic, N.
    Duong, A.
    Sprague, S.
    Peterson, D.
    Bhandari, M.
    BONE & JOINT JOURNAL, 2018, 100B (10): : 1270 - 1274
  • [43] Seizure outcome of pediatric epilepsy surgery: Systematic review and meta-analyses
    Widjaja, Elysa
    Jain, Puneet
    Demoe, Lindsay
    Guttmann, Astrid
    Tomlinson, George
    Sander, Beate
    NEUROLOGY, 2020, 94 (07) : 311 - 321
  • [44] The effect of bariatric surgery on periodontal health: systematic review and meta-analyses
    Colak, Dejana
    Gaspersic, Rok
    Kucic, Alja Cmok
    Pintar, Tadeja
    Gaspirc, Boris
    ARCHIVES OF MEDICAL SCIENCE, 2021, 17 (04) : 1118 - 1127
  • [45] 136 Intraoperative Neuromonitoring in Spinal Surgery: A Systematic Review and Meta-Analyses
    Ang, W. W.
    Boutong, S.
    Shetty, N.
    BRITISH JOURNAL OF SURGERY, 2021, 108 (SUPPL 2)
  • [46] Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies
    Bover-Ramos, Fernando
    Vina-Almunia, Jose
    Cervera-Ballester, Juan
    Penarrocha-Diago, Miguel
    Garcia-Mira, Berta
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) : 101 - 115
  • [47] Accuracy of keyless vs drill-key implant systems for static computer-assisted implant surgery using two guide-hole designs compared to freehand implant placement: an in vitro study
    Clemens Raabe
    Tabea S. Schuetz
    Vivianne Chappuis
    Burak Yilmaz
    Samir Abou-Ayash
    Emilio Couso-Queiruga
    International Journal of Implant Dentistry, 9
  • [48] Accuracy of keyless vs drill-key implant systems for static computer-assisted implant surgery using two guide-hole designs compared to freehand implant placement: an in vitro study
    Raabe, Clemens
    Schuetz, Tabea S.
    Chappuis, Vivianne
    Yilmaz, Burak
    Abou-Ayash, Samir
    Couso-Queiruga, Emilio
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01) : 4
  • [49] Influence of implant macrodesign and insertion connection technology on the accuracy of static computer-assisted implant surgery
    El Kholy, Karim
    Ebenezer, Supriya
    Wittneben, Julia-Gabriela
    Lazarin, Rafael
    Rousson, Dominique
    Buser, Daniel
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) : 1073 - 1079
  • [50] The Impact of Surgical Guide Fixation and Implant Location on Accuracy of Static Computer-Assisted Implant Surgery
    Pessoa, Roberto
    Siqueira, Rafael
    Li, Junying
    Saleh, Islam
    Meneghetti, Priscila
    Bezerra, Fabio
    Wang, Hom-Lay
    Mendonca, Gustavo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (02): : 155 - 164